Schneider Electric BDA24040Y2 Molded Case Circuit Brkr 480Y/277V 40A

(No reviews yet) Write a Review
SKU:
BDA24040Y2
UPC:
3606481151834
Condition:
New
Ambient Air Temperature For Operation:
-25-70 °C
Control Type:
toggle
Ik Degree Of Protection:
IK07 IEC 62262
Pvc Free:
Yes
Device Application:
distribution
Height:
137 mm
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 10 kA 600Y/347 V AC 50/60 Hz UL 489
Width:
54 mm
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Standards:
UL 489 || EN/IEC 60947-2 || GB 14048.2 || NMX J-266 || CSA C22.2 No 5 || NEMA AB1 || EN/IEC 60947-5-1
Wire Stripping Length:
20 mm
Pollution Degree:
3 IEC 60947-1
Quantity Per Set:
set of 1
Trip Unit Technology:
thermal-magnetic
Range:
PowerPact
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Color:
Gray RAL 7016)
Mounting Mode:
I-Line
Circularity Profile:
N/A
Poles Description:
2P
Mounting Height:
76.2 mm
Network Frequency:
50/60 Hz
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ip Degree Of Protection:
front cover IP40 IEC 60529
Connection Pitch:
27 mm
Product Or Component Type:
circuit breaker
Quality Labels:
CE
Product Name:
PowerPact B
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Continuous Current Rating:
0.8
Circuit Breaker Application:
HACR rated
Halogen Content Performance:
Halogen free product
Device Short Name:
BD 040
Depth:
89 mm
Phase Connection:
AC
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Local Signalling:
presence of auxiliary contacts flag green)
Eu Rohs Directive:
Compliant with Exemptions
Net Weight:
0.952 kg
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Environmental Disclosure:
ENVPEP1610005EN
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Suitability For Isolation:
yes IEC 60947-2
Utilisation Category:
category A
Breaking Capacity Code:
D
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Ambient Air Temperature For Storage:
-50-85 °C
Mercury Free:
Yes
Rohs Exemption Information:
Yes
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Sustainable Offer Status:
Green Premium product
Electrical Connection:
I-Line connection, line || lugs, load
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
9 Mm Pitches:
6
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Line Rated Current:
40-40 A
  • Schneider Electric BDA24040Y2 Molded Case Circuit Brkr 480Y/277V 40A
  • Schneider Electric BDA24040Y2 Molded Case Circuit Brkr 480Y/277V 40A
  • Schneider Electric BDA24040Y2 Molded Case Circuit Brkr 480Y/277V 40A
$714.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 480Y/277VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 40A, 2 pole, circuit breaker has a breaking capacity of 18kA at 480Y/277VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose