Schneider Electric ATV930U40N4ZU Atv930 T12 Rdy Ip20 5Hp 400V Wo Keypad

(No reviews yet) Write a Review
SKU:
ATV930U40N4ZU
UPC:
3606489740221
Condition:
New
With Sft Fct Safe Stop 2 (Ss2):
FALSE
With Safety Function Safe Torque Off (Sto):
TRUE
Relay Output Number:
3
Upgradeability:
Upgraded components available
Product Destination:
synchronous motors || asynchronous motors
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
With Safety Function Safe Programmable Logic:
FALSE
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Height:
285 mm
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Number Of Addresses:
1-247
Discrete Output Number:
2
Noise Level:
54.5 dB
Device Application:
Industrial Application
Discrete Input Number:
10
Rohs Exemption Information:
Yes
China Rohs Regulation:
X
Braking To Standstill:
by DC injection
Analogue Output Number:
2
Environmental Disclosure:
ENVPEP2007009EN
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Base Load Current At High Overload:
7.2 A
Network Frequency:
50-60 Hz
Sustainable Offer Status:
Green Premium product
Discrete Input Logic:
16 preset speeds
Motor Power Kw:
4.0 kW normal duty || 3.0 kW heavy duty
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Apparent Power:
5.6 kVA 480 V normal duty) || 4.5 kVA 480 V heavy duty)
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Maximum Thdi:
<48 % full load IEC 61000-3-12
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Isolation:
between power and control terminals
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Motor Slip Compensation:
not available in permanent magnet motor law || can be suppressed || adjustable || automatic whatever the load
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Phase:
3 phase
Number Of Addresses:
1-247 Modbus serial
Continuous Output Current:
9.3 A 4 kHz normal duty || 7.2 A 4 kHz heavy duty
With Safety Function Safely Limited Speed (Sls):
TRUE
Analogue Input Number:
3
Mercury Free:
Yes
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Brake Chopper Integrated:
TRUE
Base Load Current At Low Overload:
9.3 A
Prospective Line Isc:
50 kA
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Noise Level:
54.5 dB 86/188/EEC
Type Of Polarization:
no impedance Modbus serial
Line Current:
7.6 A 380 V normal duty) || 6.0 A 380 V heavy duty) || 6.7 A 480 V normal duty) || 5.4 A 480 V heavy duty)
With Safety Function Safe Operating Stop (Sos):
FALSE
Volume Of Cooling Air:
38 m3/h
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
With Safety Function Safely Limited Position (Slp):
FALSE
With Safety Function Safe Position (Sp):
FALSE
Degree Of Protection:
UL type 12
4 Quadrant Operation Possible:
TRUE
Quantity Per Set:
1
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Nominal Switching Frequency:
4 kHz
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Type Of Polarization:
no impedance
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Operating Position:
vertical +/- 10 degree
Assembly Style:
with heat sink
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Emc Filter:
integrated || with EMC plate option
Communication Port Protocol:
Modbus serial || Modbus TCP || EtherNet/IP
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Method Of Access:
slave Modbus TCP
Width:
130 mm
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Circularity Profile:
ENVEOLI2007009EN
Transmission Frame:
RTU
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Range Of Product:
Altivar Process ATV900
Marking:
CE
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Ambient Air Transport Temperature:
-40-70 °C
With Safety Function Safe Stop 1 (Ss1):
TRUE
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Product Specific Application:
process for industrial
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Maximum Transient Current:
11.2 A 60 s normal duty) || 10.8 A 60 s heavy duty)
Regulation Loop:
adjustable PID regulator
Physical Interface:
Ethernet || 2-wire RS 485
Product Certifications:
CSA || UL || TÜV
Local Signalling:
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
Maximum Output Frequency:
599 Hz
Ip Degree Of Protection:
IP21
Power Dissipation In W:
natural convection 33 W 380 V 4 kHz || forced convection 97 W 380 V 4 kHz
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Asynchronous Motor Control Profile:
optimized torque mode || constant torque standard || variable torque standard
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Ambient Air Temperature For Storage:
-40-70 °C
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Depth:
196 mm
Overvoltage Category:
III
Maximum Output Voltage:
480.0 V
With Safety Function Safe Direction (Sdi):
FALSE
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Data Format:
8 bits, configurable odd, even or no parity
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Mounting Mode:
cabinet mount
Pollution Degree:
2
Connector Type:
2 RJ45 || 1 RJ45
Variant:
standard version || with braking chopper
Relative Symmetric Network Frequency Tolerance:
0.05
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 2.5...6 mm² AWG 14...AWG 10 || motor screw terminal 2.5...6 mm² AWG 14...AWG 10 || DC bus screw terminal 2.5...6 mm² AWG 14...AWG 10
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Product Or Component Type:
variable speed drive
Datasheet:
View
$1,895.78

Description

variable speed drive, Altivar Process ATV900, ATV930, 5hp, 380 to 480V, cabinet Integration, IP20, for US
View AllClose