Take smooth performance to the next level with the wide power range and functionality of ACS150. Available in both single and three phase supplies. Many functions are standard, such as PID control, a built-in brake chopper and EMC filter. An optional FlashDrop drive configuration tool makes configuring unpowered drives quick and easy. 

Highlights

  • Power range 0.37 to 4 kW/0.5 to 5 Hp
  • IP20 enclosure
  • Scalar control
  • Integrated user interface and potentiometer
  • Built-in brake chopper
  • Built-in EMC filter for 2nd environment

ABB ACS150 Micro Drives Catalog

ABB ACS150 Micro Drives Technical Catalog

ABB ACS150 Micro Drives User Manual

See all ACS150 Configurations and Options Here - Online Purchase Available

0.5 - 3 HP (1~230V In/ 3~230V Out)      0.5 - 3 HP (3~230V In/3~230V Out)         0.5 - 5 HP (3~460V In/3~460V Out)
Input ratings Input voltage range 200 - 240VAC; 380 - 480VAC
  Input voltage tolerance 10% / -10%
  Phase 1-phase 230 V, 3-phase 230/460 V
  Frequency 48 to 63Hz, maximum rate of change 17% / second
  Short circuit rating (UL 508c) 100,000 rms symmetrical amperes up to 600V when input cables protected by class T fuses or similar type fuse.
65,000 rms symmetrical amperes up to 460V when input cables protected by ABB MS series Multiple Motor Protector
Output ratings Horsepower 0.5 - 3 HP @ 230 VAC, 1 Ph
0.5 - 3 HP @ 230 VAC, 3 Ph
0.5 - 5 HP @ 460 VAC, 3 Ph
  Overload capacity 150% overload capacity for up to 1 minute
  Frequency 0-500 Hz
  Voltage 0 to maximum input voltage
  Motor types Asynchronous AC induction motors
Protective features Overcurrent Over-current trip limit up to 325%
  DC bus overvoltage 130% of input voltage
  Drive Overtemp Heatsink monitor (90°C / 203°F)
  Output short circuit Phase-to-phase on drive output
  Undervoltage 65% of input voltage
  Loss of reference Trips on loss of speed command signal
  Motor overtemp Protected (I2t)
  Loss of control panel Drive will trip if under control panel control and communication is lost
  Motor stall Motor cannot achieve commanded speed due to excessive load
  Ground fault Ground fault detected in motor or motor cables
  Motor phase fault Loss at one of the motor phases
Environmental Temperature -10°C (14°F) to 40°C (104°F) - up to 50°C with 10% derate
  Cooling R0 frame convection, R1-R2 forced air
  Enclosure Standard IP20, Option kit UL Type 1 (IP21)
  Altitude 1,000 m (3,300 ft.).  Derate by 1% every 100 m (328 ft.) up to 2,000m (6,600 ft.)
  Humidity 0% to 95%, non-condensing
  Vibration 2…9 Hz, 3.0 mm (0.12 in)/9…200 Hz, 10 m/s2 (33 ft/s2)
Keypad display Display LCD Graphical Display
  Keys 8 key keypad (2-soft keys) with tactile response and analog speed potentiometer
  Functions Output status monitoring, digital and analog speed control, parameter setting and display, diagnostic and fault log display, motor run, local/remote toggle
  Remote mount  N/A
  Trip Last three faults stored in fault history
Control specifications Switching frequency 4-16 kHz (4 kHz default)
  Accel/decel Two independently adjustable sets of speed ramps - 0-1800 Seconds 
  Speed control accuracy N.A. -  V/Hz drive
  Skip frequencies Three configurable bands 0 to maximum frequency
  PC setup software MFDT-01 FlashDrop
  Maximum output frequency 500 Hz
  Selectable operating modes 2-wire, 3-wire, Alternate, Motor Pot, Hand/Auto, PID Control, FlashDrop set, user sets
Analog inputs One 0-10VDC or 0/4 - 20maDC
  Resolution 11 bit + sign
Digital inputs Five programmable (4) Digital Inputs (1) pulse train input (DI5 can be used as DI or pulse train input)
  Input impedance PNP & NPN, 12-24VDC, (10V logic 0), Pulse train 0 to 16kHz, 2.4KΩ
Digital outputs One relay outputs Form C (NO + NC)
  Maximum switching voltage 250 V AC / 30 V DC
  Maximum continuous current 2 A rms