Schneider Electric

Schneider Electric 50438 Closed Toroid Pa50 Dia. 50Mm

(No reviews yet) Write a Review
SKU:
50438
UPC:
3303430504382
Condition:
New
Mounting Mode:
fixed plain backplate) || fixed profiled sheet metal) || fixed slotted backplate) || clip-on DIN rail) || clip-on Vigirex relay)
Width:
88 mm
Cable Outer Diameter:
25-25 mm 50-50 mm²
Standards:
IEC 60947-2
Product Or Component Type:
earth leakage current sensor
Range:
VigiPacT
[Ie] Rated Operational Current:
85 A
Ambient Air Temperature For Storage:
-55-85 °C
Ambient Air Temperature For Operation:
-35-70 °C
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Residual Short-Circuit Withstand Current:
85 kA / 0.5 s IEC 60947-2
Diameter:
inner 50 mm
Net Weight:
0.2 kg
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Depth:
29 mm
Calorific Value:
1.42 MJ
Environmental Characteristic:
exposure to damp heat not in service 25...55 °C, RH 95 %) 28 cycles IEC 60068-2-30 || salt mistKb/2 IEC 60068-2-52 || exposure to damp heat in servicecategory C2 48 hours IEC 60068-2-56
Warranty:
18 months
Range Compatibility:
VigiPacT RH10M residual current protection relay || VigiPacT RH10P residual current protection relay || VigiPacT RH21M residual current protection relay || VigiPacT RH21P residual current protection relay || VigiPacT RH68M residual current protection
[Uimp] Rated Impulse Withstand Voltage:
12 kV
Environmental Disclosure:
ENVPEP2310022EN
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ip Degree Of Protection:
connectors IP20 || IP30
Pollution Degree:
level 3 IEC 60664-1
[Ui] Rated Insulation Voltage:
1000 V
Rohs Exemption Information:
Yes
Height:
108 mm
Network Frequency:
45...440 Hz
Device Short Name:
PA50
Overvoltage Category:
IV
Mercury Free:
Yes
Transformer Ratio:
1/1000
Connections - Terminals:
screw connection 0.22-0.22 mm²
Eu Rohs Directive:
Compliant with Exemptions
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Device Application:
equipment monitoring and control
Product Certifications:
CE
Sustainable Offer Status:
Green Premium product
[Icw] Rated Short-Time Withstand Current:
85 kA 0.5 s
Circularity Profile:
ENVEOLI2310022EN
Network Type:
AC/DC
Current Transformer Type:
A type closed toroid
Catalog:
View
Datasheet:
View
$488.00

Description

closed toroid A type, for VigiPacT and Vigilhom, PA50, inner diameter 50mm, rated current 85A
View AllClose