Schneider Electric BDA260202 Molded Case Circuit Brkr 600Y/347V 20A

(No reviews yet) Write a Review
SKU:
BDA260202
UPC:
3606481152046
Condition:
New
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Line Rated Current:
20-20 A
Ik Degree Of Protection:
IK07 IEC 62262
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Pollution Degree:
3 IEC 60947-1
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Phase Connection:
AC
Standards:
EN/IEC 60947-2 || EN/IEC 60947-5-1 || CSA C22.2 No 5 || NEMA AB1 || UL 489 || GB 14048.2 || NMX J-266
Depth:
89 mm
Halogen Content Performance:
Halogen free product
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
9 Mm Pitches:
6
Electrical Connection:
I-Line connection, line || lugs, load
Circularity Profile:
N/A
Product Name:
PowerPact B
Pvc Free:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ambient Air Temperature For Operation:
-25-70 °C
Quality Labels:
CE
Circuit Breaker Application:
HACR rated
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Trip Unit Technology:
thermal-magnetic
Ip Degree Of Protection:
front cover IP40 IEC 60529
Height:
137 mm
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
Continuous Current Rating:
0.8
Poles Description:
2P
Mercury Free:
Yes
Sustainable Offer Status:
Green Premium product
Mounting Height:
76.2 mm
Device Application:
distribution
Color:
Gray RAL 7016)
Environmental Disclosure:
ENVPEP1610005EN
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Suitability For Isolation:
yes IEC 60947-2
Breaking Capacity Code:
D
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Quantity Per Set:
set of 1
Ambient Air Temperature For Storage:
-50-85 °C
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Mounting Mode:
I-Line
Network Frequency:
50/60 Hz
Width:
54 mm
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Utilisation Category:
category A
Control Type:
toggle
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600Y/347 V AC 50/60 Hz UL 489 || 10 kA 250 V DC UL 489
Local Signalling:
presence of auxiliary contacts flag green)
Connection Pitch:
27 mm
Range:
PowerPact
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Product Or Component Type:
circuit breaker
Device Short Name:
BD 020
Rohs Exemption Information:
Yes
Wire Stripping Length:
20 mm
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Net Weight:
0.952 kg
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric BDA260202 Molded Case Circuit Brkr 600Y/347V 20A
  • Schneider Electric BDA260202 Molded Case Circuit Brkr 600Y/347V 20A
  • Schneider Electric BDA260202 Molded Case Circuit Brkr 600Y/347V 20A
$809.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 20A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose