Schneider Electric ATV212HD11N4 Atv212 11Kw 15Hp 480V Tri Cem Ip20
Schneider Electric
$1,648.74
This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 11kW / 15hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 6.45kg and its dimensions are, 180mm wide, 232mm high, 170mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.
- Electromagnetic Compatibility:
- electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
- Relative Humidity:
- 5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
- Product Certifications:
- C-tick || NOM 117 || CSA || UL
- Discrete Output Type:
- configurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Regulation Loop:
- adjustable PI regulator
- Width:
- 180 mm
- Physical Interface:
- 2-wire RS 485
- Transient Overtorque:
- 120-120 % of nominal motor torque +/- 10 % 60 s
- Sampling Duration:
- 2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
- Power Dissipation In W:
- 430 W
- Discrete And Process Manufacturing:
- building - HVAC compressor for scroll || building - HVAC fan || building - HVAC pump
- Tightening Torque:
- 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) || 2.5 N.m, 22 lb.in L1/R, L2/S, L3/T)
- Mercury Free:
- Yes
- Analogue Output Number:
- 1
- Ambient Air Temperature For Storage:
- -25-70 °C
- Protection Type:
- overheating protection drive || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit
- Continuous Output Current:
- 22.5 A 380 V || 22.5 A 460 V
- Dielectric Strength:
- 3535 V DC between earth and power terminals || 5092 V DC between control and power terminals
- Maximum Transient Current:
- 24.8 A 60 s
- Number Of Addresses:
- 1-247
- Local Signalling:
- for DC bus energized 1 LED (red)
- Maximum Switching Current:
- 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
- Product Or Component Type:
- variable speed drive
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Speed Range:
- 45301
- Discrete Output Number:
- 2
- Electrical Connection:
- VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 16-16 mm² / AWG 6
- Type Of Polarization:
- no impedance
- Pollution Degree:
- 2 IEC 61800-5-1
- Operating Altitude:
- 3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
- Net Weight:
- 6.45 kg
- Analogue Input Type:
- VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
- Warranty:
- 18 months
- Output Voltage:
- <= power supply voltage
- Rohs Exemption Information:
- Yes
- Braking To Standstill:
- by DC injection
- Ambient Air Temperature For Operation:
- -10-40 °C without derating) || 40-50 °C with derating factor)
- Accuracy:
- +/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C
- Connector Type:
- 1 open style || 1 RJ45
- Supply Frequency:
- 50...60 Hz - 5...5 %
- Torque Accuracy:
- +/- 15 %
- Response Time:
- FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
- Supply Voltage Limits:
- 323-528 V
- Power Range:
- 7-11 kW 380-440 V 3 phase || 7-11 kW 480-500 V 3 phase
- Acceleration And Deceleration Ramps:
- automatic based on the load || linear adjustable separately from 0.01 to 3200 s
- Type Of Cable:
- without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
- China Rohs Regulation:
- X
- Emc Filter:
- Class C2 EMC filter integrated
- Operating Position:
- vertical +/- 10 degree
- Transmission Rate:
- 9600 bps or 19200 bps
- Data Format:
- 8 bits, 1 stop, odd even or no configurable parity
- Speed Accuracy:
- +/- 10 % of nominal slip 0.2 Tn to Tn
- Frequency Resolution:
- display unit 0.1 Hz || analog input 0.024/50 Hz
- Switching Frequency:
- 6...16 kHz adjustable || 12...16 kHz with derating factor
- Product Specific Application:
- pumps and fans in HVAC
- Supply:
- internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
- Network Frequency:
- 47.5...63 Hz
- Vibration Resistance:
- 1.5 mm 3-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)EN/IEC 60068-2-8
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Air Flow:
- 147 m3/h
- Speed Drive Output Frequency:
- 0.5-200 Hz
- Prospective Line Isc:
- 22 kA
- Height:
- 232 mm
- Shock Resistance:
- 15 gn 11 ms IEC 60068-2-27
- Phase:
- 3 phase
- Asynchronous Motor Control Profile:
- voltage/frequency ratio, 2 points || voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || flux vector control without sensor, standard || voltage/frequency ratio - Energy Saving, quadratic U/f || voltage/frequency ratio, 5 point
- Option Card:
- communication card LonWorks
- Motor Slip Compensation:
- not available in voltage/frequency ratio motor control || adjustable || automatic whatever the load
- Noise Level:
- 51 dB 86/188/EEC
- Linearity Error:
- VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
- Transmission Frame:
- RTU
- Apparent Power:
- 17.1 kVA 380 V
- Standards:
- IEC 61800-3 category C2 || IEC 61800-3 environments 1 category C2 || IEC 61800-3 category C3 || IEC 61800-3 environments 1 category C3 || IEC 61800-3 environments 2 category C3 || UL Type 1 || IEC 61800-3 environments 1 category C1 || IEC 61800-3 env
- Range Of Product:
- Altivar 212
- Analogue Input Number:
- 2
- Communication Port Protocol:
- METASYS N2 || APOGEE FLN || LonWorks || BACnet || Modbus
- Functionality:
- mid
- Assembly Style:
- with heat sink
- Environmental Characteristic:
- classes 3C1 IEC 60721-3-3 || classes 3S2 IEC 60721-3-3
- Isolation:
- electrical between power and control
- Communication Service:
- read holding registers (03) 2 words maximum || time out setting from 0.1 to 100 s || write single register (06) || monitoring inhibitable || write multiple registers (16) 2 words maximum || read device identification (43)
- Specific Application:
- HVAC
- Discrete Input Logic:
- positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
- Minimum Switching Current:
- 3 mA 24 V DC configurable relay logic
- Motor Starter Type:
- variable speed drive
- Insulation Resistance:
- >= 1 mOhm 500 V DC for 1 minute
- Analogue Output Type:
- FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits
- Discrete Input Type:
- F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
- Product Destination:
- asynchronous motors
- Line Current:
- 16.8 A 480 V || 21.1 A 380 V
- Motor Power Kw:
- 11 kW
- Maximum Horse Power Rating:
- 15 hp
- Depth:
- 170 mm
- Device Short Name:
- ATV212
- [Us] Rated Supply Voltage:
- 380...480 V - 15...10 %
- Ip Degree Of Protection:
- IP20 on upper part without blanking plate on cover IEC 61800-5-1 || IP20 on upper part without blanking plate on cover IEC 60529 || IP21 IEC 61800-5-1 || IP21 IEC 60529 || IP41 on upper part IEC 61800-5-1 || IP41 on upper part IEC 60529
- Marking:
- CE
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Nominal Switching Frequency:
- 12 kHz
- Ip Degree Of Protection:
- IP21
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View