Lutze A2171004 lutze driveflex n(c) servo 1

(No reviews yet) Write a Review
SKU:
A2171004
Condition:
New
QN-QUOTE-REQUEST:
true
  • Lutze A2171004 lutze driveflex n(c) servo 1
  • Lutze A2171004 lutze driveflex n(c) servo 1
$12.79

Description

Technical Data

Construction

Description
DRIVEFLEX?? XLPE (C) 1 TSP PVC
Number of conductors/cross-section
(4AWG10+1?????2?????AWG14)
Jacket material
PVC
Jacket color
black RAL 9005
Outer ?????
20,6 mm
Outer ?????
0,81 inch
Weight
62,5 kg/100 m
Weight
420 Lbs/Mft
Cu-Index
218 Lbs/Mft

Element 1

Element construction
AWG10/4C
Conductor construction
AWG 10 (105/30)
Conductor
  • AWG conductor
  • CU-wire tin-plated
Conductor category
fine wire
Conductor marking
  • black
  • with white number print
  • green/yellow
Conductor insulation
  • XLPE
  • RHW-2
Stranding
strands braided together

Element 2

Element construction
AWG14/1TSP
Conductor construction
AWG 14 (41/30)
Conductor
  • AWG conductor
  • CU-wire tin-plated
Conductor category
fine wire
Conductor marking
  • black
  • with white number print
Conductor insulation
  • XLPE
  • XHHW-2
Stranding
conductors stranded in pairs

overall construction

Drain wire
CU-wire tin-plated
Overall shield
  • Foil shield
  • Tinned copper wires
  • Braid shield
  • optical cover approx. 80%
Jacket characteristics
  • Oil resistant
  • Silicone-free

Technical data

Rated voltage UN
  • 600 V TC-ER
  • 1000 V Flexible VFD servo cable 90C
  • 1000 V WTTC
Temperature range fixed
-40 ???C ?? +90 ???C
Minimum bending radius fixed
6?????D

Element 1

Element construction
AWG10/4C

Element 2

Element construction
AWG14/1TSP

Approvals/Standards

Approvals
  • cULus
  • TC-ER
  • UL DP-1
  • WTTC
  • Class 1 Div. 2 per NEC
  • Art. 336, 392, 501
  • cUL TC
  • CIC FT4
  • UL 1277
  • Wet/Dry
  • P-07-KA130021-MSHA
Conformity
  • CE
  • RoHS
  • REACH
Oil resistant according to
Oil Res II

General

Note
CE These products are in conformity with the EU Low Voltage Directive 2014/35/EU

Shielded multi-conductor cable for VFD and Motor applications to connect power from drives to motors Cable design for harsh industrial environments and operating conditions with high noise levels XLPE thick wall insulation with low capacitance, ideal for applications with high voltage spikes and long cable runs Compliant with NFPA 79 for wiring of industrial machinery TC-ER for use with cable trays without conduit, which can reduce material and labor costs WTTC ?? wind turbine tray cable rating for use in wind power generation Dry, damp or wet conditions

View AllClose