Schneider Electric ATS01N222LU Soft-Start Stop 22A 220 240V
Schneider Electric
$283.82
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
This Altistart 01 soft starter is DIN rail mounted and can feed 3-phase asynchronous motors with a rating up to 22A. This Altistart 01 can be used for a motor rated power up to 5.5kW or 7.5hp for 3-phase (200V to 240V AC). This DIN rail mounted soft starter is designed to enable smooth start for simple machines such as conveyors, conveyor belts, pumps, fans, compressors, automatic doors and gates, small cranes and belt-driven machinery. It is 45mm wide, this makes it one of the smallest soft starters on the market; it can be installed nearly everywhere. It features an Integrated bypass, this reduces noise and decreases heat dissipation. Simple setup with only 2 settings: possible to configure by non-specialists. It provides smooth starting for your machinery, avoiding mechanical stresses and extending their service life.
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Network Frequency:
- 47.5...63 Hz
- Range Of Product:
- Altistart 01
- Mercury Free:
- Yes
- Net Weight:
- 0.56 kg
- Depth:
- 131 mm
- Starting Time:
- 1 s / 100 || 5 s / 20 || 10 s / 10 || adjustable from 1 to 10 s
- Discrete Input Type:
- logic LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm
- Discrete Input Logic:
- positive LI1, LI2, BOOST < 5 V <= 0.2 mA > 13 V, >= 0.5 mA
- Electrical Connection:
- 4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuit || screw connector - rigid without cable end 1 0.5...2.5 mm² AWG 14 control circuit || 4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuit || screw connector - rigid
- Warranty:
- 18 months
- Product Certifications:
- GOST || CSA || C-tick || UL || B44.1-96/ASME A17.5 for starter wired to the motor delta terminal || CCC
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Maximum Horse Power Rating:
- 5 hp, 3 phase 200...240 V || 7.5 hp, 3 phase 200...240 V
- Product Or Component Type:
- soft starter
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Icl Starter Rating:
- 22 A
- Compatibility Code:
- ATS01N2
- China Rohs Regulation:
- X
- Type Of Start:
- start with voltage ramp
- Vibration Resistance:
- 1 gn 13-150 Hz)EN/IEC 60068-2-6 || 1.5 mm peak to peak 3-13 Hz)EN/IEC 60068-2-6
- Relative Humidity:
- 5-95 % without condensation or dripping water EN/IEC 60068-2-3
- Ambient Air Temperature For Operation:
- -10-40 °C without derating) || 40-50 °C with current derating of 2 % per °C)
- Motor Starter Type:
- soft starter
- Marking:
- CE
- Reach Free Of Svhc:
- Yes
- Current Consumption:
- 110 A at nominal load
- Supply Voltage Limits:
- 180-264 V
- Rohs Exemption Information:
- Yes
- Discrete Output Current:
- 2 A DC-13 || 3 A AC-15
- Phase:
- 3 phase
- Height:
- 154 mm
- [Uc] Control Circuit Voltage:
- built into the starter
- Starting Torque:
- 30...80 % of starting torque of motor connected directly on the line supply
- Product Specific Application:
- simple machine
- Supply Frequency:
- 50...60 Hz - 5...5 %
- Discrete Input Voltage:
- 24...40 V
- Width:
- 45 mm
- Ip Degree Of Protection:
- IP20
- Discrete Output Type:
- open collector logic LO1 end of starting signal || relay outputs R1A, R1C NO
- Function Available:
- integrated bypass
- Power Dissipation In W:
- 124.5 W in transient state || 4.5 W at full load and at end of starting
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Ambient Air Temperature For Storage:
- -25-70 °C EN/IEC 60947-4-2
- [Us] Rated Supply Voltage:
- 200...240 V - 10...10 %
- Motor Power Kw:
- 4 kW, 3 phase 200...240 V || 5.5 kW, 3 phase 200...240 V
- Maximum Switching Current:
- relay outputs 2 A 250 V AC cos phi = 0.5 20 ms inductive || relay outputs 2 A 30 V DC cos phi = 0.5 20 ms inductive
- Minimum Switching Current:
- 10 mA 6 V DC relay outputs
- Shock Resistance:
- 15 gn 11 ms EN/IEC 60068-2-27
- Electromagnetic Compatibility:
- conducted and radiated emissions level B CISPR 11 || conducted and radiated emissions level B IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-2 || EMC immunity level 3 EN 50082-1 || EMC
- Assembly Style:
- with heat sink
- Operating Position:
- vertical +/- 10 degree
- Tightening Torque:
- 0.5-0.5 N.m || 1.9-2.5 N.m
- Output Voltage:
- <= power supply voltage
- Utilisation Category:
- AC-53B EN/IEC 60947-4-2
- Pollution Degree:
- 2 EN/IEC 60947-4-2
- Operating Altitude:
- <= 3280.84 ft (1000 m) without derating || > 3280.84 ft (1000 m) with current derating of 2.2 % per additional 100 m
- Standards:
- EN/IEC 60947-4-2
- Device Short Name:
- ATS01
- Display Type:
- 1 LED Green)starter powered up || 1 LED Yellow)nominal voltage reached
- Deceleration Time Symb:
- adjustable from 1 to 10 s
- Power Range:
- 4-6 kW 200-240 V 3 phase
- Product Destination:
- asynchronous motors
- Discrete Output Voltage:
- 24 V 6...30 V) open collector logic
- Toxic Heavy Metal Free:
- Yes
- Catalog:
- View
- Datasheet:
- View