Schneider Electric ATV630D18S6 Atv630Ip20 25Hp 600V Variable Speed Dri
SKU:
ATV630D18S6
UPC:
3606481324894
MPN:
Condition:
New
Overvoltage Category:
III
Discrete Output Number:
0
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Quantity Per Set:
1
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Degree Of Protection:
UL type 1 UL 508C
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Environmental Disclosure:
ENVPEP1704001EN
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Product Certifications:
TÃV || CSA || UL
Range Of Product:
Altivar Process ATV600
Communication Port Protocol:
Modbus TCP || Modbus serial || Ethernet
Switching Frequency:
2...8 kHz adjustable || 4...8 kHz with derating factor
Product Destination:
asynchronous motors || synchronous motors
Method Of Access:
slave Modbus TCP
Apparent Power:
24.1 kVA 600 V normal duty) || 20.4 kVA 600 V heavy duty)
[Us] Rated Supply Voltage:
600 V
Operating Position:
vertical +/- 10 degree
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 10 mm² AWG 8 || line side screw terminal 10 mm² AWG 8
Depth:
242 mm
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Braking To Standstill:
by DC injection
China Rohs Regulation:
X
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Marking:
CE
Line Current:
23.2 A 600 V normal duty) || 19.6 A 600 V heavy duty)
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
Continuous Output Current:
27 A 4 kHz normal duty || 22 A 4 kHz heavy duty
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Phase:
3 phase
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Variant:
standard version
Analogue Output Number:
2
Data Format:
8 bits, configurable odd, even or no parity
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Power Dissipation In W:
natural convection 125 W 600 V 4 kHz || forced convection 377 W 600 V 4 kHz
Safety Function:
STO (safe torque off) SIL 3
Ambient Air Temperature For Storage:
-40-70 °C
Product Specific Application:
process and utilities
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
automatic whatever the load || adjustable || can be suppressed || not available in permanent magnet motor law
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Mounting Mode:
wall mount
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Emc Filter:
without EMC filter
Type Of Cooling:
forced convection
Isolation:
between power and control terminals
Nominal Switching Frequency:
4 kHz
Discrete Input Number:
8
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Maximum Output Frequency:
500 kHz
Maximum Transient Current:
29.7 A 60 s normal duty) || 33 A 60 s heavy duty)
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Number Of Addresses:
1-247 Modbus serial
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Discrete Input Logic:
16 preset speeds
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Upgradeability:
Upgraded components available
Relay Output Number:
3
Permissible Temporary Current Boost:
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
Local Signalling:
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Speed Drive Output Frequency:
0.1-500 Hz
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Asynchronous Motor Control Profile:
optimized torque mode || constant torque standard || variable torque standard