Schneider Electric

Schneider Electric ATV930U22M3 Atv930 Ip21 2,2Kw 200V/240V Variable Spe

(No reviews yet) Write a Review
SKU:
ATV930U22M3
UPC:
3606480883569
Condition:
New
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Motor Power Kw:
2.2 kW normal duty || 1.5 kW heavy duty
Apparent Power:
3 kVA 240 V normal duty) || 2.2 kVA 240 V heavy duty)
Local Signalling:
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Circularity Profile:
ENVEOLI1501005EN
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Sustainable Offer Status:
Green Premium product
Pollution Degree:
2
Discrete Input Number:
10
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Number Of Addresses:
1-247
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Width:
144 mm
Ambient Air Temperature For Storage:
-40-70 °C
Line Current:
8.4 A 200 V normal duty) || 6.0 A 200 V heavy duty) || 7.2 A 240 V normal duty) || 5.3 A 240 V heavy duty)
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Degree Of Protection:
UL type 1
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
With Safety Function Safe Torque Off (Sto):
TRUE
[Us] Rated Supply Voltage:
200...240 V - 15...10 %
Marking:
CE
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
With Safety Function Safely Limited Position (Slp):
FALSE
Noise Level:
54.5 dB 86/188/EEC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ambient Air Transport Temperature:
-40-70 °C
Ip Degree Of Protection:
IP21
Mounting Mode:
wall mount
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Overvoltage Category:
III
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Motor Slip Compensation:
not available in permanent magnet motor law || can be suppressed || adjustable || automatic whatever the load
With Safety Function Safe Programmable Logic:
FALSE
Type Of Polarization:
no impedance Modbus serial
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Phase:
3 phase
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Product Certifications:
UL || CSA || TÜV
4 Quadrant Operation Possible:
TRUE
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Assembly Style:
enclosed
Asynchronous Motor Control Profile:
optimized torque mode || variable torque standard || constant torque standard
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Product Destination:
asynchronous motors || synchronous motors
Brake Chopper Integrated:
TRUE
Continuous Output Current:
11.2 A 4 kHz normal duty || 8 A 4 kHz heavy duty
Method Of Access:
slave Modbus TCP
With Safety Function Safe Stop 1 (Ss1):
TRUE
Range Of Product:
Altivar Process ATV900
Quantity Per Set:
1
Data Format:
8 bits, configurable odd, even or no parity
Connector Type:
2 RJ45 || 1 RJ45
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Regulation Loop:
adjustable PID regulator
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Maximum Transient Current:
13.4 A 60 s normal duty) || 12 A 60 s heavy duty)
Mercury Free:
Yes
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
With Safety Function Safe Direction (Sdi):
FALSE
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Transmission Frame:
RTU
China Rohs Regulation:
X
Power Dissipation In W:
natural convection 32 W 200 V 4 kHz || forced convection 74 W 200 V 4 kHz
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Emc Filter:
integrated || with EMC plate option
Network Frequency:
50-60 Hz
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Relay Output Number:
3
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Physical Interface:
Ethernet || 2-wire RS 485
Analogue Input Number:
3
Discrete Output Number:
2
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Noise Level:
54.5 dB
Braking To Standstill:
by DC injection
Maximum Output Voltage:
240.0 V
Isolation:
between power and control terminals
Base Load Current At Low Overload:
11.2 A
Number Of Addresses:
1-247 Modbus serial
Nominal Switching Frequency:
4 kHz
Volume Of Cooling Air:
38 m3/h
Variant:
with braking chopper || standard version
With Safety Function Safe Operating Stop (Sos):
FALSE
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Operating Position:
vertical +/- 10 degree
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Analogue Output Number:
2
Base Load Current At High Overload:
8.0 A
Communication Port Protocol:
Modbus serial || EtherNet/IP || Modbus TCP
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Product Specific Application:
process for industrial
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Depth:
206 mm
Device Application:
Industrial Application
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Prospective Line Isc:
50 kA
Environmental Disclosure:
ENVPEP1501005EN
Maximum Thdi:
<48 % full load IEC 61000-3-12
Maximum Output Frequency:
599 Hz
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
With Safety Function Safely Limited Speed (Sls):
TRUE
With Safety Function Safe Position (Sp):
FALSE
Product Or Component Type:
variable speed drive
Rohs Exemption Information:
Yes
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 2.5...6 mm² AWG 14...AWG 10 || motor screw terminal 2.5...6 mm² AWG 14...AWG 10 || DC bus screw terminal 2.5...6 mm² AWG 14...AWG 10
Type Of Polarization:
no impedance
Net Weight:
4.5 kg
Height:
350 mm
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Relative Symmetric Network Frequency Tolerance:
0.05
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Discrete Input Logic:
16 preset speeds
Upgradeability:
Upgraded components available
Brochure:
View
Catalog:
View
Datasheet:
View
$1,801.69

Description

This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 2.2kW/3HP for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 1.5kW/2HP for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 200Vac to 240Vac. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments: oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures.
View AllClose