Schneider Electric BDA36020 Molded Case Circuit Brkr 600Y/347V 20A

(No reviews yet) Write a Review
SKU:
BDA36020
UPC:
3606481152510
Condition:
New
Electrical Connection:
I-Line connection, line || lugs, load
Wire Stripping Length:
20 mm
Ip Degree Of Protection:
front cover IP40 IEC 60529
Local Signalling:
presence of auxiliary contacts flag green)
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Suitability For Isolation:
yes IEC 60947-2
Ik Degree Of Protection:
IK07 IEC 62262
Network Frequency:
50/60 Hz
Halogen Content Performance:
Halogen free product
Rohs Exemption Information:
Yes
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
Height:
137 mm
Product Name:
PowerPact B
Connection Pitch:
27 mm
Phase Connection:
ABC
Net Weight:
1.315 kg
Quality Labels:
CE
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Ambient Air Temperature For Operation:
-25-70 °C
Color:
Gray RAL 7016)
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
Trip Unit Technology:
thermal-magnetic
Control Type:
toggle
Product Or Component Type:
circuit breaker
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Device Short Name:
BD 020
Sustainable Offer Status:
Green Premium product
Eu Rohs Directive:
Compliant with Exemptions
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Line Rated Current:
20-20 A
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Continuous Current Rating:
0.8
Mounting Mode:
I-Line
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Ambient Air Temperature For Storage:
-50-85 °C
Mercury Free:
Yes
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Depth:
89 mm
Standards:
UL 489 || EN/IEC 60947-2 || EN/IEC 60947-5-1 || CSA C22.2 No 5 || GB 14048.2 || NEMA AB1 || NMX J-266
Device Application:
distribution
Range:
PowerPact
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600Y/347 V AC 50/60 Hz UL 489 || 10 kA 250 V DC UL 489
Utilisation Category:
category A
9 Mm Pitches:
9
Environmental Disclosure:
ENVPEP1610005EN
Breaking Capacity Code:
D
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Pollution Degree:
3 IEC 60947-1
Mounting Height:
114 mm
Width:
81 mm
Poles Description:
3P
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Pvc Free:
Yes
Circuit Breaker Application:
HACR rated
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Quantity Per Set:
set of 1
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile:
N/A
  • Schneider Electric BDA36020 Molded Case Circuit Brkr 600Y/347V 20A
  • Schneider Electric BDA36020 Molded Case Circuit Brkr 600Y/347V 20A
  • Schneider Electric BDA36020 Molded Case Circuit Brkr 600Y/347V 20A
$1,012.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 20A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose