Schneider Electric

Schneider Electric ATV630D37Y6 Atv630Ip00 37Kw 500V-690V Variable Spee

(No reviews yet) Write a Review
SKU:
ATV630D37Y6
UPC:
3.60648E+12
Condition:
New
Braking To Standstill:
by DC injection
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Speed Drive Output Frequency:
0.1-500 Hz
Output Voltage:
<= power supply voltage
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Power Dissipation In W:
natural convection 178 W 500 V 2.5 kHz || forced convection 557 W 500 V 2.5 kHz
Motor Slip Compensation:
not available in permanent magnet motor law || automatic whatever the load || adjustable || can be suppressed
Ambient Air Temperature For Storage:
-40-70 °C
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Isolation:
between power and control terminals
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Product Destination:
asynchronous motors || synchronous motors
Phase:
3 phase
Motor Power Kw:
30 kW 500 V normal duty) || 22 kW 500 V heavy duty) || 37 kW 690 V normal duty) || 30 kW 690 V heavy duty)
Regulation Loop:
adjustable PID regulator
Upgradeability:
Upgraded components available
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Us] Rated Supply Voltage:
500...690 V - 15...10 %
Device Short Name:
ATV630
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Maximum Output Frequency:
500 kHz
Apparent Power:
55.2 kVA 690 V normal duty) || 46 kVA 690 V heavy duty)
Type Of Polarization:
no impedance
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Marking:
CE
Frequency Resolution:
display unit 0.1 Hz || analog input 0.012/50 Hz
Variant:
standard version
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Emc Filter:
integrated 25 m IEC 61800-3 category C3
Volume Of Cooling Air:
406 m3/h
Method Of Access:
slave Modbus TCP
Line Current:
47.2 A 500 V normal duty) || 46.2 A 690 V normal duty) || 37.7 A 500 V heavy duty) || 38.5 A 690 V heavy duty)
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Communication Port Protocol:
Modbus TCP || Modbus serial || Ethernet
Depth:
297 mm
Discrete Output Number:
0
Circularity Profile:
ENVEOLI1706016EN
Sustainable Offer Status:
Green Premium product
Maximum Transient Current:
51 A 60 s heavy duty) || 49.5 A 60 s normal duty)
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Net Weight:
53 kg
Environmental Disclosure:
ENVPEP1706016EN
Operating Position:
vertical +/- 10 degree
Maximum Horse Power Rating:
40 hp 500 V normal duty || 30 hp 500 V heavy duty || 50 hp 690 V normal duty || 40 hp 690 V heavy duty
Asynchronous Motor Control Profile:
variable torque standard || optimized torque mode || constant torque standard
Discrete Input Logic:
16 preset speeds
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Acceleration And Deceleration Ramps:
S, U or customized || linear adjustable separately from 0.01...9999 s
Number Of Addresses:
1-247 Modbus serial
Noise Level:
52 dB 86/188/EEC
Analogue Input Number:
3
Overvoltage Category:
III
Safety Function:
STO (safe torque off) SIL 3
Product Specific Application:
process and utilities
Noise Level:
56 dB
Switching Frequency:
1...4.9 kHz adjustable || 2.5...4.9 kHz with derating factor
Permissible Temporary Current Boost:
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
Input Compatibility:
DI1...DI6 discrete input level 1 PLC IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation:
X
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Mounting Mode:
wall mount
Product Or Component Type:
variable speed drive
Quantity Per Set:
1
Transmission Frame:
RTU
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Nominal Switching Frequency:
2.5 kHz
Mercury Free:
Yes
Option Card:
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
[Us] Rated Supply Voltage:
500...690 V
Enclosure Mounting:
wall mounted
Pollution Degree:
2
Physical Interface:
Ethernet || 2-wire RS 485
Product Certifications:
CSA || TÜV || UL
Prospective Line Isc:
70 kA
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Data Format:
8 bits, configurable odd, even or no parity
Discrete Input Number:
8
Width:
331 mm
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Ip Degree Of Protection:
IP00IEC 61800-5-1 || IP00IEC 60529 || IP20 with kit VW3A9706)IEC 61800-5-1 || IP20 with kit VW3A9706)IEC 60529
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Pollution Degree:
2 IEC 61800-5-1
Continuous Output Current:
34 A 2.5 kHz heavy duty || 45 A 2.5 kHz normal duty
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Standards:
UL 508C || IEC 61800-3 || EN/IEC 61800-3 environment 2 category C3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Height:
630 mm
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 16...50 mm² AWG 6...AWG 1 || line side screw terminal 16...50 mm² AWG 6...AWG 1
Range Of Product:
Altivar Process ATV600
Type Of Cooling:
forced convection
Analogue Output Number:
2
Rohs Exemption Information:
Yes
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Relay Output Number:
3
Supply Frequency:
50...60 Hz - 5...5 %
Maximum Thdi:
<48 % with external line choke IEC 61000-3-12
Local Signalling:
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Brochure:
View
Catalog:
View
Datasheet:
View
$9,225.48

Description

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. This variable speed drive features an integrated EMC filter with 25m cable conforming to category C3. It works at a rated supply voltage from 500V to 690VAC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 37kW/50HP for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 30kW/40HP for applications requiring significant overload (up to 150%). Its dimensions are 331mm (width) x 297mm (depth) x 630mm (height). It weighs 53kg. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. This product is certified by CE, CSA and TUV. It meets UL 508C, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508 and IEC 13849-1 standards. Accessories (fan kit, graphic display terminal) and options (line chokes, dv/dt filter, sinus filter, EMC filter) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
View AllClose