Schneider Electric

Schneider Electric ATS480M10Y Soft Starter Ats480 1000A 208 To 690V

(No reviews yet) Write a Review
SKU:
ATS480M10Y
UPC:
3.60648E+12
Condition:
New
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Device Short Name:
ATS480
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Maximum Deflection Under Vibratory Load (During Transport):
1.75 mm at 2...9 Hz
Maximum Acceleration Under Vibratory Load (During Transport):
15 m/s² at 200...500 Hz || 10 m/s² at 9...200 Hz
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Analogue Input Number:
1
[Uimp] Rated Impulse Withstand Voltage:
6 kV
Maximum Acceleration Under Shock Load (During Transport):
100 m/s² at 11 ms
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Range Of Product:
Altivar Soft Starter ATS480
Relay Output Number:
3
[In] Rated Current Pwr Loss Specifctn:
1000.0 A
Display Screen Available:
TRUE
Sustainable Offer Status:
Green Premium product
Width:
770.0 mm
Depth:
329.0 mm
Standards:
IEC 60947-4-2 || UL 60947-4-2 || IEC 60664-1
Height:
890.0 mm
Apparent Power:
0.2 kVA
Analogue Output Number:
1
Product Or Component Type:
soft starter
Function Available:
external bypass control || pre-heating || smoke extraction || multi-motor cascade || second motor set || user management || ports and services hardening || security event logging || cybersecure firmware update || single direction
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S2 according to IEC 60721-3-3
Pollution Degree:
level 3
Power Loss Per Device Current Dependent:
2845.0 W
Phase:
3 phase
Motor Power Kw:
250.0 kW 230 V in the motor supply line normal duty || 220.0 kW 230 V in the motor supply line heavy duty || 500.0 kW 400 V in the motor supply line normal duty || 400.0 kW 400 V in the motor supply line heavy duty || 630.0 kW 440 V in the motor supp
Discrete Output Number:
2
Number Of Addresses:
0-227 Modbus serial
Net Weight:
115.0 kg
China Rohs Regulation:
X
Physical Interface:
2-wire RS 485
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
[Ie] Rated Operational Current:
normal duty 1000.0 A 40 °C)
Maximum Permanent Current:
790.0 A at 40 °C heavy duty
Maximum Deflection Under Vibratory Load (During Storage):
1.75 mm at 2...9 Hz
Maximum Acceleration Under Vibratory Load (During Storage):
15 m/s² at 200...500 Hz || 10 m/s² at 9...200 Hz
Accuracy Class:
class 10E
Supply Frequency:
50...60 Hz - 20...20 %
Discrete Output Type:
DQ1) programmable digital output <= 30 V || DQ2) programmable digital output <= 30 V
Output Current Drift:
150-700 %
Discrete Input Number:
4
Relay Output Type:
relay outputs R1A 1 NO || relay outputs R1B 1 NO || relay outputs RIC NO/NC programmable
Transmission Frame:
RTU
[Us] Rated Supply Voltage:
208...690 V - 15...10 %
Operating Position:
vertical +/- 10 degree
Maximum Acceleration Under Shock Load (During Storage):
100 m/s² at 11 ms
Ambient Air Temperature For Storage:
-25-70 °C
Power Loss Static Current Independent:
25.0 W
[Uc] Control Circuit Voltage:
110...250 V AC 50/60 Hz - 15...10 %
Utilisation Category:
AC-3A || AC-53A
Maximum Switching Current:
relay outputs 2 A 250 V AC || relay outputs 2 A 30 V DC || relay outputs
Analogue Output Type:
current output AQ1 0...20 mA or 0...10 V 500 Ohm
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Relative Humidity:
0-95 % without condensation or dripping water IEC 60068-2-3
Type Of Polarization:
no impedance Modbus serial
Protection Type:
phase failure line || integrated thermal protection motor || thermal protection starter || current overload motor || underload motor || excessive starting time, locked rotor motor || motor phase loss motor || line supply phase loss line || line suppl
Minimum Switching Current:
100 mA 12 V DC relay outputs
Data Format:
8 bits, configurable odd, even or no parity
Maximum Horse Power Rating:
350.0 hp 208 V normal duty || 250.0 hp 208 V heavy duty || 350.0 hp 230 V normal duty || 300.0 hp 230 V heavy duty || 800.0 hp 460 V normal duty || 600.0 hp 460 V heavy duty || 1000.0 hp 575 V normal duty || 800.0 hp 575 V heavy duty
Ambient Air Temperature For Operation:
40-60 °C with current derating of 2 % per °C) || -15-40 °C without derating)
Electromagnetic Compatibility:
conducted and radiated emissions level A IEC 60947-4-2 || conducted and radiated emissions with bypass level B IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-11 || immunity to electrica
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Option Card:
communication module Profibus DP V1 || communication module PROFINET || communication module Modbus TCP/EtherNet/IP || communication module CANopen daisy chain || communication module CANopen Sub-D || communication module CANopen open style
Connector Type:
1 RJ45
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || > 3280.84...13123.36 ft (> 1000...4000 m) with current derating 1 % per 100 m
Circularity Profile:
ENVEOLI2102014EN
Discrete Input Type:
STOP) logic inputs, 3500 Ohm || RUN) logic inputs, 3500 Ohm || DI3) programmable as logic input, 3500 Ohm || DI4) programmable as logic input, 3500 Ohm
Marking:
CE || CCC || UKCA || EAC || RCM || cULus
Torque Control:
TRUE
Transmission Rate:
1200...256000 bit/s
Communication Port Protocol:
Modbus serial
Mercury Free:
Yes
Method Of Access:
slave Modbus serial
Ip Degree Of Protection:
IP00
Discrete Input Logic:
programmable digital input < 5 V
Product Specific Application:
process and infrastructures
Environmental Disclosure:
ENVPEP2102014EN
Product Certifications:
CE || cULus || CCC || UKCA || RCM || EAC || DNV || ABS || BV || CCS
Device Connection:
in the motor supply line || to the motor delta terminals
[Ui] Rated Insulation Voltage:
690 V
Integrated Motor Overload Protection:
TRUE
Upgradeability:
Upgraded components available
Rohs Exemption Information:
Yes
Product Destination:
asynchronous motors
Datasheet:
View
$13,749.99

Description

Altivar Soft Starter ATS480 is intended to start and stop asynchronous motors supplied from 208V to 690V. It meets the requirements of the most demanding applications in normal and heavy duty. With an operational rated current of 1000A in normal duty, it supplies motor from 250kW to 900kW according to mains voltage. Designed for digitization, connected, optimized to meet cybersecurity standard, it simplifies project execution and maximizes the availability of applications. Its torque control (TCS) masters acceleration and deceleration. It efficiently stops high inertia application thanks to the dynamic braking and DC injection. It could be connected in-line or inside the delta to reduce its operational current. The embedded test routine simplifies the commissioning inside the delta. Its dimensions are 770mm (width) x 329mm (depth) x 890mm (height) and it weighs 115kg. Altivar Soft Starter ATS480 is designed to address process, infrastructures and industrial machines. It conforms to IEC/EN60947-4-1. It is certified CE, cULus, UKCA, CCC, RCM, EAC, and Marine certified DNV, ABS, BV and CCS. Display terminals, remote mounting kit, communication modules are common with Altivar Drives. Line chokes, DNV kits are common with ATS48. ATS480 is compatible with ATS48, it has same footprint, fixing, torque control algorithm, I/O, menus… The integration of Altivar Soft Starter ATS480 in EcoStruxure drastically simplifies architecture selection, detailed design and execution in automation and electrical systems. It is a Green Premium product designed to take the environmental considerations beyond current directives and regulations, compliant with RoHS and REACH.
View AllClose