Schneider Electric ATV212HD30M3X Atv212 30Kw 40Hp 240Vtri Ss Cem Ip20 Var

(No reviews yet) Write a Review
SKU:
ATV212HD30M3X
UPC:
3606480322433
Condition:
New
Width:
320 mm
Communication Port Protocol:
METASYS N2 || APOGEE FLN || BACnet || LonWorks || Modbus
Motor Starter Type:
variable speed drive
Asynchronous Motor Control Profile:
voltage/frequency ratio, 2 points || voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || voltage/frequency ratio - Energy Saving, quadratic U/f || flux vector control without sensor, standard || voltage/frequency ratio, 5 point
Supply Frequency:
50...60 Hz - 5...5 %
Maximum Horse Power Rating:
40 hp
Operating Position:
vertical +/- 10 degree
Ambient Air Temperature For Storage:
-25-70 °C
Linearity Error:
VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
Environmental Characteristic:
classes 3C1 IEC 60721-3-3 || classes 3S2 IEC 60721-3-3
Option Card:
communication card LonWorks
Output Voltage:
<= power supply voltage
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Isolation:
electrical between power and control
Minimum Switching Current:
3 mA 24 V DC configurable relay logic
Discrete Output Number:
2
Transmission Frame:
RTU
Electrical Connection:
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 150-150 mm² 300 kcmil)
Pollution Degree:
3 IEC 61800-5-1
Ambient Air Temperature For Operation:
-10-40 °C without derating) || 40-50 °C with derating factor)
Type Of Polarization:
no impedance
Response Time:
FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
Prospective Line Isc:
22 kA
Line Current:
113.3 A 200 V || 89.5 A 240 V
Communication Service:
write multiple registers (16) 2 words maximum || monitoring inhibitable || time out setting from 0.1 to 100 s || read holding registers (03) 2 words maximum || read device identification (43) || write single register (06)
Rohs Exemption Information:
Yes
Supply:
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
Network Frequency:
47.5...63 Hz
Tightening Torque:
0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) || 41 N.m, 360 lb.in L1/R, L2/S, L3/T)
[Us] Rated Supply Voltage:
200...240 V - 15...10 %
Discrete Input Type:
F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
Number Of Addresses:
1-247
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Air Flow:
371 m3/h
Phase:
3 phase
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Speed Accuracy:
+/- 10 % of nominal slip 0.2 Tn to Tn
China Rohs Regulation:
X
Mercury Free:
Yes
Continuous Output Current:
117 A 230 V
Ip Degree Of Protection:
IP20 on upper part without blanking plate on cover IEC 61800-5-1 || IP20 on upper part without blanking plate on cover IEC 60529 || IP21 IEC 61800-5-1 || IP21 IEC 60529 || IP41 on upper part IEC 61800-5-1 || IP41 on upper part IEC 60529
Speed Drive Output Frequency:
0.5-200 Hz
Warranty:
18 months
Dielectric Strength:
2830 V DC between earth and power terminals || 4230 V DC between control and power terminals
Power Range:
30-50 kW 200-240 V 3 phase
Insulation Resistance:
>= 1 mOhm 500 V DC for 1 minute
Speed Range:
45301
Transmission Rate:
9600 bps or 19200 bps
Frequency Resolution:
display unit 0.1 Hz || analog input 0.024/50 Hz
Device Short Name:
ATV212
Discrete Output Type:
configurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles
Product Destination:
asynchronous motors
Supply Voltage Limits:
170-264 V
Physical Interface:
2-wire RS 485
Sustainable Offer Status:
Green Premium product
Analogue Input Number:
2
Assembly Style:
with heat sink
Marking:
CE
Braking To Standstill:
by DC injection
Noise Level:
63.7 dB 86/188/EEC
Accuracy:
+/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C
Discrete And Process Manufacturing:
building - HVAC compressor for scroll || building - HVAC fan || building - HVAC pump
Connector Type:
1 RJ45 || 1 open style
Vibration Resistance:
1.5 mm 3-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)EN/IEC 60068-2-8
Power Dissipation In W:
1085 W
Regulation Loop:
adjustable PI regulator
Motor Power Kw:
30 kW
Product Specific Application:
pumps and fans in HVAC
Motor Slip Compensation:
not available in voltage/frequency ratio motor control || adjustable || automatic whatever the load
Depth:
290 mm
Discrete Input Logic:
positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
Nominal Switching Frequency:
8 kHz
Protection Type:
overheating protection drive || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit
Specific Application:
HVAC
Product Or Component Type:
variable speed drive
Analogue Output Number:
1
Acceleration And Deceleration Ramps:
automatic based on the load || linear adjustable separately from 0.01 to 3200 s
Operating Altitude:
3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Maximum Transient Current:
128.7 A 60 s
Local Signalling:
for DC bus energized 1 LED (red)
Torque Accuracy:
+/- 15 %
Standards:
IEC 61800-3 environments 2 category C1 || IEC 61800-3 environments 2 category C2 || IEC 61800-3 environments 1 category C2 || IEC 61800-3 || IEC 61800-5-1 || IEC 61800-3 environments 1 category C3 || IEC 61800-3 environments 1 category C1 || UL Type
Apparent Power:
44.6 kVA 240 V
Height:
630 mm
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Relative Humidity:
5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
Analogue Input Type:
VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
Ip Degree Of Protection:
IP21
Range Of Product:
Altivar 212
Data Format:
8 bits, 1 stop, odd even or no configurable parity
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Transient Overtorque:
120-120 % of nominal motor torque +/- 10 % 60 s
Analogue Output Type:
FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits
Circularity Profile:
ENVEOLI110402EN
Maximum Switching Current:
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
Emc Filter:
without EMC filter
Sampling Duration:
2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
Type Of Cable:
without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
Net Weight:
38.65 kg
Switching Frequency:
6...16 kHz adjustable || 8...16 kHz with derating factor
Environmental Disclosure:
ENVPEP110404EN
Product Certifications:
NOM 117 || CSA || C-tick || UL
Brochure:
View
Catalog:
View
Datasheet:
View
$5,574.06

Description

This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21. It works at a rated power up to 30kW / 40hp and a rated voltage from 200V to 240V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 38.65kg and its dimensions are, 320mm wide, 630mm high, 290mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.