Schneider Electric

Schneider Electric ATV630U75M3 Variable Speed Drive Ip21 7,5Kw 200V/240

(No reviews yet) Write a Review
SKU:
ATV630U75M3
UPC:
3606485406930
Condition:
New
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Analogue Input Number:
3
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Net Weight:
13.8 kg
Mercury Free:
Yes
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Sustainable Offer Status:
Green Premium product
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Environmental Disclosure:
ENVPEP1404008EN
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Apparent Power:
9.4 kVA 240 V normal duty) || 7 kVA 240 V heavy duty)
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
[Us] Rated Supply Voltage:
200...240 V
Ambient Air Temperature For Storage:
-40-70 °C
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Maximum Transient Current:
38.1 A 60 s heavy duty) || 36 A 60 s normal duty)
Product Certifications:
DNV-GL || UL || ATEX zone 2/22 || CSA || ATEX INERIS || TÜV
Discrete And Process Manufacturing:
building - HVAC compressor centrifugal || food and beverage processing other application || mining mineral and metal fan || mining mineral and metal pump || oil and gas fan || water and waste water other application || building - HVAC screw compresso
Degree Of Protection:
UL type 1 UL 508C
Safety Function:
STO (safe torque off) SIL 3
Local Signalling:
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Noise Level:
59.5 dB 86/188/EEC
Product Specific Application:
process and utilities
Enclosure Mounting:
wall mounted
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Marking:
CE
Supply Frequency:
50...60 Hz - 5...5 %
Width:
211 mm
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Rohs Exemption Information:
Yes
Method Of Access:
slave Modbus TCP
Noise Level:
59.5 dB
Motor Power Kw:
7.5 kW normal duty) || 5.5 kW heavy duty)
Discrete Output Number:
0
Product Destination:
asynchronous motors || synchronous motors
Maximum Output Frequency:
500 kHz
Quantity Per Set:
1
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Output Voltage:
<= power supply voltage
Variant:
standard version
Maximum Horse Power Rating:
10 hp normal duty || 7.5 hp heavy duty
Frequency Resolution:
display unit 0.1 Hz || analog input 0.012/50 Hz
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Discrete Input Number:
8
Discrete Input Logic:
16 preset speeds
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Pollution Degree:
2 IEC 61800-5-1
Physical Interface:
Ethernet || 2-wire RS 485
Overvoltage Category:
III
Relay Output Number:
3
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Upgradeability:
Upgraded components available
Height:
546 mm
Switching Frequency:
2...12 kHz adjustable || 4...12 kHz with derating factor
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Motor Slip Compensation:
adjustable || not available in permanent magnet motor law || can be suppressed || automatic whatever the load
Input Compatibility:
DI1...DI6 discrete input level 1 PLC IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Isolation:
between power and control terminals
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Number Of Addresses:
1-247 Modbus serial
Braking To Standstill:
by DC injection
Pollution Degree:
2
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Data Format:
8 bits, configurable odd, even or no parity
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Power Range:
7-11 kW 200-240 V 3 phase
Continuous Output Current:
32.7 A 4 kHz normal duty || 25.4 A 4 kHz heavy duty
Range Of Product:
Altivar Process ATV600
Operating Position:
vertical +/- 10 degree
Phase:
3 phase
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mounting Mode:
wall mount
Transmission Frame:
RTU
Speed Drive Output Frequency:
0.1-500 Hz
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Power Dissipation In W:
forced convection 53 W 200 V 4 kHz || natural convection 254 W 200 V 4 kHz
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Product Or Component Type:
variable speed drive
Regulation Loop:
adjustable PID regulator
Depth:
232 mm
Option Card:
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Ip Degree Of Protection:
IP21IEC 61800-5-1 || IP21IEC 60529
Permissible Temporary Current Boost:
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 10...16 mm² AWG 8...AWG 6 || motor screw terminal 10...16 mm² AWG 8...AWG 6
China Rohs Regulation:
X
Line Current:
27.1 A 200 V normal duty) || 22.8 A 240 V normal duty) || 20.2 A 200 V heavy duty) || 17.1 A 240 V heavy duty)
Standards:
UL 508C || IEC 61800-3 || IEC 61800-3 environment 1 category C2 || EN/IEC 61800-3 environment 2 category C3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Type Of Cooling:
forced convection
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Nominal Switching Frequency:
4 kHz
Prospective Line Isc:
50 kA
Emc Filter:
without EMC filter
Circularity Profile:
ENVEOLI1404008EN
Asynchronous Motor Control Profile:
optimized torque mode || variable torque standard || constant torque standard
Analogue Output Number:
2
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Communication Port Protocol:
Ethernet || Modbus serial || Modbus TCP
Device Short Name:
ATV630
Type Of Polarization:
no impedance
Volume Of Cooling Air:
103 m3/h
[Us] Rated Supply Voltage:
200...240 V - 15...10 %
Brochure:
View
Catalog:
View
Datasheet:
View
$3,102.35

Description

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 200V to 240V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 7.5kW / 10hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 5.5kW / 7.5hp for applications requiring significant overload (up to 150%). It weighs 13.8kg and its dimensions are, 211mm wide, 546mm high, 232mm deep. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
View AllClose