[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Continuous Current Rating:
0.8
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Environmental Disclosure:
ENVPEP1610005EN
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Connection Pitch:
27 mm
Mounting Mode:
I-Line
Standards:
EN/IEC 60947-2 || GB 14048.2 || CSA C22.2 No 5 || NEMA AB1 || EN/IEC 60947-5-1 || NMX J-266 || UL 489
Pvc Free:
Yes
Height:
137 mm
Halogen Content Performance:
Halogen free product
Pollution Degree:
3 IEC 60947-1
Ambient Air Temperature For Operation:
-25-70 °C
Ik Degree Of Protection:
IK07 IEC 62262
Sustainable Offer Status:
Green Premium product
Phase Connection:
AB
Utilisation Category:
category A
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Mounting Height:
76.2 mm
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
Electrical Connection:
I-Line connection, line || lugs, load
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Local Signalling:
presence of auxiliary contacts flag green)
Net Weight:
0.952 kg
Wire Stripping Length:
20 mm
Trip Unit Technology:
thermal-magnetic
Poles Description:
2P
Line Rated Current:
50-50 A
Eu Rohs Directive:
Compliant with Exemptions
Range:
PowerPact
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Breaking Capacity Code:
D
Ip Degree Of Protection:
front cover IP40 IEC 60529
Rohs Exemption Information:
Yes
Product Or Component Type:
circuit breaker
Suitability For Isolation:
yes IEC 60947-2
Color:
Gray RAL 7016)
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
9 Mm Pitches:
6
Device Application:
distribution
Device Short Name:
BD 050
Network Frequency:
50/60 Hz
Quantity Per Set:
set of 1
Ambient Air Temperature For Storage:
-50-85 °C
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Circuit Breaker Application:
HACR rated
Circularity Profile:
N/A
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
Depth:
89 mm
Control Type:
toggle
Product Name:
PowerPact B
Quality Labels:
CE
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 10 kA 600Y/347 V AC 50/60 Hz UL 489
Mercury Free:
Yes
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Width:
54 mm
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
  • Schneider Electric BDA24050Y1 Molded Case Circuit Brkr 480Y/277V 50A
  • Schneider Electric BDA24050Y1 Molded Case Circuit Brkr 480Y/277V 50A
  • Schneider Electric BDA24050Y1 Molded Case Circuit Brkr 480Y/277V 50A
$714.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 480Y/277VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 50A, 2 pole, circuit breaker has a breaking capacity of 18kA at 480Y/277VAC. This circuit breaker has a continuous current rating of 80% with an AB phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose