The Baumer UNAM 18P1703 10233682 is a high-performance ultrasonic sensor with a scanning range of 100 to 700 mm and a far limit scanning range of 110 to 700 mm. It features a typical hysteresis of 4% Sde and a repeat accuracy of 0.5 mm. This sensor is equipped with synchronization capabilities, a response and release time of less than 50 ms, and operates at a sonic frequency of 240 kHz. It includes a potentiometer for adjustments and a target indication flashing for alignment aid. The output is indicated by a green LED, and it supports a voltage supply range of 12 to 30 VDC with a maximum current consumption of 30 mA. The output circuit is a PNP make function (NO) with an output current of 200 mA. It also features short circuit and reverse polarity protection, and a voltage drop of less than 2 VDC. The sensor is housed in a cylindrical threaded, brass nickel-plated body, measuring 18 mm in diameter and 89 mm in length, and is connected via a 2-meter cable. It operates within a temperature range of -10 to +60 °C and is rated IP 67 for protection against dust and water ingress.
- Scanning range Sd:
- 100 700 mm
- Scanning range far limit Sde:
- 110 700 mm
- Hysteresis typ.:
- 4 % Sde
- Repeat accuracy:
- 0.5 mm
- Synchronization:
- Yes
- Temperature drift:
- < 0,18 % Sde/K
- Response time ton (sync on):
- < 50 ms
- Release time toff (sync on):
- < 50 ms
- Sonic frequency:
- 240 kHz
- Adjustment:
- Potentiometer
- Alignment aid:
- Target indication flashing
- Output indicator:
- LED green
- Voltage supply range +Vs:
- 12 30 VDC
- Current consumption max. (no load):
- 30 mA
- Output circuit:
- PNP make function (NO)
- Output current:
- 200 mA
- Voltage drop Vd:
- <2 VDC
- Residual ripple:
- < 10 % Vs
- Short circuit protection:
- Yes
- Reverse polarity protection:
- Yes
- Design:
- Cylindrical threaded
- Housing material:
- Brass nickel plated
- Width / diameter:
- 18 mm
- Height / length:
- 89 mm
- Connection types:
- Cable, L=2 m
- Operating temperature:
- -10 +60 °C
- Protection class:
- IP 67
- Datasheet:
- View;QN-QUOTE-REQUEST=true