ABB X500-B4-48-XD PSTX Enclosed 500HP Motor Protection System with Advanced Torque Control and Extreme Duty Features
ABBABB X500-B4-48-XD PSTX Enclosed Softstarter, 500HP, 480V, Type 4, Extreme Duty with Emergency Bypass
The ABB X500-B4-48-XD is a PSTX extreme duty enclosed softstarter in a Type 4 enclosure for 480 V motors, combining a PSTX softstarter with an ABB Tmax XT circuit breaker and an AC-3 emergency bypass.
Automation Distribution supplies the X500-B4-48-XD as an authorized ABB distributor. PSTX extreme duty enclosed softstarters are the ultimate softstarting solution. Includes all features of the PSTX normal duty, sized for heavy duty applications, plus an AC-3 emergency bypass. Both the PSTX softstarter and TMAX XT breakers are utilized. Door mounted pilot devices include PSTX keypad, hand-off-auto selector switch, start and stop pushbuttons, power on pilot light, run pilot light, fault pilot light, normal/emergency bypass selector switch, emergency bypass start and stop pushbuttons and emergency bypass pilot light. Good for Normal Duty class 10 starts for 600HP/720A, heavy duty class 30 starts for 500HP/590A, SCCR rating of 65kA, 480V and type 4 enclosure.
Key Features
- Normal duty (class 10 starts): 600 HP / 720 A
- Heavy duty (class 30 starts): 500 HP / 590 A
- Short-circuit current rating (SCCR): 65 kA
- 480 V, Type 4 enclosure
- PSTX softstarter with Tmax XT circuit breaker
- Door-mounted PSTX keypad, hand-off-auto selector, start/stop pushbuttons and power, run and fault pilot lights
- AC-3 emergency bypass with normal/bypass selector, bypass start/stop pushbuttons and bypass pilot light
Specifications
| Manufacturer | ABB |
| Part Number | X500-B4-48-XD |
| Series | PSTX Enclosed |
| Product Type | Enclosed softstarter |
| Duty | Extreme duty |
| Motor Rating, Normal Duty (Class 10) | 600 HP / 720 A |
| Motor Rating, Heavy Duty (Class 30) | 500 HP / 590 A |
| Voltage | 480 V |
| Enclosure | Type 4 |
| SCCR | 65 kA |
| Disconnect | ABB Tmax XT circuit breaker |
| Emergency Bypass | AC-3 bypass |
Part Number Breakdown: X500-B4-48-XD
| Code | Meaning |
|---|---|
| X500 | 500 HP (catalog size) |
| B4 | Type 4 enclosure |
| 48 | 480 V |
| XD | Extreme Duty with Emergency Bypass |
Authorized ABB Distributor. Automation Distribution supplies genuine ABB motor control products. Contact our team for technical support, cross-references or volume pricing on the X500-B4-48-XD.
- Series:
- PSTX Enclosed
- Duty:
- Extreme duty
- Motor Rating, Normal Duty (Class 10):
- 600 HP / 720 A
- Motor Rating, Heavy Duty (Class 30):
- 500 HP / 590 A
- Voltage:
- 480 V
- Enclosure:
- Type 4
- SCCR:
- 65 kA
- Disconnect:
- ABB Tmax XT circuit breaker
- Emergency Bypass:
- AC-3 bypass
- Spec Sheet:
- View