Schneider Electric BDA34125Y Molded Case Circuit Brkr 480Y/277V 125A

(No reviews yet) Write a Review
SKU:
BDA34125Y
UPC:
785901065869
Condition:
New
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Breaking Capacity Code:
D
Depth:
89 mm
Circuit Breaker Application:
HACR rated
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ik Degree Of Protection:
IK07 IEC 62262
Control Type:
toggle
Connection Pitch:
27 mm
Continuous Current Rating:
0.8
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Product Or Component Type:
circuit breaker
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Halogen Content Performance:
Halogen free product
Rohs Exemption Information:
Yes
Ambient Air Temperature For Operation:
-25-70 °C
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Environmental Disclosure:
ENVPEP1610005EN
9 Mm Pitches:
9
Network Frequency:
50/60 Hz
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
Line Rated Current:
125-125 A
Poles Description:
3P
Product Name:
PowerPact B
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ambient Air Temperature For Storage:
-50-85 °C
Color:
Gray RAL 7016)
Circularity Profile:
N/A
Utilisation Category:
category A
Device Short Name:
BD 125
Phase Connection:
ABC
Device Application:
distribution
Range:
PowerPact
Mercury Free:
Yes
Quality Labels:
CE
Pollution Degree:
3 IEC 60947-1
Ip Degree Of Protection:
front cover IP40 IEC 60529
Local Signalling:
presence of auxiliary contacts flag green)
Trip Unit Technology:
thermal-magnetic
Mounting Height:
114 mm
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Net Weight:
1.315 kg
Eu Rohs Directive:
Compliant with Exemptions
Wire Stripping Length:
20 mm
Width:
81 mm
Mounting Mode:
I-Line
Quantity Per Set:
set of 1
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Suitability For Isolation:
yes IEC 60947-2
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
Standards:
UL 489 || GB 14048.2 || NMX J-266 || NEMA AB1 || EN/IEC 60947-2 || CSA C22.2 No 5 || EN/IEC 60947-5-1
Sustainable Offer Status:
Green Premium product
Pvc Free:
Yes
Electrical Connection:
I-Line connection, line || lugs, load
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600Y/347 V AC 50/60 Hz UL 489 || 10 kA 250 V DC UL 489
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Height:
137 mm
  • Schneider Electric BDA34125Y Molded Case Circuit Brkr 480Y/277V 125A
  • Schneider Electric BDA34125Y Molded Case Circuit Brkr 480Y/277V 125A
  • Schneider Electric BDA34125Y Molded Case Circuit Brkr 480Y/277V 125A
$1,360.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 480Y/277VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 125A, 3 pole, circuit breaker has a breaking capacity of 18kA at 480Y/277VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose