Datasensing AM1/AP-3A86AN M12 Inductive Sensor, Shielded, Sn 4 mm, PNP NO, 5 m Cable, ATEX

Datasensing
SKU:
AM1/AP-3A86AN
Availability:
Est. lead time: 20 work days
$68.54
Condition:
New
Current Stock:

Datasensing AM1/AP-3A86AN M12 Inductive Sensor

The Datasensing AM1/AP-3A86AN is an M12 inductive proximity sensor that detects metal targets without contact, with shielded (flush) mounting, 4 mm nominal sensing distance, PNP NO output and 5 m cable. Datasensing is the Datalogic group's sensor company, formed from Datalogic's sensor business and M.D. Micro Detectors.

AM1/AP-3A86AN Specifications

Part numberAM1/AP-3A86AN
SeriesAM
TechnologyInductive Sensor
HousingM12
MountingShielded (flush)
Nominal sensing distance4 mm
OutputPNP NO
Connection5 m cable
ApprovalsATEX II 3G Ex nA IIC T5, II 3D Ex tD A22 IP67 T90°C
Datalogic descriptionInductive sensor M12 shielded NO/PNP cable 5m II 3G Ex nA IIC T5, II 3D Ex tD A22 IP67 T90°C

AM Series Data

Series specificationValue
Operating voltage10-30 Vdc, max ripple 10%
Output current200 mA max (3-100 mA on 2-wire models)
Operating temperature-25 to +70 °C
Protection degreeIP67
HousingNickel-plated brass, PBT sensing face
ProtectionsShort-circuit, reverse polarity, inductive load
IndicatorYellow LED, output state

Key Features

  • Non-contact detection of ferrous and non-ferrous metals with no moving parts to wear
  • Shielded models mount flush in metal; unshielded models need a clear zone but reach farther
  • Approvals: ATEX II 3G Ex nA IIC T5, II 3D Ex tD A22 IP67 T90°C

Applications

  • Part presence and end-of-travel detection on machine tools and fixtures
  • Cylinder, slide and gripper position feedback
  • Gear, cam and shaft speed or rotation monitoring
  • Metal part counting on conveyors

Frequently Asked Questions

What is the difference between shielded and unshielded inductive sensors?

A shielded (flush) sensor can be mounted with its face flush in metal. An unshielded (non-flush) sensor has a longer range but needs metal-free space around its face.

Do non-ferrous metals change the sensing distance?

Yes. Sensing distance is rated on mild steel; aluminium, brass and copper are detected at a shorter distance.

PNP or NPN, which do I need?

PNP (sourcing) outputs suit most US and European PLC inputs. NPN (sinking) outputs suit sinking inputs, common on Asian controllers.

Is the AM1/AP-3A86AN a Datalogic or Datasensing part?

Both names apply. Datasensing is the Datalogic group's sensor company and also includes the former M.D. Micro Detectors range.

Questions about configuration or integration?

Automation Distribution carries the Datasensing AM1/AP-3A86AN and the wider Datasensing sensor range from the Datalogic group. Ask us to help with sensing distance, output wiring or a cross-reference from another brand.

Contact Automation Distribution
Series:
AM
Technology:
Inductive Sensor
Housing:
M12
Mounting:
Shielded (flush)
Sensing Distance:
4 mm
Output:
PNP NO
Connection:
5 m cable
Approvals:
ATEX II 3G Ex nA IIC T5, II 3D Ex tD A22 IP67 T90°C
Operating voltage:
10-30 Vdc, max ripple 10%
Operating temperature:
-25 to +70 °C
Protection degree:
IP67