Schneider Electric HDA36030 Molded Case Circuit Breaker 600V 30A
Schneider Electric
$1,124.00
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 30A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Product Certifications:
- UL || CSA || NOM
- Sustainable Offer Status:
- Green Premium product
- Mounting Height:
- 4.5 in
- Device Application:
- distribution
- Rohs Exemption Information:
- Yes
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Circuit Breaker Application:
- HACR rated
- Magnetic Tripping Current:
- 750-750 A
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Ambient Air Temperature For Storage:
- -50-85 °C
- Ambient Air Temperature For Operation:
- -2-70 °C
- Poles Description:
- 3P
- Net Weight:
- 2.2 kg
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Height:
- 163 mm
- Depth:
- 86 mm
- Quality Labels:
- CE
- Circularity Profile:
- ENVEOLI2206027EN
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Quantity Per Set:
- 1
- Pvc Free:
- Yes
- Pollution Degree:
- 3 IEC 60947-1
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Breaking Capacity Code:
- D
- Suitability For Isolation:
- yes IEC 60947-2
- Width:
- 104 mm
- Terminal Identifier:
- AL150HD
- Control Type:
- toggle
- Warranty:
- 18 months
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Mounting Support:
- bracket
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Eu Rohs Directive:
- Compliant with Exemptions
- Trip Unit Technology:
- thermal-magnetic
- Line Rated Current:
- 30-30 A
- Communication Interface:
- Modbus || Ethernet
- Product Or Component Type:
- circuit breaker
- Network Frequency:
- 50/60 Hz
- Utilisation Category:
- category A
- Mounting Mode:
- I-Line bracket)
- Mercury Free:
- Yes
- Wire Stripping Length:
- 16 mm
- Electrical Connection:
- I-Line connection, line || lugs, load
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Color:
- Black
- Range:
- PowerPact
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Environmental Disclosure:
- ENVPEP2206027EN
- Magnetic Hold Current:
- 350 A
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Phase Connection:
- ABC
- Protected Poles Description:
- 3t
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Product Name:
- PowerPact H
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Continuous Current Rating:
- 0.8
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View