Lutze

Lutze A1392005 superflex n (c) pvc awg21/5c

(No reviews yet) Write a Review
SKU:
A1392005
Condition:
New
$1.84

Description

Technical Data

Construction

Description
SUPERFLEX?? N (C) PVC
Number of conductors/cross-section
(5G0.5)
Jacket material
Special PVC
Jacket color
grey RAL 7001
Outer ??
8,5 mm
Outer ??
0,333 inch
Weight
10,2 kg/100 m
Weight
71 Lbs/Mft
Cu-Index
4,4 kg/100 m
Cu-Index
29 Lbs/Mft

Element 1

Element construction
AWG20/5C
Conductor
CU-wire bare
Conductor category
  • IEC 60228, Class 6
  • Superfinely stranded DIN VDE 0295
  • class 6
Conductor marking
  • black
  • with black number print
  • green/yellow
Conductor marking standard
DIN EN 50334
Conductor insulation
Special TPE

overall construction

Overall stranding
  • conductors twisted without mechanical stress
  • layer pitch optimised
Overall wrapping
Fleece taping
Inner jacket
PVC
Overall shield
  • Braid shield
  • Tinned copper wires
Jacket characteristics
  • abrasion resistant
  • tough
  • Weather resistant
  • hydrolysis-resistant
  • microbe resistant
  • rot-resistant
  • UV resistant (normal lighting conditions)
  • Oil resistant
  • Flame-retardant
  • Silicone-free

Technical data

Rated voltage UN
600 V UL AWM
Test voltage type
AC3000V
Temperature according to UL
80 ???C
Temperature range moving
-5 ???C ?? +80 ???C
Temperature range fixed
-40 ???C ?? +80 ???C
Minimum bending radius moving
10??D
Minimum bending radius fixed
6??D

Element 1

Element construction
AWG20/5C
Insulation resistance at 20 ???C
100 M???km

Approvals/Standards

Approvals
  • cURus
  • AWM I/II A/B 80???C 600V FT1
UL style
  • AWM 2570
  • AWM 10429
Conformity
  • CE
  • RoHS
  • REACH
Burning behavior according to
  • UL VW-1
  • UL FT1
  • IEC 60332-1
  • DIN EN 60332-1-2
  • VDE 0482 322-1-2
Oil resistant according to
  • UL 4d100C
  • UL Oil Res 80 ???C
  • IEC 60811-404
UV-resistant according to
DIN EN ISO 4892-2-A

General

Note
CE These products are in conformity with the EU Low Voltage Directive 2014/35/EU

Machine and device construction, transport and conveyor technology, HVAC technology In dry and damp rooms As a monitoring, measurement and control cable for industrial applications For installation in energy chains with constant linear movement Anywhere where electrical interference fields can influence the signal transmission

View AllClose