PULS CPS20.121 DIN Rail Power Supply, 12V 30A 360W, 100-240VAC, Class I Div 2, Dimension C-Series
PULSThe PULS CPS20.121 is a 12V DC, 30A, 360W DIN rail power supply from the PULS DIMENSION C-Series. It accepts a 100-240V AC wide-range input with active power factor correction, reaches up to 92.6% efficiency, and fits a 65mm-wide footprint on a 35mm DIN rail. Output is adjustable from 12 to 15V DC (27A, 405W at 15V), and the unit delivers full rated power from -25°C to +60°C with no fan required.
A typical 120A peak current for 15ms (about four times nominal) trips downstream fuses and circuit breakers quickly on a faulted branch, protecting adjacent 12V circuits from voltage loss. Hazardous location approvals (Class I, Division 2 and ATEX/IECEx Zone 2), marine approvals, and a DC-OK relay contact make the CPS20.121 a strong fit for demanding 12V control and instrumentation panels.
Key Features
- 12V DC, 30A, 360W output, adjustable 12-15V DC via front potentiometer (factory set to 12.0V)
- 100-240V AC wide-range input with active PFC (power factor 0.99 at 120V AC)
- Up to 92.6% efficiency with excellent partial load efficiency (91.6% average at 230V AC)
- 120A peak for 15ms for fast fuse and breaker tripping on faulty output branches
- Safe HiccupPLUS overload mode with automatic restart once the overload clears
- Active inrush current limitation, 13A peak maximum
- Full power from -25°C to +60°C, operational to +70°C with derating
- DC-OK relay contact and green DC-OK LED for remote output monitoring
- Single Use / Parallel Use jumper for load sharing and redundant configurations
- Only 65mm wide to save panel space
- Class I Div 2, ATEX, IECEx, DNV and ABS approvals
- 3-year PULS warranty
Specifications
| Output | |
|---|---|
| Output Voltage | 12V DC nominal |
| Adjustment Range | 12-15V DC (factory setting 12.0V) |
| Output Current | 30A at 12V; 27A at 15V |
| Output Power | 360W at 12V; 405W at 15V |
| Peak Current | 120A typical for up to 15ms (once every 5 seconds) |
| Ripple and Noise | < 100mVpp (20Hz to 20MHz) |
| Overload Behavior | Continuous current above 6V DC; HiccupPLUS mode below 6V DC |
| Hold-up Time | 35ms typical at 30A; 80ms typical at 15A |
| Output Over-Voltage Protection | 17.3V DC typical, 18V DC maximum |
| Back-Feeding Load Resistance | Up to 16V DC |
| Input | |
| Input Voltage | 100-240V AC nominal (85-264V AC range) |
| Input Frequency | 50-60Hz ±6% |
| Input Current | 3.3A at 120V AC; 1.8A at 230V AC (typical) |
| Power Factor | 0.99 at 120V AC; 0.95 at 230V AC |
| Inrush Current | 9A / 7A peak typical at 120 / 230V AC (13A peak maximum) |
| Efficiency | 91.4% at 120V AC; 92.6% at 230V AC |
| Power Losses | 33.9W at 120V AC; 28.8W at 230V AC (full load) |
| Branch Circuit Rating | Approved for branch circuits up to 30A (UL) / 32A (IEC) without additional protection |
| DC Input | Not permitted |
| Environmental and Reliability | |
| Operating Temperature | -25°C to +70°C (derate 0.75A/°C from +60°C to +70°C; 22.5A at +70°C) |
| Storage Temperature | -40°C to +85°C |
| Humidity | 5 to 95% r.h., non-condensing |
| Altitude | Up to 2000m without restriction; up to 5000m with derating |
| Vibration / Shock | IEC 60068-2-6 / IEC 60068-2-27 |
| Corrosion Testing | ISA-71.04 G3 (Harsh) and IEC 60068-2-60 Method 4 |
| MTBF (SN 29500, IEC 61709) | 554,000h at 230V AC, 30A, +40°C |
| EMC | EN 61000-6-1/-2 immunity; Class B conducted and radiated emissions; SEMI F47 voltage sag immunity |
| Mechanical and Connections | |
| Dimensions (W x H x D) | 65 x 124 x 127mm (2.56 x 4.88 x 5.0 in), plus DIN rail depth |
| Weight | 2.2 lb (1000g) |
| Mounting | 35mm DIN rail (EN 60715), 7.5 or 15mm height; input terminals on the bottom |
| Input / Output Terminals | Screw terminals, AWG 20-10 (two pins per output pole) |
| DC-OK Terminals | Spring-clamp terminals, AWG 26-14 |
| DC-OK Relay Rating | 60V DC 0.3A, 30V DC 1A, 30V AC 0.5A (resistive) |
| Degree of Protection | IP20 |
| Cooling | Convection, no fan |
| Approvals and Safety | |
| Safety | UL 508 Listed; UL 60950-1 Recognized; IEC 60950-1 CB Scheme; IEC 61010-2-201 |
| Hazardous Locations | CSA Class I, Division 2, Groups A, B, C, D, T3; ATEX and IECEx Zone 2 (Ex ec nC IIC T3 Gc) |
| Marine | DNV Type Approved; ABS Design Assessment |
| Output Isolation | SELV (IEC/EN 60950-1); PELV (IEC/EN 60204-1) |
| Regulatory | CE, REACH, WEEE, CCC, KC |
Applications
The CPS20.121 powers 12V DC loads in industrial control, process control, and measurement equipment, including 12V solenoid valves, contactors, and pneumatic modules whose pick-up coils draw several times their steady-state current. Its peak current reserve and large internal output capacitance (5,600µF) keep 12V branches stable while a faulted branch breaker trips, which matters in panels where PLC ride-through is limited to roughly 10ms.
The unit is also approved for charging 12V lead-acid and maintenance-free batteries when the output is set precisely to the battery's end-of-charge voltage, with a 40A or 50A breaker or blocking diode between supply and battery. With Class I Div 2, ATEX/IECEx Zone 2, DNV, and ABS approvals, it suits oil and gas skids, marine and offshore panels, and hazardous-location instrumentation (Zone 2 installations require an IP54 enclosure meeting EN 60079-0).
Parallel and Redundant Operation
Move the front jumper to "Parallel Use" to share load between multiple CPS20.121 units for higher output power or N+1 redundancy. For true redundancy that isolates a failed unit, PULS recommends pairing the CPS20.121 with a YR80.242 dual-input redundancy module (preferred) or YR40.245 single-channel redundancy modules, and monitoring each supply through its DC-OK relay contact.
Compatible Accessories
- ZM2.WALL: Wall mounting bracket for flat-surface mounting without a DIN rail
- ZM13.SIDE: Side mounting bracket, with or without DIN rail
- YR80.242: Redundancy module, 2 x 40A inputs, 80A output
- YR40.245: Redundancy module, 40A single channel with plug connector output
Installation Notes
- Mount with input terminals on the bottom; other orientations require output current derating.
- Minimum clearances: 40mm top, 20mm bottom, 5mm left and right (15mm next to a heat source).
- Class of Protection I: a PE (protective earth) connection is required.
- If external input protection is used, choose a breaker of at least 10A, B- or C-characteristic, to avoid nuisance tripping.
Need help sizing a 12V power system?
Automation Distribution is an authorized PULS distributor. Our team can help you select redundancy modules, mounting brackets, and the right PULS supply for your panel.
Contact Automation Distribution- Series:
- Dimension C-Series
- Output Voltage:
- 12V DC
- Adjustment Range:
- 12-15V DC
- Output Current:
- 30A at 12V, 27A at 15V
- Output Power:
- 360W at 12V, 405W at 15V
- Peak Current:
- 120A for 15ms
- Input Voltage:
- 100-240V AC
- Input Frequency:
- 50-60Hz
- Power Factor:
- 0.99 at 120V AC, 0.95 at 230V AC
- Efficiency:
- Up to 92.6%
- Hold-up Time:
- 35ms at full load
- Operating Temperature:
- -25 to +70°C
- Full Power Temperature:
- -25 to +60°C
- Ripple and Noise:
- Less than 100mVpp
- Dimensions (WxHxD):
- 65 x 124 x 127mm
- Weight:
- 2.2 lb
- Mounting:
- 35mm DIN rail
- Terminals:
- Screw terminals
- Signal Output:
- DC-OK relay contact
- Parallel Operation:
- Yes
- Degree of Protection:
- IP20
- Approvals:
- UL 508, UL 60950-1, CSA Class I Div 2, ATEX, IECEx, DNV, ABS
- Warranty:
- 3 years