Schneider Electric 56235 Earthleakage Relay Rh10P 300 Ma 240 V

(No reviews yet) Write a Review
SKU:
56235
UPC:
3303430562351
Condition:
New
Mechanical Robustness:
fire resistance IEC 60695-2-1 || IK protection 2 joulesIK07 EN 50102 || vibrations 13.2...100 Hz0.7 g || vibrations 2...13.2 Hz+/- 1 mm
Relative Humidity:
95-95 % 55-55 °C
Pollution Degree:
3 IEC 60664-1
Device Short Name:
RH10P
Earth-Leakage Protection Class:
type A
Type Of Measurement:
earth fault current internal measurement 80...100 %
Ip Degree Of Protection:
on front face IP40 EN/IEC 60529 || on side parts IP30 EN/IEC 60529 || on connection terminals IP20 EN/IEC 60529
Reset:
manual reset
Earth Leakage Current:
0.3-0.3 A
Eu Rohs Directive:
Compliant with Exemptions
Relay Application:
protection relay
Tamperproof Of Settings:
protected by sealable cover
California Proposition 65:
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Standards:
EN/IEC 60947-2 Annex M || EN/IEC 60755 || UL 1053 || CAN/CSA C22.2 No. 144
Warranty:
18 months
Residual Earth-Leakage Sensitity Adjustment Type:
fixed
[Ithe] Conventional Enclosed Thermal Current:
0.333333333333333
Ambient Air Temperature For Operation:
-35-70 °C
Electrical Shock Protection Class:
class II
Wire Stripping Length:
auxiliary power supply: 7 mm || fault: 7 mm || relay test and fault reset: 7 mm || sensor: 7 mm || voltage presence: 7 mm
Type Of Setting:
none
Rohs Exemption Information:
Yes
Electromagnetic Compatibility:
conducted and radiated emissionsB CISPR 11 || conducted radio-frequency immunity test3 IEC 61000-4-6 || electrostatic discharge immunity test4 IEC 61000-4-2 || high-energy conducted susceptibility4 IEC 61000-4-5 || low-energy conducted susceptibility
Overvoltage Category:
IV
Connections - Terminals:
auxiliary power supply terminal block 0.2-2.5 mm² flexible AWG 24...AWG 12 || auxiliary power supply terminal block 0.2-2.5 mm² rigid AWG 24...AWG 12 || auxiliary power supply terminal block 0.25-2.5 mm² flexible AWG 24...AWG 12 || fault terminal blo
Circularity Profile:
ENVEOLI2310023EN
Net Weight:
0.3 kg
Residual Earth-Leakage Time Delay Adjustment Type:
instantaneous
Ambient Air Temperature For Storage:
-55-85 °C
Tightening Torque:
auxiliary power supply: 0.6-0.6 N.m || fault: 0.6-0.6 N.m || relay test and fault reset: 0.6-0.6 N.m || sensor: 0.6-0.6 N.m || voltage presence: 0.6-0.6 N.m
[Us] Rated Supply Voltage:
220...240 V AC 50/60 Hz 55...110 %
Power Consumption In Va:
4 VA
Test Function:
local || remote test
Range:
VigiPacT
Mounting Support:
front panel
Earthing System:
IT || TN-S || TT
Network Rated Voltage:
1000-1000 V - AC 50/60 Hz maximum) || 1000-1000 V - AC 400 Hz maximum)
Cut-Out Dimensions:
68 x 68 mm
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Environmental Disclosure:
ENVPEP2310023EN
Depth:
78 mm
Width:
72 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Minimum Load:
10 mA 12 V
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Ik Degree Of Protection:
IK07 EN 50102
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Height:
72 mm
Sustainable Offer Status:
Green Premium product
Monitoring:
electronics continuous) || power supply continuous) || relay/sensor link continuous)
Range Compatibility:
VigiPacT TOA earth leakage current sensor || VigiPacT A earth leakage current sensor || VigiPacT L earth leakage current sensor
Product Or Component Type:
residual current protection relay
Mercury Free:
Yes
$1,607.00

Description

Residual current protection relay, VigiPacT RH10P, 300mA, 220/240VAC 50/60Hz, front panel mounting
View AllClose