Schneider Electric

Schneider Electric ATV630D45S6 Atv630Ip20 60Hp 600V Variable Speed Dri

(No reviews yet) Write a Review
SKU:
ATV630D45S6
UPC:
3.60648E+12
Condition:
New
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Noise Level:
52 dB 86/188/EEC
Phase:
3 phase
Ip Degree Of Protection:
IP20IEC 61800-5-1 || IP20IEC 60529
Nominal Switching Frequency:
2.5 kHz
Environmental Disclosure:
ENVPEP1706016EN
Type Of Cooling:
forced convection
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Input Compatibility:
DI1...DI6 discrete input level 1 PLC IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Number Of Addresses:
1-247 Modbus serial
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Method Of Access:
slave Modbus TCP
Apparent Power:
57.3 kVA 600 V normal duty) || 48.9 kVA 600 V heavy duty)
Discrete Output Number:
0
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Net Weight:
55 kg
Noise Level:
56 dB
Analogue Input Number:
3
Circularity Profile:
ENVEOLI1706016EN
Power Dissipation In W:
natural convection 205 W 600 V 2.5 kHz || forced convection 728 W 600 V 2.5 kHz
Speed Drive Output Frequency:
0.1-500 Hz
[Us] Rated Supply Voltage:
600 V - 15...10 %
Sustainable Offer Status:
Green Premium product
Motor Slip Compensation:
can be suppressed || automatic whatever the load || not available in permanent magnet motor law || adjustable
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 25...50 mm² AWG 4...AWG 1 || motor screw terminal 25...50 mm² AWG 4...AWG 1
Maximum Transient Current:
68.2 A 60 s normal duty) || 78 A 60 s heavy duty)
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s || S, U or customized
Range Of Product:
Altivar Process ATV600
Mounting Mode:
wall mount
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Supply Frequency:
50...60 Hz - 5...5 %
Upgradeability:
Upgraded components available
Analogue Output Number:
2
Pollution Degree:
2
Option Card:
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
Variant:
standard version
Emc Filter:
without EMC filter
Line Current:
55.1 A 600 V normal duty) || 47.1 A 600 V heavy duty)
Overvoltage Category:
III
Depth:
297 mm
[Us] Rated Supply Voltage:
600 V
Maximum Thdi:
<48 % with external line choke IEC 61000-3-12
Communication Port Protocol:
Ethernet || Modbus serial || Modbus TCP
Enclosure Mounting:
wall mounted
Width:
331 mm
Safety Function:
STO (safe torque off) SIL 3
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Relay Output Number:
3
Maximum Output Frequency:
500 kHz
Braking To Standstill:
by DC injection
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Maximum Horse Power Rating:
60 hp 600 V normal duty || 50 hp 600 V heavy duty
Product Certifications:
TÜV || CSA || UL
Permissible Temporary Current Boost:
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
Physical Interface:
Ethernet || 2-wire RS 485
Mercury Free:
Yes
Discrete Input Number:
8
Pollution Degree:
2 IEC 61800-5-1
Degree Of Protection:
UL type 1 UL 508C
Transmission Frame:
RTU
Data Format:
8 bits, configurable odd, even or no parity
Ambient Air Temperature For Storage:
-40-70 °C
Marking:
CE
Product Destination:
asynchronous motors || synchronous motors
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Asynchronous Motor Control Profile:
constant torque standard || variable torque standard || optimized torque mode
Prospective Line Isc:
70 kA
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Device Short Name:
ATV630
Type Of Polarization:
no impedance
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Local Signalling:
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Height:
822 mm
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Switching Frequency:
1...4.9 kHz adjustable || 2.5...4.9 kHz with derating factor
Quantity Per Set:
1
Volume Of Cooling Air:
406 m3/h
Operating Position:
vertical +/- 10 degree
Regulation Loop:
adjustable PID regulator
Rohs Exemption Information:
Yes
Frequency Resolution:
display unit 0.1 Hz || analog input 0.012/50 Hz
China Rohs Regulation:
X
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Product Or Component Type:
variable speed drive
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Discrete Input Logic:
16 preset speeds
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Continuous Output Current:
62 A 2.5 kHz normal duty || 52 A 2.5 kHz heavy duty
Isolation:
between power and control terminals
Output Voltage:
<= power supply voltage
Product Specific Application:
process and utilities
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Datasheet:
View
$10,153.26