ABB Jokab Machine Safety: How DYNlink, Pluto, Vital, and Sentry Fit Together

Posted by Automation Distribution Staff on Oct 15th 2026

ABB Jokab Machine Safety: How DYNlink, Pluto, Vital, and Sentry Fit Together

ABB Jokab machine safety is built around one idea: reach Performance Level e with fewer inputs, less wiring, and faster fault finding than a conventional dual-channel design. This guide walks through how the ABB Jokab DYNlink signal works, how to choose between a Sentry safety relay, a Vital safety controller, and a Pluto safety PLC, and which ABB Jokab devices go on the machine.

What is ABB Jokab Safety?

ABB Jokab Safety is ABB's machine safety product line. It traces back to Jokab Safety, founded in Sweden in 1988 to develop products and solutions for machine safety and now part of ABB. The portfolio covers the complete safety chain: safety logic (Pluto safety PLCs, Vital safety controllers, Sentry safety relays), guard monitoring (Eden non-contact sensors, MKey and Magne switches and locks), optical safety (Orion safety light curtains), and operator devices (Smile emergency stops, JSHD4 enabling devices, Safeball two-hand controls, and pressure-sensitive mats and edges).

What separates ABB Jokab from a parts catalog is that the devices are designed to work as a system. Sensors, adapters, and controllers share the DYNlink dynamic signal, so a safety circuit can be designed, verified against EN ISO 13849-1 and IEC 62061, and later modified without rewiring the cabinet.

How does ABB Jokab DYNlink work?

DYNlink is a single-channel dynamic safety signal. Instead of holding two static 24 VDC channels high and cross-checking them, the safety controller sends a continuously changing pulse train through the safety devices and checks the pattern that comes back. Each DYNlink device processes the signal and passes it on. The signal is checked 200 times per second, so a stuck-high or stuck-low condition, a short to another conductor, or an opened guard breaks the expected pattern, and the controller drops its safety outputs. A fault such as a short circuit is detected before the affected safety device is even used.

Because the diagnostics come from the changing signal rather than from comparing two channels, one input can carry many devices. Correctly wired, up to 10 DYNlink devices on a single Pluto input reach up to PL e, Category 4, SIL 3, and a Vital safety controller supports up to 30 safety devices in series at PL e.

How do conventional safety devices join a DYNlink circuit?

Through Tina adapters. A Tina unit converts a contact-based or OSSD device, such as an emergency stop, a mechanical interlock, or a light curtain, into a DYNlink node. The ABB Jokab Tina 3A DYNlink adapter (2TLA020054R0200) is a typical example. Pluto also accepts traditional dual-channel devices directly, so a mixed installation is fine.

Sentry, Vital, or Pluto: which ABB Jokab safety logic fits the machine?

Choose by the number of safety functions and how much logic sits between them. A Sentry safety relay fits one or two simple functions, a Vital controller fits many devices that all stop the same hazard, and a Pluto safety PLC fits multiple zones, conditional logic, or a networked line.

Safety logic Best fit Configuration Scaling
Sentry safety relay One safety function per relay: an e-stop, a gate, a light curtain, a two-hand station No programming; reset mode and presets set on the relay Up to PL e / SIL 3; 22.5 mm wide; multi-reset of up to 10 relays from one reset button
Vital safety controller Many devices guarding the same hazard, such as every door on a cell No programming Up to 30 DYNlink devices in series at PL e
Pluto safety PLC Multiple zones, muting, zone-dependent stops, speed or analog monitoring, line-level safety Pluto Manager (free): ladder logic with TÜV-approved function blocks Up to 32 Pluto units on one safety bus; gateways to plant networks

When is a Sentry safety relay enough?

When the machine has a short list of independent safety functions and no logic between them. Sentry relays cover applications up to PL e / SIL 3, in two styles. Universal USR models handle most applications from one part number: 1- and 2-channel contact devices, OSSD devices, two-hand devices, and contact mats, bumpers, and edges, so one relay type covers most spares. Single-function SSR models are matched to one device type, such as the SSR20 for two-hand control stations. Timer variants and expansion relays (BSR and TSR series) add delayed or additional safe outputs. Browse the full range under safety relays.

When does Vital beat a stack of relays?

When several devices all need to stop the same motion. With conventional relays, reaching PL e usually means one relay per device because series-connected contacts lose fault detection. Vital uses DYNlink to put up to 30 devices on one controller at PL e, replacing what would otherwise be a panel of relays or a small safety PLC.

Which Pluto safety PLC should you specify?

Pluto uses an "all-master" concept: every Pluto on the safety bus makes decisions about its own safety zone while sharing data with the others, so zones can be added, split, or changed without restructuring a master/slave architecture. Common models:

  • Pluto S20 v2 (2TLA020070R4700): 20 I/O (8 failsafe inputs, 8 non-failsafe outputs/failsafe inputs, 2 individually failsafe relay outputs, 2 individually failsafe transistor outputs). Standalone, no Pluto safety bus.
  • Pluto B20 v2 (2TLA020070R4600): the same 20 I/O with the Pluto safety bus, for machines that will share safety data with other Pluto units.
  • Pluto S46 v2 (2TLA020070R1800): the same 46 I/O as the B46 v2, standalone without the safety bus.
  • Pluto B46 v2 (2TLA020070R1700): 46 I/O (24 failsafe inputs, 16 non-failsafe outputs/failsafe inputs, 4 individually failsafe relay outputs, 2 individually failsafe transistor outputs) with safety bus, for larger cells.
  • Pluto Gateway, PROFINET (2TLA020071R9300): two-way communication between the Pluto bus and the machine PLC. The gateway family also covers EtherNet/IP (GATE-EIP, 2TLA020071R9000), Modbus TCP, EtherCAT, PROFIBUS, DeviceNet, CANopen, and SERCOS III.

Pluto D20 and D45 models add failsafe analog inputs for applications such as speed or position monitoring. Pluto Manager programs the system in ladder logic using TÜV-approved function blocks, and is provided free of charge. A replacement Pluto can be hot-swapped and reloaded at the push of a button, which keeps a failed unit from turning into a long outage.

Which ABB Jokab devices go on the machine?

Guard and door monitoring: Eden

Eden is ABB Jokab's coded non-contact safety sensor. The Adam sensor mounts on the frame and the Eva actuator on the door. The Adam DYNlink sensor (2TLA020051R5300) connects straight into a Pluto or Vital DYNlink circuit, while OSSD versions of Adam work with any safety relay or safety PLC. The Eva general code actuator (2TLA020046R0800) is rated IP69K for washdown; choose a unique code Eva where defeat resistance per EN ISO 14119 is a requirement. More options are under safety sensors, switches and locks.

Point-of-operation and perimeter guarding: Orion

The Orion1-4-14-180-B (2TLA022300R1100) is a Type 4 safety light curtain with 14 mm finger resolution, 1800 mm protected height, and a 0.2 to 6 m range. 30 mm hand-resolution versions cover applications where hand detection is sufficient, and Orion1 Extended versions add muting, blanking, and cascading. See the full safety light curtains and light grids range.

Emergency stop: Smile

The Smile 11 emergency stop (2TLA030051R0000) packages the e-stop button in a compact enclosure with 2 NC contacts, a status LED in the button, and an M12-5 connector, which cuts panel cutouts and field wiring. Additional e-stop and pilot device options are under emergency stops and pilot devices.

Operator control: enabling devices and two-hand controls

The JSHD4 three-position enabling device is built for teaching, troubleshooting, and test running inside a guarded area; the JSHD4 bottom part with cable gland and 10 screw connections (2TLA020005R1700) is one of the modular bases. For two-hand control, the ergonomic JSTD1-A Safeball (2TLA020007R3000) pairs with a two-hand-rated Sentry relay or Pluto. Pressure-sensitive safety mats round out presence sensing at floor level.

ABB Jokab quick reference: part numbers at Automation Distribution

Function ABB Jokab product Part number
Safety PLC, standalone Pluto S20 v2 2TLA020070R4700
Safety PLC, safety bus Pluto B20 v2 2TLA020070R4600
Safety PLC, 46 I/O Pluto B46 v2 2TLA020070R1700
Network gateway Pluto Gateway, PROFINET 2TLA020071R9300
DYNlink adapter Tina 3A 2TLA020054R0200
Non-contact sensor Eden Adam, DYNlink 2TLA020051R5300
Actuator, IP69K Eden Eva, general code 2TLA020046R0800
Safety light curtain Orion1-4-14-180-B 2TLA022300R1100
Emergency stop Smile 11 2TLA030051R0000
Two-hand control JSTD1-A Safeball 2TLA020007R3000

ABB Jokab Safety FAQ

Can a single-channel safety circuit really reach PL e?

Yes, with a dynamic signal. A correctly wired DYNlink circuit reaches up to PL e, Category 4 per EN ISO 13849-1 with up to 10 devices on one Pluto input, because the pulsed signal provides the fault detection that a static single channel cannot.

Does Pluto Manager require a license?

No. Pluto Manager is provided free of charge and programs every Pluto model, from the Pluto S20 v2 to the Pluto B46 v2.

What is the difference between Pluto S and Pluto B models?

The safety bus. S models such as the Pluto S20 v2 run standalone. B models such as the Pluto B20 v2 connect to the Pluto safety bus, where up to 32 units share safety data without configuring the communication.

How does Pluto talk to the machine PLC?

Through a Pluto gateway for the plant network, such as EtherNet/IP, Modbus TCP, or the Pluto PROFINET gateway (2TLA020071R9300). Safety functions, diagnostics, and memory bits are passed to the standard PLC for HMI display and sequencing, while the safety decisions stay in Pluto.

Can I use ABB Jokab devices with another brand's safety controller?

Yes. OSSD versions of Eden sensors, Orion light curtains, and contact-based devices such as the Smile 11 emergency stop work with any suitably rated safety relay or safety PLC. DYNlink versions need a Pluto or Vital.

Automation Distribution is an authorized ABB distributor, including the ABB Jokab Safety line. Browse the full industrial safety selection, start a project with the Safety Project Initiation Form, or call 1-888-600-3080 to discuss your application.