Schneider Electric 9050JCK22V14 Timer Relay 240Vac 10Amp +Options

(No reviews yet) Write a Review
SKU:
9050JCK22V14
UPC:
785901032748
Condition:
New
Height:
61 mm
Reach Free Of Svhc:
Yes
Rohs Exemption Information:
Yes
Depth:
104 mm
Mercury Free:
Yes
Mounting Support:
socket
Width:
43 mm
Sustainable Offer Status:
Green Premium product
Shape Of Pin:
tubular
Time Delay Type:
off-delay
Warranty:
18 months
China Rohs Regulation:
X
Product Compatibility:
8501NR61 || 8501NR62
Product Certifications:
UL Listed || CE || UL Recognized
Ambient Air Temperature For Operation:
-18-150 °F
Contacts Type And Composition:
2 NO + 2 NC
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Toxic Heavy Metal Free:
Yes
Circularity Profile:
ENVEOLI1406037EN
Range Of Product:
9050JCK
Hold-In Power Consumption In Va:
2-2 VA
Switch Function:
DPDT
Product Or Component Type:
timer
[Uc] Control Circuit Voltage:
24 V AC/DC
Line Rated Current:
0.416666666666667
Contacts Material:
silver nickel
Environmental Disclosure:
ENVPEP1406037EN
Time Delay Range:
0.3...30 s
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Pin Number:
11
Maximum Switching Voltage:
240 V AC
  • Schneider Electric 9050JCK22V14 Timer Relay 240Vac 10Amp +Options
  • Schneider Electric 9050JCK22V14 Timer Relay 240Vac 10Amp +Options
  • Schneider Electric 9050JCK22V14 Timer Relay 240Vac 10Amp +Options
$98.00

Description

9050JCK plug in timers are designed to provide low cost timing in a plug in housing. This timer has an off delay timing mode. Input voltage to the timer must be applied continuously. When the customer supplied trigger switch closes, the timer relay contacts change state instantaneously. When the trigger switch opens, the time delay begins. When the delay is complete, the timer relay contacts return to their shelf state. If the trigger switch closes before the time delay is complete, then timing is reset. When the trigger switch opens, the delay begins again, and the timer relay contacts remain in their energized state. The timing range of 0.3 to 30 seconds is easily adjustable with a knob on the top of the timer. This plug in timer plugs into an 8501NR61 or 8501NR62 relay socket. These relay sockets can be mounted on 35 mm DIN 3 mounting track or directly to a panel. All wiring is made to the relay socket. The DPDT contacts are rated 10 amperes resistive at 120 VAC, 240 VAC and 30 VDC, 3 amperes inductive at 120 VAC, 240 VAC and 30 VDC, 1/3 HP on the NC contacts at 120 VAC and 240 VAC, 1/2 HP on the NO contacts at 120 VAC and 240 VAC. This plug in timer is powered up with 24 VAC/VDC. 9050JCK plug in timers are UL listed when the proper 8501NR relay socket is used, UL component recognized and CSA certified.