EC Titanium Integrated Motor-Drives

ABB Baldor-Reliance EC Titanium motors deliver IE5+ (NEMA Premium 5) ultra-premium efficiency from a Ferrite-Assisted Synchronous Reluctance (FASR) design. FASR pairs a synchronous reluctance rotor with non-rare-earth ferrite magnets, so you get IE5-class efficiency and near-unity power factor without depending on rare-earth magnet supply.

EC Titanium is a variable-speed, inverter-duty platform. It runs on a drive, not across the line. Order it as a motor-only unit to pair with your own VSD, or as an integrated motor-drive with the drive built onto the motor (top-mount or axial-mount), which removes the separate VFD, cuts panel space, and reduces field wiring.

What this category covers

Spec Range in this category
Efficiency class IE5+ ultra-premium (NEMA Premium 5, IE5 per IEC TS 60034-30-2)
Motor technology Ferrite-Assisted Synchronous Reluctance (FASR), non-rare-earth magnets
Duty Inverter duty only, per NEMA MG1 Part 31.4.4.2 (runs on a drive)
Configurations Motor-only, top-mount integrated drive, axial-mount integrated drive
Power range 1 to 20 HP (0.75 to 15 kW) motor-only; 1 to 10 HP top-mount; 1 to 7.5 HP axial-mount
Base speed 1800 RPM (60 Hz), 1500 RPM (50 Hz), with strong efficiency above base speed
Enclosure TEFC, IP54/IP55 depending on configuration
Frames NEMA 140, 180, 210 (184T, 213TC, 215T) and IEC 90, 112, 132 (D112, D132)
Construction Rolled steel, Class F insulation with Class B rise, internal shaft grounding brush
Brand ABB Baldor-Reliance

Three ways to buy: motor-only, top-mount, axial-mount

Every EC Titanium catalog number carries the EC stem. The position after it tells you the configuration, which is the first thing to settle because it decides whether a drive is included.

Code Configuration What you get
M Motor only (1 to 20 HP) FASR motor to pair with your own VSD. No drive included.
T Top-mount drive (1 to 10 HP) Integrated drive mounted on top of the motor. Plug-and-play, no separate VFD.
A Axial-mount drive (1 to 7.5 HP) Integrated drive on the opposite drive end for a tighter overall envelope.

In the rating field, H designates a horsepower rating and K designates a kilowatt rating (for example 5P5 reads as 5.5 kW). Frame and mounting suffixes follow. Confirm voltage, frame, and drive I/O against the specific catalog number before ordering.

Where EC Titanium earns its place

Efficiency that holds at part load

Fans, pumps, and compressors rarely run at full speed. EC Titanium keeps efficiency high across the speed range and above base speed, where ABB rates it at up to 16% efficiency gains at partial load versus alternative designs. That is where the operating-cost savings actually come from.

No rare-earth magnets

FASR uses ferrite magnets, not rare-earth. You get IE5+ efficiency without exposure to rare-earth pricing and supply volatility, which matters for OEMs standardizing on a platform for the long run.

 

Drive on the motor, off the panel

The integrated top-mount and axial-mount versions put the drive on the motor. That frees control-panel space, cuts motor-cable runs, and removes a separately mounted VFD from the design. Near-unity power factor also allows a smaller drive.

Built-in connectivity and quiet running

Integrated models carry a Modbus RJ45 serial interface plus digital, configurable, and relay I/O, and are ABB Ability ready for equipment monitoring. Low starting current and reduced cogging keep mechanical stress and noise down.

Typical applications

Variable-torque and variable-speed loads are the sweet spot: fans, blowers, pumps, compressors, and vacuum pumps across HVACR, water and wastewater, food processing, data centers, conveying, and general industrial systems. Roughly three quarters of industrial motor load drives pumps, fans, and compressors, which is exactly where EC Titanium's part-load efficiency pays back.

Selecting the right EC Titanium unit

Drive plan Have a VSD already? Choose motor-only. Want a self-contained unit? Choose top-mount or axial-mount.
Power and speed Size to the load. Note the power ceilings differ: motor-only to 20 HP, top-mount to 10 HP, axial-mount to 7.5 HP.
Frame standard NEMA (184T, 213TC, 215T) or IEC (D112, D132) to match the mount and driven equipment.
Envelope Top-mount adds height above the motor; axial-mount extends the non-drive end. Check clearance in the installed location.
I/O and comms For integrated units, confirm the drive I/O and Modbus interface match your control scheme.

EC Titanium motors: common questions

What efficiency class is EC Titanium?

IE5+ ultra-premium, equivalent to NEMA Premium 5 (IE5 per IEC TS 60034-30-2). That is a tier above IE4 Super Premium, and it holds efficiency well at partial load.

Can I run EC Titanium direct-on-line without a drive?

No. EC Titanium is inverter duty only, per NEMA MG1 Part 31.4.4.2. The integrated top-mount and axial-mount versions include the drive on the motor. The motor-only version must be paired with a variable speed drive.

What does FASR mean, and why ferrite instead of rare-earth?

FASR is Ferrite-Assisted Synchronous Reluctance. The design reaches IE5+ efficiency using ferrite magnets rather than rare-earth, which removes exposure to rare-earth supply and price swings while keeping near-unity power factor.

What is the difference between top-mount and axial-mount?

Both are integrated motor-drives. Top-mount places the drive above the motor; axial-mount places it on the opposite drive end for a tighter footprint. Top-mount is offered to 10 HP, axial-mount to 7.5 HP.

Can I pair the motor-only version with a non-ABB drive?

The motor-only version is built for open drive pairing and is compatible with most variable speed drives, including ABB's ACS380 and ACH580. Confirm the drive supports the motor's control profile for best efficiency at part load.

What loads is EC Titanium best suited for?

Variable-speed pumps, fans, blowers, compressors, and vacuum pumps in HVACR, water and wastewater, food processing, data centers, and general industrial systems, where equipment spends most of its time at partial load.

Not sure whether you need motor-only or an integrated drive?

Tell Automation Distribution the load, the speed range, and whether you already have a VSD, and we will spec the right EC Titanium configuration, confirm frame and drive I/O, and quote availability. Call 1-888-600-3080 or request a quote on the product page.