Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Communication Port Protocol:
Modbus TCP || Modbus serial || EtherNet/IP
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Height:
420 mm
Ambient Air Temperature For Storage:
-40-70 °C
With Safety Function Safe Direction (Sdi):
FALSE
China Rohs Regulation:
X
Product Destination:
asynchronous motors || synchronous motors
Variant:
standard version || with braking chopper
Discrete Output Number:
2
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Base Load Current At Low Overload:
24.0 A
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Net Weight:
22 kg
Discrete Input Logic:
16 preset speeds
Assembly Style:
enclosed
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Relative Symmetric Network Frequency Tolerance:
0.05
Brake Chopper Integrated:
TRUE
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Marking:
CE
Base Load Current At High Overload:
18.0 A
Network Frequency:
50-60 Hz
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 6...10 mm² AWG 10...AWG 8 || DC bus screw terminal 6...10 mm² AWG 10...AWG 8 || line side screw terminal 6...10 mm² AWG 10...AWG 8
With Safety Function Safe Position (Sp):
FALSE
Range Of Product:
Altivar Process ATV900
Product Specific Application:
process for industrial
Type Of Polarization:
no impedance
With Safety Function Safe Operating Stop (Sos):
FALSE
Circularity Profile:
ENVEOLI1704001EN
Upgradeability:
Upgraded components available
With Safety Function Safe Torque Off (Sto):
TRUE
Environmental Disclosure:
ENVPEP1704001EN
Local Signalling:
local diagnostic 3 LED mono/dual colour) || presence of voltage 1 LED red) || embedded communication status 3 LED dual colour) || communication module status 4 LED dual colour)
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Number Of Addresses:
1-247
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Maximum Output Voltage:
690.0 V
Phase:
3 phase
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Mounting Mode:
wall mount
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Product Certifications:
CSA || UL || TÜV
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Mercury Free:
Yes
Analogue Input Number:
3
Maximum Output Frequency:
599 Hz
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Product Or Component Type:
variable speed drive
Connector Type:
2 RJ45 || 1 RJ45
Device Application:
Industrial Application
With Safety Function Safe Stop 1 (Ss1):
TRUE
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Apparent Power:
27.5 kVA 690 V normal duty) || 22.9 kVA 690 V heavy duty)
Power Dissipation In W:
forced convection 376 W 500 V 4 kHz || natural convection 124 W 500 V 4 kHz
Relay Output Number:
3
Ip Degree Of Protection:
IP21
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Data Format:
8 bits, configurable odd, even or no parity
Emc Filter:
integrated || with EMC plate option
Method Of Access:
slave Modbus TCP
Analogue Output Number:
2
Pollution Degree:
2
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Depth:
242 mm
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Volume Of Cooling Air:
330 m3/h
Discrete Input Number:
10
Maximum Transient Current:
27 A 60 s heavy duty) || 28.8 A 60 s normal duty)
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Degree Of Protection:
UL type 1
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Regulation Loop:
adjustable PID regulator
4 Quadrant Operation Possible:
TRUE
Transmission Frame:
RTU
Braking To Standstill:
by DC injection
Quantity Per Set:
1
Motor Power Kw:
15.0 kW normal duty || 11.0 kW heavy duty
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Switching Frequency:
2...8 kHz adjustable || 4...8 kHz with derating factor
Noise Level:
58 dB 86/188/EEC
With Safety Function Safely Limited Speed (Sls):
TRUE
Overvoltage Category:
III
Sustainable Offer Status:
Green Premium product
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
[Us] Rated Supply Voltage:
500...690 V - 15...10 %
Asynchronous Motor Control Profile:
optimized torque mode || constant torque standard || variable torque standard
Operating Position:
vertical +/- 10 degree
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Type Of Polarization:
no impedance Modbus serial
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
With Safety Function Safely Limited Position (Slp):
FALSE
Motor Slip Compensation:
can be suppressed || adjustable || not available in permanent magnet motor law || automatic whatever the load
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Line Current:
23.1 A 500 V normal duty) || 18.4 A 500 V heavy duty) || 23.0 A 690 V normal duty) || 19.2 A 690 V heavy duty)
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Width:
246 mm
Number Of Addresses:
1-247 Modbus serial
Prospective Line Isc:
70 kA
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s || S, U or customized
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immu
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
With Safety Function Safe Programmable Logic:
FALSE
Continuous Output Current:
18 A 4 kHz heavy duty || 24 A 4 kHz normal duty
Ambient Air Transport Temperature:
-40-70 °C
Noise Level:
58 dB
Physical Interface:
Ethernet || 2-wire RS 485
Isolation:
between power and control terminals
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Rohs Exemption Information:
Yes
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Nominal Switching Frequency:
4 kHz