Schneider Electric

Schneider Electric ATV650D30N4U Atv650 Ip55 Ul Type12 30Kw 40Hp 400V/480

(No reviews yet) Write a Review
SKU:
ATV650D30N4U
UPC:
3.60648E+12
Condition:
New
Regulation Loop:
adjustable PID regulator
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Output Voltage:
<= power supply voltage
Circularity Profile:
ENVEOLI1506001EN
Connector Type:
RJ45 on the remote graphic terminal)Modbus serial || RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Emc Filter:
integrated 50 m IEC 61800-3 category C2 || integrated 150 m IEC 61800-3 category C3
Speed Drive Output Frequency:
0.1-500 Hz
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Synchronous Motor Control Profile:
synchronous reluctance motor || permanent magnet motor
China Rohs Regulation:
X
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R1, R2, R3 resistive, cos phi = 1 3
Discrete Input Logic:
16 preset speeds
Electromagnetic Compatibility:
radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Net Weight:
50 kg
Method Of Access:
slave Modbus TCP
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Product Or Component Type:
variable speed drive
Quantity Per Set:
1
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Sustainable Offer Status:
Green Premium product
Environmental Disclosure:
ENVPEP1506001EN
Operating Position:
vertical +/- 10 degree
Safety Function:
STO (safe torque off) SIL 3
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Switching Frequency:
4...12 kHz with derating factor || 2...12 kHz adjustable
Type Of Polarization:
no impedance
[Us] Rated Supply Voltage:
380...480 V
Type Of Cooling:
forced convection
Discrete Input Number:
8
Upgradeability:
Upgraded components available
Marking:
CE
Option Card:
slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A communication module, CANopen SUB-D 9 || slot A
Product Specific Application:
process and utilities
Noise Level:
69.7 dB 86/188/EEC
Isolation:
between power and control terminals
Data Format:
8 bits, configurable odd, even or no parity
Communication Port Protocol:
Ethernet || Modbus serial
Analogue Output Number:
2
Maximum Output Frequency:
500 kHz
Ambient Air Temperature For Storage:
-40-70 °C
Pollution Degree:
3
Permissible Temporary Current Boost:
1.5 x In 60 s heavy duty) || 1.1 x In 60 s normal duty)
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Motor Slip Compensation:
automatic whatever the load || adjustable || can be suppressed
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Mounting Mode:
wall mount
Nominal Switching Frequency:
4 kHz
Width:
290 mm
Number Of Addresses:
1-247 Modbus serial
Pollution Degree:
2 IEC 61800-5-1
Ip Degree Of Protection:
IP55IEC 60529 || IP55IEC 61800-5-1
Local Signalling:
for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red) || for local diagnostic 3 LEDs
Degree Of Protection:
UL type 12 UL 508C
Linearity Error:
AO1, AO2 +/- 0.2 % analog output || AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
Range Of Product:
Altivar Process ATV600
Product Destination:
asynchronous motors || synchronous motors
Accuracy:
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output || +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
Physical Interface:
Ethernet || 2-wire RS 485
Supply:
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection || external suppl
Maximum Horse Power Rating:
30 hp heavy duty || 40 hp normal duty
Electrical Connection:
motor screw terminal 25...50 mm² || line side screw terminal 25...50 mm² || control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
Continuous Output Current:
59 A 4 kHz normal duty || 46.3 A 4 kHz heavy duty
Line Current:
45.9 A 480 V normal duty) || 40.5 A 380 V heavy duty) || 35.8 A 480 V heavy duty) || 53.3 A 380 V normal duty)
Rohs Exemption Information:
Yes
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Phase:
3 phase
Height:
910 mm
Discrete Output Number:
0
Product Certifications:
CSA || ATEX INERIS || UL || DNV-GL || ABS || TÜV
Apparent Power:
29.8 kVA 480 V heavy duty) || 38.2 kVA 480 V normal duty)
Analogue Input Number:
3
Enclosure Mounting:
wall mounted
Motor Power Kw:
22 kW heavy duty) || 30 kW normal duty)
Relay Output Number:
3
Operating Altitude:
1000...4800 m with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Prospective Line Isc:
50 kA
Braking To Standstill:
by DC injection
Mercury Free:
Yes
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Input Compatibility:
DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2 || DI1...DI6 discrete input level 1 PLC IEC 61131-2
Variant:
standard version
Vibration Resistance:
1 gn 13-200 Hz)IEC 60068-2-6 || 1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Transmission Frame:
RTU
Sampling Duration:
5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output || 2 ms +/- 0.5 ms DI1...DI4) - discrete input
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Protection Type:
safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || m
Relay Output Type:
configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles || configurable relay logic R1 fault relay NO/NC 100000 cycles
Noise Level:
69.7 dB
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Ambient Air Temperature For Operation:
40-50 °C with derating factor) || -15-40 °C without derating)
Device Short Name:
ATV650
Supply Frequency:
50...60 Hz - 5...5 %
Asynchronous Motor Control Profile:
variable torque standard || constant torque standard
Depth:
340 mm
Overvoltage Category:
III
Standards:
IEC 61800-3 environment 1 category C2 || EN/IEC 61800-3 environment 2 category C3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1 || UL 508C
Frequency Resolution:
analog input 0.012/50 Hz || display unit 0.1 Hz
Maximum Transient Current:
69.5 A 60 s normal duty) || 67.7 A 60 s heavy duty)
Brochure:
View
Catalog:
View
Datasheet:
View
$7,289.49

Description

variable speed drive, Altivar Process ATV600, ATV650, 30kW, 40hp, 380 to 480V, IP55, UL type 12