Schneider Electric 9050JCK29V20 Timer Relay 240Vac 10A T-Jck

(No reviews yet) Write a Review
SKU:
9050JCK29V20
UPC:
785901056614
Condition:
New
Time Delay Range:
1.2...120 min
Contacts Type And Composition:
2 NO + 2 NC
Hold-In Power Consumption In Va:
2-2 VA
Sustainable Offer Status:
Green Premium product
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Maximum Switching Voltage:
240 V AC
Environmental Disclosure:
ENVPEP1406037EN
Warranty:
18 months
Circularity Profile:
ENVEOLI1406037EN
Ambient Air Temperature For Operation:
-18-150 °F
Product Compatibility:
8501NR62 || 8501NR61
Switch Function:
DPDT
Shape Of Pin:
tubular
Product Or Component Type:
timer
Mounting Support:
socket
Toxic Heavy Metal Free:
Yes
Height:
61 mm
Rohs Exemption Information:
Yes
Mercury Free:
Yes
Width:
43 mm
Product Certifications:
UL Recognized || CE || UL Listed
Reach Free Of Svhc:
Yes
Contacts Material:
silver nickel
[Uc] Control Circuit Voltage:
120 V AC || 110 V DC
Pin Number:
11
Line Rated Current:
0.416666666666667
China Rohs Regulation:
X
Range Of Product:
9050JCK
Time Delay Type:
off-delay
Depth:
104 mm
Reach Regulation:
Free of Substances of Very High Concern above the threshold
  • Schneider Electric 9050JCK29V20 Timer Relay 240Vac 10A T-Jck
  • Schneider Electric 9050JCK29V20 Timer Relay 240Vac 10A T-Jck
  • Schneider Electric 9050JCK29V20 Timer Relay 240Vac 10A T-Jck
$107.00

Description

9050JCK plug in timers are designed to provide low cost timing in a plug in housing. This timer has an off delay timing mode. Input voltage to the timer must be applied continuously. When the customer supplied trigger switch closes, the timer relay contacts change state instantaneously. When the trigger switch opens, the time delay begins. When the delay is complete, the timer relay contacts return to their shelf state. If the trigger switch closes before the time delay is complete, then timing is reset. When the trigger switch opens, the delay begins again, and the timer relay contacts remain in their energized state. The timing range is fixed at 1200 seconds. This timer does not have a knob on the top of the timer. This plug in timer plugs into an 8501NR61 or 8501NR62 relay socket. These relay sockets can be mounted on 35 mm DIN 3 mounting track or directly to a panel. All wiring is made to the relay socket. The DPDT contacts are rated 10 amperes resistive at 120 VAC, 240 VAC and 30 VDC, 3 amperes inductive at 120 VAC, 240 VAC and 30 VDC, 1/3 HP on the NC contacts at 120 VAC and 240 VAC, 1/2 HP on the NO contacts at 120 VAC and 240 VAC. This plug in timer is powered up with 120 VAC / 110 VDC. 9050JCK plug in timers are UL listed when the proper 8501NR relay socket is used, UL component recognized and CSA certified.
View AllClose