Schneider Electric

Schneider Electric ATS22D88Q Electronic Soft Starter Control 220V Pow

(No reviews yet) Write a Review
SKU:
ATS22D88Q
UPC:
3606480167232
Condition:
New
Phase:
3 phase
Output Current:
0.4...1 Icl adjustable
Ambient Air Temperature For Operation:
-10-40 °C without derating) || 40-60 °C with current derating 2.2 % per °C)
China Rohs Regulation:
X
Transmission Rate:
4800, 9600 or 19200 bps
Ip Degree Of Protection:
IP20
Power Dissipation In W:
66 W for standard applications
Physical Interface:
RS485 multidrop
Control Circuit Consumption:
20 W
Minimum Switching Current:
100 mA 12 V DC relay outputs)
Function Available:
internal bypass
Discrete Input Voltage:
24 V <= 30 V
Standards:
IEC 60947-4-2
Protection Type:
phase failure line || thermal protection motor || thermal protection starter
Communication Port Protocol:
Modbus
Relative Humidity:
0-95 % without condensation or dripping water IEC 60068-2-3
Maximum Switching Current:
5 A 250 V AC resistive 1 relay outputs || 5 A 30 V DC resistive 1 relay outputs || 2 A 250 V AC inductive 0.4 20 ms relay outputs || 2 A 30 V DC inductive 7 ms relay outputs
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || > 3280.84...< 6561.68 ft (> 1000...< 2000 m) with current derating of 2.2 % per additional 100 m
Motor Power Kw:
22 kW 230 V || 45 kW 400 V || 45 kW 440 V
Ptc Probe Input:
750 Ohm
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Discrete Input Logic:
positive logic LI1, LI2, LI3 < 5 V <= 2 mA > 11 V, >= 5 mA
Electromagnetic Compatibility:
conducted and radiated emissions level A IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-2 || immunity to electrical transients level 4 IEC 61000-4-4 || immunity to radiated radio-electr
Power Range:
15-25 kW 200-240 V 3 phase || 30-50 kW 380-440 V 3 phase
Warranty:
18 months
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Discrete Output Type:
relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O || relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
Type Of Start:
start with torque control (current limited to 3.5 In)
Rohs Exemption Information:
Yes
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Product Destination:
asynchronous motors
Discrete Input Number:
3
Height:
295 mm
Product Certifications:
CCC || CSA || UL || GOST || C-tick
Discrete Output Number:
2
Product Specific Application:
pumps and fans
Component Name:
ATS22
Device Connection:
to the motor delta terminals || in the motor supply line
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Depth:
207 mm
Marking:
CE
Supply Frequency:
50...60 Hz - 10...10 %
Installed Device:
31
Network Frequency:
45...66 Hz
Supply Voltage Limits:
195-484 V
[Us] Rated Supply Voltage:
230...440 V - 15...10 %
Vibration Resistance:
1 gn 13-200 Hz)IEC 60068-2-6 || 1.5 mm 2-13 Hz)IEC 60068-2-6
Icl Starter Rating:
88 A connection in the motor supply line for standard applications
Width:
145 mm
Motor Starter Type:
soft starter
Discrete Input Type:
LI1, LI2, LI3) logic, 5 mA 4.3 kOhm
Type Of Cooling:
forced convection
Range Of Product:
Altistart 22
Utilisation Category:
AC-53A
Operating Position:
vertical +/- 10 degree
Pollution Degree:
level 2 IEC 60664-1
Mercury Free:
Yes
Noise Level:
45 dB
Assembly Style:
with heat sink
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Product Or Component Type:
soft starter
Net Weight:
12 kg
Connector Type:
1 RJ45
Factory Setting Current:
81 A
[Uc] Control Circuit Voltage:
230 V - 15...10 % 50/60 Hz
Ambient Air Temperature For Storage:
-25-70 °C
Brochure:
View
Catalog:
View
Datasheet:
View
$1,900.50

Description

This soft starter can feed 3-phase asynchronous motors in supply line or delta connection. It has a rating of 88A and 230V to 440V, a rated power up to 45kW (400V to 440V in supply line) and up to 75kW (400V to 440V in motor delta connection). It is designed for simple and complex machines such as centrifugal and piston pumps, fans, screw compressors and material handling equipment. Slim form factor improves versatility; allows mounting in frames of any kind of machines. It features an Integrated bypass, this reduces noise and decreases heat dissipation. Compatibility with SoMove software allows configurations and settings to be easily transferred, meaning spares can be quickly installed. It provides smooth starting for your machinery, avoiding mechanical stresses and extending their service life.
View AllClose