Description
Take smooth performance to the next level with the wide power range and functionality of ACS150. Available in both single and three phase supplies. Many functions are standard, such as PID control, a built-in brake chopper and EMC filter. An optional FlashDrop drive configuration tool makes configuring unpowered drives quick and easy.
Highlights
- Power range 0.37 to 4 kW/0.5 to 5 Hp
- IP20 enclosure
- Scalar control
- Integrated user interface and potentiometer
- Built-in brake chopper
- Built-in EMC filter for 2nd environment
ABB ACS150 Micro Drives Catalog
ABB ACS150 Micro Drives Technical Catalog
ABB ACS150 Micro Drives User Manual
See all ACS150 Configurations and Options Here - Online Purchase Available
0.5 - 3 HP (1~230V In/ 3~230V Out) 0.5 - 3 HP (3~230V In/3~230V Out) 0.5 - 5 HP (3~460V In/3~460V Out) | ||
Input ratings | Input voltage range | 200 - 240VAC; 380 - 480VAC |
Input voltage tolerance | 10% / -10% | |
Phase | 1-phase 230 V, 3-phase 230/460 V | |
Frequency | 48 to 63Hz, maximum rate of change 17% / second | |
Short circuit rating (UL 508c) | 100,000 rms symmetrical amperes up to 600V when input cables protected by class T fuses or similar type fuse. 65,000 rms symmetrical amperes up to 460V when input cables protected by ABB MS series Multiple Motor Protector | |
Output ratings | Horsepower | 0.5 - 3 HP @ 230 VAC, 1 Ph 0.5 - 3 HP @ 230 VAC, 3 Ph 0.5 - 5 HP @ 460 VAC, 3 Ph |
Overload capacity | 150% overload capacity for up to 1 minute | |
Frequency | 0-500 Hz | |
Voltage | 0 to maximum input voltage | |
Motor types | Asynchronous AC induction motors | |
Protective features | Overcurrent | Over-current trip limit up to 325% |
DC bus overvoltage | 130% of input voltage | |
Drive Overtemp | Heatsink monitor (90°C / 203°F) | |
Output short circuit | Phase-to-phase on drive output | |
Undervoltage | 65% of input voltage | |
Loss of reference | Trips on loss of speed command signal | |
Motor overtemp | Protected (I2t) | |
Loss of control panel | Drive will trip if under control panel control and communication is lost | |
Motor stall | Motor cannot achieve commanded speed due to excessive load | |
Ground fault | Ground fault detected in motor or motor cables | |
Motor phase fault | Loss at one of the motor phases | |
Environmental | Temperature | -10°C (14°F) to 40°C (104°F) - up to 50°C with 10% derate |
Cooling | R0 frame convection, R1-R2 forced air | |
Enclosure | Standard IP20, Option kit UL Type 1 (IP21) | |
Altitude | 1,000 m (3,300 ft.). Derate by 1% every 100 m (328 ft.) up to 2,000m (6,600 ft.) | |
Humidity | 0% to 95%, non-condensing | |
Vibration | 2…9 Hz, 3.0 mm (0.12 in)/9…200 Hz, 10 m/s2 (33 ft/s2) | |
Keypad display | Display | LCD Graphical Display |
Keys | 8 key keypad (2-soft keys) with tactile response and analog speed potentiometer | |
Functions | Output status monitoring, digital and analog speed control, parameter setting and display, diagnostic and fault log display, motor run, local/remote toggle | |
Remote mount | N/A | |
Trip | Last three faults stored in fault history | |
Control specifications | Switching frequency | 4-16 kHz (4 kHz default) |
Accel/decel | Two independently adjustable sets of speed ramps - 0-1800 Seconds | |
Speed control accuracy | N.A. - V/Hz drive | |
Skip frequencies | Three configurable bands 0 to maximum frequency | |
PC setup software | MFDT-01 FlashDrop | |
Maximum output frequency | 500 Hz | |
Selectable operating modes | 2-wire, 3-wire, Alternate, Motor Pot, Hand/Auto, PID Control, FlashDrop set, user sets | |
Analog inputs | One | 0-10VDC or 0/4 - 20maDC |
Resolution | 11 bit + sign | |
Digital inputs | Five programmable | (4) Digital Inputs (1) pulse train input (DI5 can be used as DI or pulse train input) |
Input impedance | PNP & NPN, 12-24VDC, (10V logic 0), Pulse train 0 to 16kHz, 2.4KΩ | |
Digital outputs | One relay outputs | Form C (NO + NC) |
Maximum switching voltage | 250 V AC / 30 V DC | |
Maximum continuous current | 2 A rms |