This Altistart 22 soft starter can feed 3-phase asynchronous motors in supply line connection. It has a rating of 62A, a rated power from 15kW to 37kW and a rated voltage from 230V to 500V AC. It is designed for simple and complex machines such as centrifugal and piston pumps, fans, screw compressors and material handling equipment. Slim form factor improves versatility, allows mounting in frames of any kind of machines. It features an Integrated bypass, this reduces noise and decreases heat dissipation. Compatibility with SoMove software allows configurations and settings to be easily transferred, meaning spares can be quickly installed. It provides smooth starting for your machinery, avoiding mechanical stresses and extending their service life.
- Physical Interface:
- RS485 multidrop
- Output Current:
- 0.4...1 Icl adjustable
- Product Or Component Type:
- soft starter
- Discrete Input Voltage:
- 24 V <= 30 V
- Product Specific Application:
- pumps and fans
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Electromagnetic Compatibility:
- conducted and radiated emissions level A IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-2 || immunity to electrical transients level 4 IEC 61000-4-4 || immunity to radiated radio-electr
- Product Certifications:
- CCC || UL || CSA || GOST || C-tick
- Minimum Switching Current:
- 100 mA 12 V DC relay outputs)
- Power Dissipation In W:
- 59 W for standard applications
- Utilisation Category:
- AC-53A
- China Rohs Regulation:
- X
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Discrete Input Type:
- LI1, LI2, LI3) logic, 5 mA 4.3 kOhm
- [Uc] Control Circuit Voltage:
- 230 V - 15...10 % 50/60 Hz
- Shock Resistance:
- 15 gn 11 ms IEC 60068-2-27
- Net Weight:
- 12 kg
- Communication Port Protocol:
- Modbus
- Network Frequency:
- 45...66 Hz
- Operating Position:
- vertical +/- 10 degree
- Phase:
- 3 phase
- Operating Altitude:
- <= 3280.84 ft (1000 m) without derating || > 3280.84...< 6561.68 ft (> 1000...< 2000 m) with current derating of 2.2 % per additional 100 m
- Motor Starter Type:
- soft starter
- Type Of Cooling:
- forced convection
- Installed Device:
- 31
- [Us] Rated Supply Voltage:
- 230...600 V - 15...10 %
- Icl Starter Rating:
- 62 A connection in the motor supply line for standard applications
- Range Of Product:
- Altistart 22
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Device Connection:
- in the motor supply line
- Discrete Output Number:
- 2
- Connector Type:
- 1 RJ45
- Type Of Start:
- start with torque control (current limited to 3.5 In)
- Width:
- 145 mm
- Product Destination:
- asynchronous motors
- Protection Type:
- phase failure line || thermal protection motor || thermal protection starter
- Discrete Input Logic:
- positive logic LI1, LI2, LI3 < 5 V <= 2 mA > 11 V, >= 5 mA
- Ambient Air Temperature For Storage:
- -25-70 °C
- Component Name:
- ATS22
- Warranty:
- 18 months
- Noise Level:
- 45 dB
- Mercury Free:
- Yes
- Transmission Rate:
- 4800, 9600 or 19200 bps
- Communication Data Link:
- serial
- Discrete Input Number:
- 3
- Supply Frequency:
- 50...60 Hz - 10...10 %
- Pollution Degree:
- level 2 IEC 60664-1
- Ptc Probe Input:
- 750 Ohm
- Supply Voltage Limits:
- 195-660 V
- Height:
- 295 mm
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Ambient Air Temperature For Operation:
- -10-40 °C without derating) || 40-60 °C with current derating 2.2 % per °C)
- Marking:
- CE
- Rohs Exemption Information:
- Yes
- Power Range:
- 30-50 kW 480-500 V 3 phase || 15-25 kW 200-240 V 3 phase || 30-50 kW 380-440 V 3 phase
- Control Circuit Consumption:
- 20 W
- Vibration Resistance:
- 1 gn 13-200 Hz)IEC 60068-2-6 || 1.5 mm 2-13 Hz)IEC 60068-2-6
- Standards:
- IEC 60947-4-2
- Ip Degree Of Protection:
- IP20
- Depth:
- 207 mm
- Discrete Output Type:
- relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O || relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
- Maximum Switching Current:
- 5 A 250 V AC resistive 1 relay outputs || 5 A 30 V DC resistive 1 relay outputs || 2 A 250 V AC inductive 0.4 20 ms relay outputs || 2 A 30 V DC inductive 7 ms relay outputs
- Function Available:
- internal bypass
- Motor Power Kw:
- 15 kW 230 V || 30 kW 400 V || 30 kW 440 V || 37 kW 500 V
- Relative Humidity:
- 0-95 % without condensation or dripping water IEC 60068-2-3
- Assembly Style:
- with heat sink
- Factory Setting Current:
- 52 A
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View