Contacts Material:
silver nickel
Depth:
104 mm
Hold-In Power Consumption In Va:
2-2 VA
[Uc] Control Circuit Voltage:
120 V AC || 110 V DC
Mercury Free:
Yes
Rohs Exemption Information:
Yes
Toxic Heavy Metal Free:
Yes
Environmental Disclosure:
ENVPEP1406037EN
Width:
43 mm
Circularity Profile:
ENVEOLI1406037EN
Line Rated Current:
0.416666666666667
Sustainable Offer Status:
Green Premium product
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Range Of Product:
9050JCK
Time Delay Range:
0.6...60 min
Reach Free Of Svhc:
Yes
Mounting Support:
socket
Ambient Air Temperature For Operation:
-18-150 °F
Product Certifications:
UL Recognized || CE || UL Listed
Time Delay Type:
off-delay
Switch Function:
DPDT
Pin Number:
11
Contacts Type And Composition:
2 NO + 2 NC
Product Compatibility:
8501NR62 || 8501NR61
China Rohs Regulation:
X
Maximum Switching Voltage:
240 V AC
Height:
61 mm
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Shape Of Pin:
tubular
Product Or Component Type:
timer
Catalog:
View
Datasheet:
View
  • Schneider Electric 9050JCK28V20 Timer Relay 240Vac 10A T-Jck
  • Schneider Electric 9050JCK28V20 Timer Relay 240Vac 10A T-Jck
  • Schneider Electric 9050JCK28V20 Timer Relay 240Vac 10A T-Jck
$107.00

Description

9050JCK plug in timers are designed to provide low cost timing in a plug in housing. This timer has an off delay timing mode. Input voltage to the timer must be applied continuously. When the customer supplied trigger switch closes, the timer relay contacts change state instantaneously. When the trigger switch opens, the time delay begins. When the delay is complete, the timer relay contacts return to their shelf state. If the trigger switch closes before the time delay is complete, then timing is reset. When the trigger switch opens, the delay begins again, and the timer relay contacts remain in their energized state. The timing range of 1.2 to 120 minutes is easily adjustable with a knob on the top of the timer. This plug in timer plugs into an 8501NR61 or 8501NR62 relay socket. These relay sockets can be mounted on 35 mm DIN 3 mounting track or directly to a panel. All wiring is made to the relay socket. The DPDT contacts are rated 10 amperes resistive at 120 VAC, 240 VAC and 30 VDC, 3 amperes inductive at 120 VAC, 240 VAC and 30 VDC, 1/3 HP on the NC contacts at 120 VAC and 240 VAC, 1/2 HP on the NO contacts at 120 VAC and 240 VAC. This plug in timer is powered up with 12 VAC/VDC. 9050JCK plug in timers are UL listed when the proper 8501NR relay socket is used, UL component recognized and CSA certified.
View AllClose