Emc Filter:
integrated 25 m IEC 61800-3 category C3
Local Signalling:
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Motor Slip Compensation:
not available in permanent magnet motor law || can be suppressed || automatic whatever the load || adjustable
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Standards:
UL 508C || IEC 61800-3 || EN/IEC 61800-3 environment 2 category C3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Variant:
standard version
Apparent Power:
22.9 kVA 690 V normal duty) || 17.6 kVA 690 V heavy duty)
[Us] Rated Supply Voltage:
500...690 V - 15...10 %
Product Or Component Type:
variable speed drive
Line Current:
18.4 A 500 V normal duty) || 19.2 A 690 V normal duty) || 13.6 A 500 V heavy duty) || 14.7 A 690 V heavy duty)
Switching Frequency:
2...8 kHz adjustable || 4...8 kHz with derating factor
Depth:
242 mm
China Rohs Regulation:
X
Maximum Horse Power Rating:
15 hp 500 V normal duty || 10 hp 500 V heavy duty || 20 hp 690 V normal duty || 15 hp 690 V heavy duty
Transmission Frame:
RTU
Noise Level:
58 dB
Pollution Degree:
2
Mounting Mode:
wall mount
Communication Port Protocol:
Modbus TCP || Ethernet || Modbus serial
Prospective Line Isc:
70 kA
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Phase:
3 phase
Discrete Output Number:
0
Method Of Access:
slave Modbus TCP
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Braking To Standstill:
by DC injection
Circularity Profile:
ENVEOLI1704001EN
Maximum Output Frequency:
500 kHz
Relay Output Number:
3
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Type Of Polarization:
no impedance
Ip Degree Of Protection:
IP00IEC 61800-5-1 || IP00IEC 60529 || IP20 with kit VW3A9705)IEC 61800-5-1 || IP20 with kit VW3A9705)IEC 60529
Acceleration And Deceleration Ramps:
S, U or customized || linear adjustable separately from 0.01...9999 s
Upgradeability:
Upgraded components available
Discrete Input Number:
8
Product Specific Application:
process and utilities
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Height:
420 mm
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immu
Continuous Output Current:
18 A 4 kHz normal duty || 13.5 A 4 kHz heavy duty
Maximum Transient Current:
19.8 A 60 s normal duty) || 20.3 A 60 s heavy duty)
Enclosure Mounting:
wall mounted
Option Card:
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
Range Of Product:
Altivar Process ATV600
Product Destination:
asynchronous motors || synchronous motors
Isolation:
between power and control terminals
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Mercury Free:
Yes
Input Compatibility:
DI1...DI6 discrete input level 1 PLC IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Analogue Input Number:
3
Overvoltage Category:
III
Regulation Loop:
adjustable PID regulator
Sustainable Offer Status:
Green Premium product
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Speed Drive Output Frequency:
0.1-500 Hz
Pollution Degree:
2 IEC 61800-5-1
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Output Voltage:
<= power supply voltage
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Analogue Output Number:
2
Noise Level:
52 dB 86/188/EEC
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Marking:
CE
Supply Frequency:
50...60 Hz - 5...5 %
Width:
246 mm
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Device Short Name:
ATV630
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 6...10 mm² AWG 10...AWG 8 || line side screw terminal 6...10 mm² AWG 10...AWG 8
Environmental Disclosure:
ENVPEP1704001EN
Ambient Air Temperature For Storage:
-40-70 °C
Power Dissipation In W:
natural convection 110 W 500 V 4 kHz || forced convection 271 W 500 V 4 kHz
Data Format:
8 bits, configurable odd, even or no parity
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Nominal Switching Frequency:
4 kHz
Asynchronous Motor Control Profile:
optimized torque mode || constant torque standard || variable torque standard
Net Weight:
22 kg
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Quantity Per Set:
1
Number Of Addresses:
1-247 Modbus serial
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Rohs Exemption Information:
Yes
Physical Interface:
Ethernet || 2-wire RS 485
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Frequency Resolution:
display unit 0.1 Hz || analog input 0.012/50 Hz
Safety Function:
STO (safe torque off) SIL 3
Permissible Temporary Current Boost:
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
[Us] Rated Supply Voltage:
500...690 V
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Type Of Cooling:
forced convection
Motor Power Kw:
11 kW 500 V normal duty) || 7.5 kW 500 V heavy duty) || 15 kW 690 V normal duty) || 11 kW 690 V heavy duty)
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Operating Position:
vertical +/- 10 degree
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Product Certifications:
CSA || TÜV || UL
Discrete Input Logic:
16 preset speeds
Maximum Thdi:
<48 % with external line choke IEC 61000-3-12
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Volume Of Cooling Air:
330 m3/h
  • Schneider Electric ATV630D15Y6 Atv630Ip00 15Kw 500V-690V Variable Spee
  • Schneider Electric ATV630D15Y6 Atv630Ip00 15Kw 500V-690V Variable Spee
$4,742.36

Description

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 500V to 690V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 15kW / 20hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 11kW / 15hp for applications requiring significant overload (up to 150%). It weighs 22kg and its dimensions are, 246mm wide, 420mm high, 242mm deep. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.