Schneider Electric BDA36040 Molded Case Circuit Brkr 600Y/347V 40A

(No reviews yet) Write a Review
SKU:
BDA36040
UPC:
3606481152596
Condition:
New
Circuit Breaker Application:
HACR rated
Ambient Air Temperature For Operation:
-25-70 °C
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Ambient Air Temperature For Storage:
-50-85 °C
Mercury Free:
Yes
9 Mm Pitches:
9
Height:
137 mm
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Device Short Name:
BD 040
Poles Description:
3P
Sustainable Offer Status:
Green Premium product
Quality Labels:
CE
Product Name:
PowerPact B
Eu Rohs Directive:
Compliant with Exemptions
Utilisation Category:
category A
Circularity Profile:
N/A
Depth:
89 mm
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Quantity Per Set:
set of 1
Control Type:
toggle
Standards:
EN/IEC 60947-5-1 || NMX J-266 || GB 14048.2 || NEMA AB1 || EN/IEC 60947-2 || UL 489 || CSA C22.2 No 5
Network Frequency:
50/60 Hz
Ip Degree Of Protection:
front cover IP40 IEC 60529
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600Y/347 V AC 50/60 Hz UL 489 || 10 kA 250 V DC UL 489
Mounting Mode:
I-Line
Local Signalling:
presence of auxiliary contacts flag green)
Rohs Exemption Information:
Yes
Width:
81 mm
Pollution Degree:
3 IEC 60947-1
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mounting Height:
114 mm
Pvc Free:
Yes
Ik Degree Of Protection:
IK07 IEC 62262
Connection Pitch:
27 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Halogen Content Performance:
Halogen free product
Range:
PowerPact
Line Rated Current:
40-40 A
Continuous Current Rating:
0.8
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Environmental Disclosure:
ENVPEP1610005EN
Phase Connection:
ABC
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Trip Unit Technology:
thermal-magnetic
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Device Application:
distribution
Suitability For Isolation:
yes IEC 60947-2
Breaking Capacity Code:
D
Net Weight:
1.315 kg
Color:
Gray RAL 7016)
Wire Stripping Length:
20 mm
Product Or Component Type:
circuit breaker
Electrical Connection:
I-Line connection, line || lugs, load
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric BDA36040 Molded Case Circuit Brkr 600Y/347V 40A
  • Schneider Electric BDA36040 Molded Case Circuit Brkr 600Y/347V 40A
  • Schneider Electric BDA36040 Molded Case Circuit Brkr 600Y/347V 40A
$1,012.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 40A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose