Schneider Electric BDA160401 Molded Case Circuit Breaker 347V 40A

(No reviews yet) Write a Review
SKU:
BDA160401
UPC:
3606481151056
Condition:
New
Range:
PowerPact
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Breaking Capacity Code:
D
Mounting Height:
38.1 mm
Halogen Content Performance:
Halogen free product
Quality Labels:
CE
Net Weight:
0.6375 kg
Height:
137 mm
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Control Type:
toggle
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Ambient Air Temperature For Storage:
-50-85 °C
Device Short Name:
BD 040
Network Frequency:
50/60 Hz
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Circuit Breaker Application:
HACR rated
Quantity Per Set:
set of 1
Poles Description:
1P
Local Signalling:
presence of auxiliary contacts flag green)
Environmental Disclosure:
ENVPEP1610005EN
Phase Connection:
A
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Utilisation Category:
category A
Pvc Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Name:
PowerPact B
Sustainable Offer Status:
Green Premium product
Device Application:
distribution
Pollution Degree:
3 IEC 60947-1
Width:
27 mm
Line Rated Current:
40-40 A
Ik Degree Of Protection:
IK07 IEC 62262
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Rohs Exemption Information:
Yes
Wire Stripping Length:
20 mm
Circularity Profile:
N/A
9 Mm Pitches:
3
Trip Unit Technology:
thermal-magnetic
Color:
Gray RAL 7016)
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480Y/277 V AC 50/60 Hz UL 489 || 14 kA 125 V DC 50/60 Hz UL 489 || 10 kA 600/347 V AC 50/60 Hz UL 489
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Mercury Free:
Yes
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Ip Degree Of Protection:
front cover IP40 IEC 60529
[Ue] Rated Operational Voltage:
240 V AC 50/60 Hz UL 489
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Suitability For Isolation:
yes IEC 60947-2
Standards:
CSA C22.2 No 5 || EN/IEC 60947-5-1 || NEMA AB1 || UL 489 || GB 14048.2 || NMX J-266 || EN/IEC 60947-2
Product Or Component Type:
circuit breaker
Ambient Air Temperature For Operation:
-25-70 °C
Connection Pitch:
27 mm
Depth:
89 mm
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Electrical Connection:
I-Line connection, line || lugs, load
Mounting Mode:
I-Line
Continuous Current Rating:
0.8
  • Schneider Electric BDA160401 Molded Case Circuit Breaker 347V 40A
  • Schneider Electric BDA160401 Molded Case Circuit Breaker 347V 40A
  • Schneider Electric BDA160401 Molded Case Circuit Breaker 347V 40A
$365.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 40A, 1 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with an A phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose