- Environmental Class (During Operation):
- class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
- With Safety Function Safe Operating Stop (Sos):
- FALSE
- Marking:
- CE
- Sustainable Offer Status:
- Green Premium product
- Discrete Input Logic:
- 16 preset speeds
- Height:
- 660.0 mm
- Nominal Output Current:
- 61.5 A
- With Safety Function Safe Stop 1 (Ss1):
- TRUE
- Discrete Input Number:
- 8
- Range Of Product:
- Altivar Machine ATV340
- Nominal Switching Frequency:
- 4 kHz
- Operating Position:
- vertical +/- 10 degree
- Base Load Current At Low Overload:
- 74.5 A
- Pollution Degree:
- 2 IEC 61800-5-1
- Type Of Polarization:
- no impedance
- Analogue Input Number:
- 3
- Maximum Acceleration Under Vibrational Stress (During Operation):
- 10 m/s² at 13...200 Hz
- Power Dissipation In W:
- natural convection 77 W 380 V 4 kHz heavy duty) || forced convection 640 W 380 V 4 kHz heavy duty) || natural convection 90 W 380 V 4 kHz normal duty) || forced convection 796 W 380 V 4 kHz normal duty)
- Maximum Thdi:
- <48 % full load IEC 61000-3-12 || <48 % 80 % load IEC 61000-3-12
- Rohs Exemption Information:
- Yes
- Mounting Mode:
- wall mount
- With Safety Function Safe Brake Management (Sbc/Sbt):
- TRUE
- Switching Frequency:
- 2...16 kHz adjustable || 4...16 kHz with derating factor
- Pollution Degree:
- 2
- Electrical Connection:
- screw terminal 35...50 mm² line side || screw terminal 25...50 mm² DC bus || screw terminal 35...50 mm² motor || screw terminal 0.75...1.5 mm² control
- Width:
- 213.0 mm
- Product Or Component Type:
- variable speed drive
- Ambient Air Temperature For Storage:
- -40-70 °C
- Electrical Connection:
- line side screw terminal 35...50 mm² AWG 3...AWG 1 || DC bus screw terminal 25...50 mm² AWG 4...AWG 1 || motor screw terminal 35...50 mm² AWG 3...AWG 1 || control screw terminal 0.75...1.5 mm² AWG 18...AWG 16
- Motor Slip Compensation:
- automatic whatever the load || not available in permanent magnet motor law || adjustable || can be suppressed
- With Safety Function Safe Programmable Logic:
- FALSE
- Maximum Switching Current:
- relay output R1C resistive, cos phi = 1 3 A 250 V AC || relay output R1C resistive, cos phi = 1 3 A 30 V DC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R
- With Safety Function Safe Speed Monitor (Ssm):
- FALSE
- Operating Altitude:
- <= 4800 m with current derating above 1000m
- Isolation:
- between power and control terminals
- Type Of Cooling:
- forced convection
- Product Certifications:
- UL || CSA || TÃV || EAC || CTick
- Option Card:
- communication module, PROFINET || communication module, DeviceNet || communication module, CANopen || communication module, EtherCAT
- With Sft Fct Safe Stop 2 (Ss2):
- FALSE
- With Safety Function Safely Limited Position (Slp):
- FALSE
- Discrete Input Type:
- PTI safe torque off 0-30 kHz, 24 V DC 30 V) || DI1...DI5 programmable as pulse input, 24 V DC 30 V)3.5 kOhm || programmable
- Braking To Standstill:
- by DC injection
- With Safety Function Safe Position (Sp):
- FALSE
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Minimum Switching Current:
- relay output R1B 5 mA 24 V DC || relay output R2C 5 mA 24 V DC
- Asynchronous Motor Control Profile:
- variable torque standard || optimized torque mode || constant torque standard
- Mercury Free:
- Yes
- Ambient Air Transport Temperature:
- -40-70 °C
- Net Weight:
- 27.9 kg
- Base Load Current At High Overload:
- 61.5 A
- Maximum Output Frequency:
- 0.599 kHz
- Maximum Output Voltage:
- 480 V
- Environmental Disclosure:
- ENVPEP1411001EN
- Prospective Line Isc:
- 50 kA
- Maximum Deflection Under Vibratory Load (During Operation):
- 1.5 mm at 2...13 Hz
- Variant:
- standard version
- Line Current:
- 66.2 A 380 V normal duty) || 57.3 A 480 V normal duty) || 54.8 A 380 V heavy duty) || 48.3 A 480 V heavy duty)
- Discrete Output Number:
- 1
- Noise Level:
- 63.5 dB
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- With Safety Function Safely Limited Speed (Sls):
- TRUE
- Communication Port Protocol:
- EtherNet/IP || Modbus TCP || Modbus serial
- Apparent Power:
- 47.6 kVA 480 V normal duty) || 40.2 kVA 480 V heavy duty)
- Number Of Addresses:
- 1-247
- Overvoltage Category:
- class III
- Physical Interface:
- 2-wire RS 485
- Analogue Output Number:
- 2
- Upgradeability:
- Upgraded components available
- Regulation Loop:
- adjustable PID regulator
- Brake Chopper Integrated:
- TRUE
- Permitted Relative Humidity (During Operation):
- class 3K5 according to EN 60721-3
- [Us] Rated Supply Voltage:
- 380...480 V - 15...10 %
- Protection Type:
- thermal protection motor || safe torque off motor || motor phase loss motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent drive || output overcurrent between motor phase and earth drive || output overcurrent
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Synchronous Motor Control Profile:
- reluctance motor || permanent magnet motor
- Motor Power Kw:
- 37 kW normal duty || 30 kW heavy duty
- Maximum Horse Power Rating:
- 50 hp normal duty || 40 hp heavy duty
- Emc Filter:
- class C3 EMC filter integrated
- Degree Of Protection:
- UL type 1
- Maximum Transient Current:
- 89.4 A 60 s normal duty) || 89.4 A 2 s normal duty) || 92.3 A 60 s heavy duty) || 92.3 A 2 s heavy duty)
- Phase:
- 3 phase
- Transmission Frame:
- RTU
- With Safety Function Safe Torque Off (Sto):
- TRUE
- Depth:
- 262.0 mm
- Relay Output Number:
- 3
- 4 Quadrant Operation Possible:
- TRUE
- Assembly Style:
- with heat sink
- China Rohs Regulation:
- X
- Maximum Acceleration Under Shock Impact (During Operation):
- 150 m/s² at 11 ms
- Ambient Air Temperature For Operation:
- -15-50 °C without derating vertical position) || 50-60 °C with derating factor vertical position)
- Line Current:
- 66.2 A 380 V with internal line choke normal duty) || 57.3 A 480 V with internal line choke normal duty) || 66.2 A 380 V with internal line choke heavy duty) || 57.3 A 480 V with internal line choke heavy duty) || 54.8 A || 48.3 A
- Method Of Access:
- slave Modbus RTU || slave Modbus TCP
- Volume Of Cooling Air:
- 240.0 m3/h
- Circularity Profile:
- ENVEOLI1411001EN
- Connector Type:
- 3 RJ45
- Relay Output Type:
- relay outputs R1A || relay outputs R1C 100000 cycles || relay outputs R2A || relay outputs R2C 100000 cycles
- With Safety Function Safe Direction (Sdi):
- FALSE
- Analogue Output Type:
- software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
- Output Voltage:
- <= power supply voltage
- Acceleration And Deceleration Ramps:
- linear adjustable separately from 0.01...9999 s || S, U or customized
- Electromagnetic Compatibility:
- electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
- Standards:
- IEC 61800-3 || IEC 61800-5-1 || IEC 60721-3 || IEC 61508 || IEC 13849-1 || UL 618000-5-1 || UL 508C || IEC 61000-3-12
- Analogue Input Type:
- AI1 software-configurable current 0...20 mA 250 Ohm 12 bits || AI1 software-configurable temperature probe or water level sensor || AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI2 software-configurable voltage - 10...10 V DC 31
- Supply Frequency:
- 50...60 Hz +/- 5 %
- Ip Degree Of Protection:
- IP20
- Transmission Rate:
- 4.8 kbit/s || 9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s
- Continuous Output Current:
- 74.5 A 4 kHz normal duty || 61.5 A 4 kHz heavy duty
- Product Specific Application:
- machine
- Data Format:
- 8 bits, configurable odd, even or no parity
- Discrete Output Type:
- programmable output DQ1, DQ2 30 V DC 100 mA