Lutze A2200203 driveflex 3 symmetrical ground by the Foot
LutzeTechnical Data
Construction
Element 1
- AWG conductor
- CU-wire tin-plated
- black
- with white number print
- XLPE
- XHHW-2
Element 2
- AWG conductor
- CU-wire tin-plated
- XLPE
- 3C XHHW-2 (Ground/PEs)
overall construction
- Foil shield
- Aluminium laminate
- Braid shield
- Tinned copper wires
- optical cover approx. 80%
- Oil resistant
- Silicone-free
Technical data
- 600 V TC-ER
- 1000 V Flexible VFD servo cable 90C
- 1000 V WTTC
Element 1
Element 2
Approvals/Standards
- cULus
- WTTC
- TC-ER
- cUL TC
- CIC FT4
- Class 1 Div. 2 per NEC
- Art. 336, 392, 501
- UL 1277
- UL 2277
- Wet/Dry
- P-07-KA130021-MSHA
- CE
- RoHS
- REACH
General
Shielded VFD and Motor cable to connect power from drives to motors Three insulated symmetrical grounds design helps to reduce stray currents Cable design for harsh industrial environments and operating conditions with high noise levels 1 kV rated XLPE insulation with low capacitance, ideal for applications with high voltage spikes and long cable runs Compliant with NFPA 79 for wiring of industrial machinery TC-ER for use with cable trays without conduit, which can reduce material and labor costs WTTC ?? wind turbine tray cable rating for use in wind power generation Dry, damp or wet conditions