Schneider Electric ATV630D75M3 Variable Speed Drive Ip21 75Kw 200V/240V

(No reviews yet) Write a Review
SKU:
ATV630D75M3
UPC:
3.60648E+12
Condition:
New
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Product Destination:
asynchronous motors || synchronous motors
Pollution Degree:
2
Communication Port Protocol:
Modbus serial || Ethernet || Modbus TCP
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Method Of Access:
slave Modbus TCP
Ambient Air Temperature For Storage:
-40-70 °C
Product Specific Application:
process and utilities
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Net Weight:
84 kg
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Safety Function:
STO (safe torque off) SIL 3
Device Short Name:
ATV630
Output Voltage:
<= power supply voltage
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Local Signalling:
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Upgradeability:
Upgraded components available
Rohs Exemption Information:
Yes
Ip Degree Of Protection:
IP00IEC 61800-5-1 || IP00IEC 60529 || IP21 with kit VW3A9704)IEC 61800-5-1 || IP21 with kit VW3A9704)IEC 60529
Analogue Input Number:
3
Option Card:
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
Asynchronous Motor Control Profile:
constant torque standard || optimized torque mode || variable torque standard
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
China Rohs Regulation:
X
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 2 x 95...3 x 120 mm² 2 x AWG 3/0...2 x 300 kcmil || motor screw terminal 2 x 95...3 x 120 mm² 2 x AWG 3/0...2 x 300 kcmil
Nominal Switching Frequency:
2.5 kHz
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
[Us] Rated Supply Voltage:
200...240 V
Discrete Output Number:
0
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Supply Frequency:
50...60 Hz - 5...5 %
Motor Power Kw:
75 kW normal duty) || 55 kW heavy duty)
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Type Of Cooling:
forced convection
Frequency Resolution:
display unit 0.1 Hz || analog input 0.012/50 Hz
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Noise Level:
69.9 dB
Overvoltage Category:
III
Operating Position:
vertical +/- 10 degree
Volume Of Cooling Air:
600 m3/h
Variant:
standard version
Power Range:
55-100 kW 200-240 V 3 phase
Relay Output Number:
3
Transmission Frame:
RTU
Input Compatibility:
DI1...DI6 discrete input level 1 PLC IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Continuous Output Current:
211 A 2.5 kHz heavy duty || 282 A 2.5 kHz normal duty
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Mounting Mode:
wall mount
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Maximum Horse Power Rating:
100 hp normal duty || 75 hp heavy duty
Circularity Profile:
ENVEOLI1501011EN
Isolation:
between power and control terminals
Apparent Power:
83.7 kVA 240 V normal duty) || 61.1 kVA 240 V heavy duty)
Mercury Free:
Yes
Product Or Component Type:
variable speed drive
Discrete Input Logic:
16 preset speeds
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Regulation Loop:
adjustable PID regulator
Environmental Disclosure:
ENVPEP1501011EN
Phase:
3 phase
Type Of Polarization:
no impedance
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Depth:
390 mm
Enclosure Mounting:
wall mounted
Data Format:
8 bits, configurable odd, even or no parity
Braking To Standstill:
by DC injection
Permissible Temporary Current Boost:
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
[Us] Rated Supply Voltage:
200...240 V - 15...10 %
Switching Frequency:
2.5...8 kHz with derating factor || 2...8 kHz adjustable
Quantity Per Set:
1
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Physical Interface:
Ethernet || 2-wire RS 485
Marking:
CE
Noise Level:
69.9 dB 86/188/EEC
Number Of Addresses:
1-247 Modbus serial
Maximum Thdi:
<48 % full load IEC 61000-3-12
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Emc Filter:
without EMC filter
Motor Slip Compensation:
automatic whatever the load || not available in permanent magnet motor law || can be suppressed || adjustable
Width:
320 mm
Discrete And Process Manufacturing:
building - HVAC compressor centrifugal || food and beverage processing other application || mining mineral and metal fan || mining mineral and metal pump || oil and gas fan || water and waste water other application || building - HVAC screw compresso
Standards:
UL 508C || IEC 61800-3 || IEC 61800-3 environment 1 category C2 || EN/IEC 61800-3 environment 2 category C3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Maximum Output Frequency:
500 kHz
Discrete Input Number:
8
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Pollution Degree:
2 IEC 61800-5-1
Prospective Line Isc:
50 kA
Height:
852 mm
Sustainable Offer Status:
Green Premium product
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Range Of Product:
Altivar Process ATV600
Analogue Output Number:
2
Product Certifications:
UL || DNV-GL || TÜV || CSA || ATEX zone 2/22 || ATEX INERIS
Speed Drive Output Frequency:
0.1-500 Hz
Maximum Transient Current:
310.2 A 60 s normal duty) || 316.5 A 60 s heavy duty)
Line Current:
256 A 200 V normal duty) || 215 A 240 V normal duty) || 189 A 200 V heavy duty) || 161 A 240 V heavy duty)
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric ATV630D75M3 Variable Speed Drive Ip21 75Kw 200V/240V
  • Schneider Electric ATV630D75M3 Variable Speed Drive Ip21 75Kw 200V/240V
  • Schneider Electric ATV630D75M3 Variable Speed Drive Ip21 75Kw 200V/240V
$15,631.16

Description

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 200V to 240V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 75kW / 100hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 55kW / 75hp for applications requiring significant overload (up to 150%). It weighs 84kg and its dimensions are, 320mm wide, 852mm high, 390mm deep. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
View AllClose