Datasensing AH1/CP-3FAN Ø6.5 mm Inductive Sensor, Shielded, Long Distance, PNP NC, M8 Connector, ATEX

Datasensing
SKU:
AH1/CP-3FAN
Availability:
Est. lead time: 20 work days
$83.87
Condition:
New
Current Stock:

Datasensing AH1/CP-3FAN Ø6.5 mm Inductive Sensor

The Datasensing AH1/CP-3FAN is a Ø6.5 mm inductive proximity sensor that detects metal targets without contact, with shielded (flush) mounting, PNP NC output and an M8 connector. Datasensing is the Datalogic group's sensor company, formed from Datalogic's sensor business and M.D. Micro Detectors.

AH1/CP-3FAN Specifications

Part numberAH1/CP-3FAN
SeriesAH
TechnologyInductive Sensor
HousingØ6.5 mm
MountingShielded (flush)
Distance classLong distance
OutputPNP NC
ConnectionM8 connector
ApprovalsATEX II 3G Ex nA IIC T5, II 3D Ex tD A22 IP67 T90°C
Datalogic descriptionInductive sensor Ø6,5 mm LD shielded NC/PNP conn. M8 II 3G Ex nA IIC T5, II 3D Ex tD A22 IP67 T90°C

Key Features

  • Non-contact detection of ferrous and non-ferrous metals with no moving parts to wear
  • Shielded models mount flush in metal; unshielded models need a clear zone but reach farther
  • Long-distance version extends the sensing range over standard models of the same size
  • Approvals: ATEX II 3G Ex nA IIC T5, II 3D Ex tD A22 IP67 T90°C

Applications

  • Part presence and end-of-travel detection on machine tools and fixtures
  • Cylinder, slide and gripper position feedback
  • Gear, cam and shaft speed or rotation monitoring
  • Metal part counting on conveyors

Frequently Asked Questions

What is the difference between shielded and unshielded inductive sensors?

A shielded (flush) sensor can be mounted with its face flush in metal. An unshielded (non-flush) sensor has a longer range but needs metal-free space around its face.

Do non-ferrous metals change the sensing distance?

Yes. Sensing distance is rated on mild steel; aluminium, brass and copper are detected at a shorter distance.

PNP or NPN, which do I need?

PNP (sourcing) outputs suit most US and European PLC inputs. NPN (sinking) outputs suit sinking inputs, common on Asian controllers.

Is the AH1/CP-3FAN a Datalogic or Datasensing part?

Both names apply. Datasensing is the Datalogic group's sensor company and also includes the former M.D. Micro Detectors range.

Questions about configuration or integration?

Automation Distribution carries the Datasensing AH1/CP-3FAN and the wider Datasensing sensor range from the Datalogic group. Ask us to help with sensing distance, output wiring or a cross-reference from another brand.

Contact Automation Distribution
Series:
AH
Technology:
Inductive Sensor
Housing:
Ø6.5 mm
Mounting:
Shielded (flush)
Output:
PNP NC
Connection:
M8 connector
Approvals:
ATEX II 3G Ex nA IIC T5, II 3D Ex tD A22 IP67 T90°C