Schneider Electric ATV212HD22N4S Atv212 Slim Version 22Kw 30Hp 480V Tri C
Schneider Electric
$3,179.43
This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 22kW / 30hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 11.65kg and its dimensions are, 245mm wide, 330mm high, 190mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet. It is eco-friendly and complies with directives such as RoHS, WEEE, etc.relating to environmental protection.
- Product Or Component Type:
- variable speed drive
- Supply Frequency:
- 50...60 Hz - 5...5 %
- Relative Humidity:
- 5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
- Discrete Output Number:
- 2
- China Rohs Regulation:
- X
- Circularity Profile:
- ENVEOLI111242EN
- Network Frequency:
- 47.5...63 Hz
- Noise Level:
- 59.9 dB 86/188/EEC
- Asynchronous Motor Control Profile:
- voltage/frequency ratio, 2 points || voltage/frequency ratio, 5 points || voltage/frequency ratio - Energy Saving, quadratic U/f || voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || flux vector control without sensor, standar
- Speed Accuracy:
- +/- 10 % of nominal slip 0.2 Tn to Tn
- Linearity Error:
- VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
- Torque Accuracy:
- +/- 15 %
- Motor Starter Type:
- variable speed drive
- Device Short Name:
- ATV212
- Type Of Cable:
- without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
- Range Of Product:
- Altivar 212
- Isolation:
- electrical between power and control
- Analogue Output Type:
- FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits
- Vibration Resistance:
- 1.5 mm 3-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)EN/IEC 60068-2-8
- Motor Power Kw:
- 22 kW
- Transmission Rate:
- 9600 bps or 19200 bps
- Standards:
- EN 55011 class A group 1 || IEC 61800-3 environments 2 category C2 || IEC 61800-3 environments 2 category C1 || EN 61800-3 category C3 || IEC 61800-3 environments 1 category C2 || IEC 61800-3 category C2 || IEC 61800-3 category C3 || IEC 61800-5-1 ||
- Maximum Horse Power Rating:
- 30 hp
- Analogue Output Number:
- 1
- Product Certifications:
- NOM 117 || CSA || UL || C-tick
- Product Destination:
- asynchronous motors
- Assembly Style:
- with heat sink
- Power Dissipation In W:
- 723 W
- Switching Frequency:
- 6...16 kHz adjustable || 8...16 kHz with derating factor
- Accuracy:
- +/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C
- Data Format:
- 8 bits, 1 stop, odd even or no configurable parity
- Communication Service:
- read device identification (43) || monitoring inhibitable || time out setting from 0.1 to 100 s || read holding registers (03) 2 words maximum || write multiple registers (16) 2 words maximum || write single register (06)
- Pollution Degree:
- 3 IEC 61800-5-1
- Sustainable Offer Status:
- Green Premium product
- Communication Port Protocol:
- APOGEE FLN || Modbus || LonWorks || METASYS N2 || BACnet
- Mercury Free:
- Yes
- Option Card:
- communication card LonWorks
- Analogue Input Number:
- 2
- Transmission Frame:
- RTU
- Nominal Switching Frequency:
- 8 kHz
- Rohs Exemption Information:
- Yes
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Warranty:
- 18 months
- Sampling Duration:
- 2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
- Emc Filter:
- Class C2 EMC filter integrated
- Tightening Torque:
- 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) || 4.5 N.m, 40 lb.in L1/R, L2/S, L3/T)
- Environmental Disclosure:
- ENVPEP111244EN
- Speed Range:
- 45301
- Acceleration And Deceleration Ramps:
- linear adjustable separately from 0.01 to 3200 s || automatic based on the load
- Operating Altitude:
- 3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
- Depth:
- 190 mm
- Insulation Resistance:
- >= 1 mOhm 500 V DC for 1 minute
- [Us] Rated Supply Voltage:
- 380...480 V - 15...10 %
- Protection Type:
- overheating protection drive || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Supply Voltage Limits:
- 323-528 V
- Discrete Input Type:
- F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
- Minimum Switching Current:
- 3 mA 24 V DC configurable relay logic
- Type Of Polarization:
- no impedance
- Environmental Characteristic:
- classes 3C1 IEC 60721-3-3 || classes 3S2 IEC 60721-3-3
- Output Voltage:
- <= power supply voltage
- Regulation Loop:
- adjustable PI regulator
- Line Current:
- 41.1 A 380 V || 32.6 A 480 V
- Braking To Standstill:
- by DC injection
- Physical Interface:
- 2-wire RS 485
- Local Signalling:
- for DC bus energized 1 LED (red)
- Connector Type:
- 1 open style || 1 RJ45
- Electrical Connection:
- VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 25-25 mm² / AWG 3
- Air Flow:
- 214 m3/h
- Motor Slip Compensation:
- adjustable || automatic whatever the load || not available in voltage/frequency ratio motor control
- Product Specific Application:
- pumps and fans in HVAC
- Speed Drive Output Frequency:
- 0.5-200 Hz
- Analogue Input Type:
- VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
- Net Weight:
- 11.65 kg
- Discrete And Process Manufacturing:
- building - HVAC compressor for scroll || building - HVAC fan || building - HVAC pump
- Discrete Input Logic:
- positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
- Ip Degree Of Protection:
- IP20 on upper part without blanking plate on cover IEC 61800-5-1 || IP20 on upper part without blanking plate on cover IEC 60529 || IP21 IEC 61800-5-1 || IP21 IEC 60529 || IP41 on upper part IEC 61800-5-1 || IP41 on upper part IEC 60529
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Transient Overtorque:
- 120-120 % of nominal motor torque +/- 10 % 60 s
- Marking:
- CE
- Continuous Output Current:
- 43.5 A 380 V || 43.5 A 460 V
- Ambient Air Temperature For Operation:
- -10-40 °C without derating) || 40-50 °C with derating factor)
- Apparent Power:
- 27.3 kVA 380 V
- Power Range:
- 15-25 kW 380-440 V 3 phase || 15-25 kW 480-500 V 3 phase
- Number Of Addresses:
- 1-247
- Operating Position:
- vertical +/- 10 degree
- Frequency Resolution:
- display unit 0.1 Hz || analog input 0.024/50 Hz
- Electromagnetic Compatibility:
- electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
- Height:
- 330 mm
- Response Time:
- FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
- Maximum Switching Current:
- 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
- Phase:
- 3 phase
- Dielectric Strength:
- 3535 V DC between earth and power terminals || 5092 V DC between control and power terminals
- Maximum Transient Current:
- 47.9 A 60 s
- Discrete Output Type:
- configurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles
- Supply:
- internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
- Width:
- 245 mm
- Ambient Air Temperature For Storage:
- -25-70 °C
- Shock Resistance:
- 15 gn 11 ms IEC 60068-2-27
- Prospective Line Isc:
- 22 kA
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View