Altivar Machine ATV12 is an offer of variable speed drives for commercial equipment and simple machines. It works at a rated power up to 0.18kW / 0.25hp and a rated voltage from 200V to 240V AC. It is designed with heatsink for normal environments and fan-cooled enclosure. It has advanced PID and catch on the fly functions, basic cabling, and easy motor control setting. Based on the needs, it can be delivered without heatsink, with embedded EMC filter, or as standard version. The Altivar 12 drive integrates as standard the Modbus communication protocol. This Altivar Machine ATV12 is designed for simple applications, in industry, commercial machines and HVAC machines such as conveyors, pumps, extractors, access barriers and treadmills. It conforms to IEC, UL and other international standards. SoMove software compatibility enables saving and transfering of configurations to spare drive, reducing maintenance downtime. It features an optimized application of power and torque for ventilation and pumping applications, this allows up to 30% energy savings.
- Marking:
- CE
- Emc Filter:
- integrated
- Range Of Product:
- Altivar 12
- Ip Degree Of Protection:
- IP20
- Asynchronous Motor Control Profile:
- voltage/frequency ratio (V/f) || sensorless flux vector control || quadratic voltage/frequency ratio
- Power Dissipation In W:
- natural 18.0 W
- Depth:
- 102.2 mm
- Transient Overtorque:
- 150-170 % of nominal motor torque depending on drive rating and type of motor
- Brake Chopper Integrated:
- FALSE
- Overvoltage Category:
- class III
- Frequency Resolution:
- analog input converter A/D, 10 bits || display unit 0.1 Hz
- Physical Interface:
- 2-wire RS 485
- With Safety Function Safe Speed Monitor (Ssm):
- FALSE
- Net Weight:
- 0.7 kg
- With Safety Function Safe Stop 1 (Ss1):
- FALSE
- Time Constant:
- 20 ms +/- 1 ms for reference change
- Ambient Air Temperature For Storage:
- -25-70 °C
- Maximum Output Voltage:
- 240 V
- Rohs Exemption Information:
- Yes
- Pollution Degree:
- 2
- Motor Power Kw:
- 0.18 kW
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Electromagnetic Compatibility:
- electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || electrostatic discharge immunity test level 3 IEC 61000-4-2 || immunity to conducted disturbances level 3 IEC 61000-4-6 || radiated radio-frequency electromagnetic field immunity
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Environmental Class (During Operation):
- class 3C3 according to IEC 60721-3-3 || class 3S2 according to IEC 60721-3-3
- Type Of Polarization:
- no impedance
- Sampling Duration:
- 20 ms +/- 1 ms logic input || 10 ms analogue input
- Standards:
- UL 508C || UL 618000-5-1 || IEC 61800-5-1 || IEC 61800-3
- Product Or Component Type:
- variable speed drive
- Protection Type:
- line supply overvoltage || line supply undervoltage || overcurrent between output phases and earth || overheating protection || short-circuit between motor phases || against input phase loss in three-phase || thermal motor protection via the drive by
- Connector Type:
- 1 RJ45
- Acceleration And Deceleration Ramps:
- U || linear from 0 to 999.9 s || S
- With Safety Function Safe Operating Stop (Sos):
- FALSE
- Product Certifications:
- NOM || CSA || C-tick || UL || GOST || RCM || KC
- Speed Drive Output Frequency:
- 0.5-400 Hz
- Maximum Output Frequency:
- 4 kHz
- Noise Level:
- 0 dB
- With Safety Function Safely Limited Position (Slp):
- FALSE
- Data Format:
- 8 bits, configurable odd, even or no parity
- Transmission Frame:
- RTU
- Apparent Power:
- 0.7 kVA 240 V heavy duty)
- Analogue Input Number:
- 1
- Discrete Input Number:
- 4
- Ambient Air Temperature For Operation:
- -10-40 °C without derating || 40-60 °C with current derating 2.2 % per °C
- [Us] Rated Supply Voltage:
- 200...240 V - 15...10 %
- Braking To Standstill:
- by DC injection
- With Safety Function Safe Direction (Sdi):
- FALSE
- Speed Range:
- 45311
- Maximum Horse Power Rating:
- 0.25 hp
- Nominal Switching Frequency:
- 4 kHz
- Base Load Current At High Overload:
- 1.4 A
- Width:
- 72 mm
- Motor Slip Compensation:
- preset in factory || adjustable
- Network Frequency:
- 50-60 Hz
- Transmission Rate:
- 9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s
- Communication Port Protocol:
- Modbus
- 4 Quadrant Operation Possible:
- FALSE
- Prospective Line Isc:
- 1 kA
- Mounting Mode:
- cabinet mount
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Insulation:
- electrical between power and control
- Vibration Resistance:
- 1 gn 13-200 Hz)IEC 60068-2-6 || 1.5 mm peak to peak 3-13 Hz) - drive unmounted on symmetrical DIN rail - IEC 60068-2-6
- Tightening Torque:
- 0.8 N.m
- Analogue Output Number:
- 1
- With Safety Function Safely Limited Speed (Sls):
- FALSE
- Height:
- 143 mm
- Quantity Per Set:
- set of 1
- With Safety Function Safe Brake Management (Sbc/Sbt):
- FALSE
- Electromagnetic Emission:
- radiated emissions environment 1 category C2 IEC 61800-3 2...16 kHz shielded motor cable || conducted emissions with integrated EMC filter environment 1 category C1 IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m || conducted emissions w
- With Sft Fct Safe Stop 2 (Ss2):
- FALSE
- Continuous Output Current:
- 1.4 A 4 kHz
- Operating Position:
- vertical +/- 10 degree
- Discrete Output Number:
- 2
- Linearity Error:
- +/- 0.3 % of maximum value analogue input
- Ambient Air Transport Temperature:
- -25-70 °C
- Maximum Acceleration Under Shock Impact (During Operation):
- 150 m/s² at 11 ms
- Communication Service:
- read holding registers (03) 29 words || write single register (06) 29 words || write multiple registers (16) 27 words || read/write multiple registers (23) 4/4 words || read device identification (43)
- Regulation Loop:
- adjustable PID regulator
- Relative Symmetric Network Frequency Tolerance:
- 0.05
- Operating Altitude:
- > 3280.84...6561.68 ft (> 1000...2000 m) with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
- With Safety Function Safe Position (Sp):
- FALSE
- Switching Frequency:
- 2...16 kHz adjustable || 4...16 kHz with derating factor
- Line Current:
- 3.4 A 100 V heavy duty) || 2.8 A 120 V heavy duty)
- With Safety Function Safe Torque Off (Sto):
- FALSE
- Relay Output Number:
- 1
- Relative Humidity:
- 5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
- Product Specific Application:
- simple machine
- China Rohs Regulation:
- X
- With Safety Function Safe Programmable Logic:
- FALSE
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Method Of Access:
- server Modbus serial
- Number Of Addresses:
- 1-247
- Mercury Free:
- Yes
- Shock Resistance:
- 15 gn 11 ms IEC 60068-2-27
- Maximum Transient Current:
- 2.1 A 60 s heavy duty) || 2.3 A 2 s heavy duty)
- Assembly Style:
- on base plate
- Maximum Acceleration Under Vibrational Stress (During Operation):
- 10 m/s² at 13...200 Hz
- Warranty:
- 18 months
- Supply Frequency:
- 50/60 Hz +/- 5 %
- Maximum Deflection Under Vibratory Load (During Operation):
- 1.5 mm at 2...13 Hz
- Nominal Output Current:
- 1.4 A
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View