This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP55 and it has a built-in EMC filter. It works at a rated power up to 11kW / 15hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 30.3kg and its dimensions are, 290mm wide, 560mm high, 315mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.
- Marking:
- CE
- Physical Interface:
- 2-wire RS 485
- Sampling Duration:
- 2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
- Discrete Input Logic:
- positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
- Accuracy:
- +/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C
- Product Destination:
- asynchronous motors
- Standards:
- IEC 61800-3 environments 1 category C3 || IEC 61800-3 environments 1 category C2 || IEC 61800-3 category C2 || IEC 61800-3 environments 2 category C1 || IEC 61800-3 category C3 || IEC 61800-5-1 || IEC 61800-3 environments 1 category C1 || IEC 61800-3
- Tightening Torque:
- 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) || 3 N.m, 26.5 lb.in L1/R, L2/S, L3/T)
- Line Current:
- 16.9 A 480 V || 21.2 A 380 V
- Transient Overtorque:
- 120-120 % of nominal motor torque +/- 10 % 60 s
- Phase:
- 3 phase
- Isolation:
- electrical between power and control
- Product Specific Application:
- pumps and fans in HVAC
- [Us] Rated Supply Voltage:
- 380...480 V - 15...10 %
- Asynchronous Motor Control Profile:
- voltage/frequency ratio, 5 points || voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || voltage/frequency ratio - Energy Saving, quadratic U/f || flux vector control without sensor, standard || voltage/frequency ratio, 2 point
- Maximum Transient Current:
- 24.8 A 60 s
- Insulation Resistance:
- >= 1 mOhm 500 V DC for 1 minute
- Speed Accuracy:
- +/- 10 % of nominal slip 0.2 Tn to Tn
- Relative Humidity:
- 5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
- Option Card:
- communication card LonWorks
- Network Frequency:
- 47.5...63 Hz
- Regulation Loop:
- adjustable PI regulator
- Net Weight:
- 30.3 kg
- Response Time:
- FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
- Switching Frequency:
- 6...16 kHz adjustable || 12...16 kHz with derating factor
- Rohs Exemption Information:
- Yes
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Discrete Output Type:
- configurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles
- Product Or Component Type:
- variable speed drive
- Torque Accuracy:
- +/- 15 %
- Ambient Air Temperature For Operation:
- -10-40 °C without derating) || 40-50 °C with derating factor)
- Sustainable Offer Status:
- Green Premium product
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Electromagnetic Compatibility:
- electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
- Circularity Profile:
- ENVEOLI111252EN
- Discrete Input Type:
- F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
- Operating Position:
- vertical +/- 10 degree
- Local Signalling:
- for DC bus energized 1 LED (red)
- Operating Altitude:
- 3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
- Functionality:
- mid
- Noise Level:
- 57.4 dB 86/188/EEC
- Output Voltage:
- <= power supply voltage
- Environmental Characteristic:
- classes 3C1 IEC 60721-3-3 || classes 3S2 IEC 60721-3-3
- Ip Degree Of Protection:
- IP55
- Supply Frequency:
- 50...60 Hz - 5...5 %
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Communication Service:
- write multiple registers (16) 2 words maximum || read device identification (43) || time out setting from 0.1 to 100 s || write single register (06) || monitoring inhibitable || read holding registers (03) 2 words maximum
- Shock Resistance:
- 15 gn 11 ms IEC 60068-2-27
- Transmission Frame:
- RTU
- Number Of Addresses:
- 1-247
- Vibration Resistance:
- 1.5 mm 3-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)EN/IEC 60068-2-8
- Data Format:
- 8 bits, 1 stop, odd even or no configurable parity
- Type Of Polarization:
- no impedance
- Braking To Standstill:
- by DC injection
- Connector Type:
- 1 RJ45 || 1 open style
- Dielectric Strength:
- 3535 V DC between earth and power terminals || 5092 V DC between control and power terminals
- Nominal Switching Frequency:
- 12 kHz
- Type Of Cable:
- without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
- Pollution Degree:
- 2 IEC 61800-5-1
- Ip Degree Of Protection:
- IP55 IEC 61800-5-1 || IP55 IEC 60529
- Protection Type:
- overheating protection drive || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit
- Specific Application:
- HVAC
- Warranty:
- 18 months
- Frequency Resolution:
- display unit 0.1 Hz || analog input 0.024/50 Hz
- Environmental Disclosure:
- ENVPEP111264EN
- Motor Power Kw:
- 11 kW
- Analogue Output Type:
- FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits
- Maximum Horse Power Rating:
- 15 hp
- Linearity Error:
- VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
- Product Certifications:
- C-tick || UL || NOM 117 || CSA
- Acceleration And Deceleration Ramps:
- linear adjustable separately from 0.01 to 3200 s || automatic based on the load
- Supply Voltage Limits:
- 323-528 V
- Emc Filter:
- Class C2 EMC filter integrated
- Width:
- 290 mm
- Range Of Product:
- Altivar 212
- Transmission Rate:
- 9600 bps or 19200 bps
- Height:
- 560 mm
- Analogue Input Type:
- VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
- Discrete Output Number:
- 2
- Motor Slip Compensation:
- automatic whatever the load || adjustable || not available in voltage/frequency ratio motor control
- Apparent Power:
- 17.1 kVA 380 V
- Analogue Input Number:
- 2
- Supply:
- internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
- China Rohs Regulation:
- X
- Speed Drive Output Frequency:
- 0.5-200 Hz
- Communication Port Protocol:
- BACnet || METASYS N2 || Modbus || LonWorks || APOGEE FLN
- Mercury Free:
- Yes
- Minimum Switching Current:
- 3 mA 24 V DC configurable relay logic
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Depth:
- 315 mm
- Maximum Switching Current:
- 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
- Ambient Air Temperature For Storage:
- -25-70 °C
- Analogue Output Number:
- 1
- Continuous Output Current:
- 22.5 A 380 V || 22.5 A 460 V
- Device Short Name:
- ATV212
- Speed Range:
- 45301
- Prospective Line Isc:
- 22 kA
- Electrical Connection:
- VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 16-16 mm² / AWG 4
- Assembly Style:
- with heat sink
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View