Schneider Electric ATV930U22Y6 Atv930Ip00 2,2Kw 500V-690V Variable Spe
SKU:
ATV930U22Y6
UPC:
3.60648E+12
MPN:
Condition:
New
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Braking To Standstill:
by DC injection
Motor Slip Compensation:
automatic whatever the load || adjustable || can be suppressed || not available in permanent magnet motor law
Nominal Switching Frequency:
4 kHz
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Local Signalling:
local diagnostic 3 LED mono/dual colour) || presence of voltage 1 LED red) || embedded communication status 3 LED dual colour) || communication module status 4 LED dual colour)
Overvoltage Category:
III
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Apparent Power:
4.3 kVA 690 V normal duty) || 3.1 kVA 690 V heavy duty)
Degree Of Protection:
UL type 1
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Connector Type:
2 RJ45 || 1 RJ45
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Communication Port Protocol:
EtherNet/IP || Modbus serial || Modbus TCP
Prospective Line Isc:
70 kA
Circularity Profile:
ENVEOLI1704001EN
Analogue Input Number:
3
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Product Specific Application:
process for industrial
Range Of Product:
Altivar Process ATV900
Environmental Disclosure:
ENVPEP1704001EN
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Asynchronous Motor Control Profile:
variable torque standard || optimized torque mode || constant torque standard
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Device Application:
Industrial Application
Base Load Current At Low Overload:
3.1 A
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Phase:
3 phase
With Safety Function Safe Torque Off (Sto):
TRUE
Relative Symmetric Network Frequency Tolerance:
0.05
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Emc Filter:
integrated || with EMC plate option
Mercury Free:
Yes
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Power Dissipation In W:
forced convection 43 W 500 V 4 kHz || natural convection 73 W 500 V 4 kHz
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Width:
246 mm
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Marking:
CE
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Rohs Exemption Information:
Yes
Depth:
242 mm
Upgradeability:
Upgraded components available
Data Format:
8 bits, configurable odd, even or no parity
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Line Current:
3.4 A 500 V normal duty) || 2.6 A 500 V heavy duty) || 3.6 A 690 V normal duty) || 2.6 A 690 V heavy duty)
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Regulation Loop:
adjustable PID regulator
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Switching Frequency:
2...8 kHz adjustable || 4...8 kHz with derating factor
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Product Certifications:
TÃV || UL || CSA
With Safety Function Safe Position (Sp):
FALSE
Net Weight:
22 kg
Motor Power Kw:
1.5 kW normal duty || 1.1 kW heavy duty
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Analogue Output Number:
2
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Quantity Per Set:
1
Pollution Degree:
2
Base Load Current At High Overload:
2.4 A
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Relay Output Number:
3
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Discrete Input Logic:
16 preset speeds
Ambient Air Temperature For Storage:
-40-70 °C
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || DC bus screw terminal 4...10 mm² AWG 12...AWG 8 || line side screw terminal 4...10 mm² AWG 12...AWG 8 || motor screw terminal 4...10 mm² AWG 12...AWG 8
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Product Destination:
synchronous motors || asynchronous motors
Acceleration And Deceleration Ramps:
S, U or customized || linear adjustable separately from 0.01...9999 s
With Safety Function Safely Limited Position (Slp):
This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. This variable speed drive features an integrated EMC filter with 25m cable conforming to...