Schneider Electric BDA34110Y Molded Case Circuit Brkr 480Y/277V 110A

(No reviews yet) Write a Review
SKU:
BDA34110Y
UPC:
3606489779177
Condition:
New
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Wire Stripping Length:
20 mm
Halogen Content Performance:
Halogen free product
Continuous Current Rating:
0.8
Trip Unit Technology:
thermal-magnetic
Rohs Exemption Information:
Yes
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Quantity Per Set:
set of 1
Line Rated Current:
110-110 A
Product Name:
PowerPact B
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Utilisation Category:
category A
Connection Pitch:
27 mm
Local Signalling:
presence of auxiliary contacts flag green)
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Phase Connection:
ABC
Mounting Mode:
I-Line
Breaking Capacity Code:
D
9 Mm Pitches:
9
Height:
137 mm
Poles Description:
3P
Quality Labels:
CE
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
Electrical Connection:
I-Line connection, line || lugs, load
Net Weight:
1.315 kg
Network Frequency:
50/60 Hz
Eu Rohs Directive:
Compliant with Exemptions
Device Short Name:
BD 110
Ik Degree Of Protection:
IK07 IEC 62262
Pollution Degree:
3 IEC 60947-1
Pvc Free:
Yes
Product Or Component Type:
circuit breaker
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Depth:
89 mm
Mercury Free:
Yes
Range:
PowerPact
Mounting Height:
114 mm
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Circuit Breaker Application:
HACR rated
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Environmental Disclosure:
ENVPEP1610005EN
Color:
Gray RAL 7016)
Width:
81 mm
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Standards:
UL 489 || EN/IEC 60947-5-1 || GB 14048.2 || CSA C22.2 No 5 || EN/IEC 60947-2 || NEMA AB1 || NMX J-266
Ambient Air Temperature For Storage:
-50-85 °C
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Control Type:
toggle
Device Application:
distribution
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600Y/347 V AC 50/60 Hz UL 489 || 10 kA 250 V DC UL 489
Ambient Air Temperature For Operation:
-25-70 °C
Sustainable Offer Status:
Green Premium product
Suitability For Isolation:
yes IEC 60947-2
Ip Degree Of Protection:
front cover IP40 IEC 60529
Circularity Profile:
N/A
  • Schneider Electric BDA34110Y Molded Case Circuit Brkr 480Y/277V 110A
  • Schneider Electric BDA34110Y Molded Case Circuit Brkr 480Y/277V 110A
  • Schneider Electric BDA34110Y Molded Case Circuit Brkr 480Y/277V 110A
$1,255.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 480Y/277VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 110A, 3 pole, circuit breaker has a breaking capacity of 18kA at 480Y/277VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose