Schneider Electric BDF26015 Molded Case Circuit Brkr 600Y/347V 15A
Schneider Electric
$783.00
PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit has terminal nuts on both termination ends. This PowerPacT B, 15A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked. Optional terminations.
- Rohs Exemption Information:
- Yes
- Ik Degree Of Protection:
- IK07 IEC 62262
- Net Weight:
- 0.669 kg
- 9 Mm Pitches:
- 6
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Product Certifications:
- UL || IEC || CCC || EAC || CSA || NOM
- Mounting Mode:
- clip-on 35 mm symmetrical DIN rail) || by screws plate)
- [Ui] Rated Insulation Voltage:
- 800 V IEC 60947-2
- Network Frequency:
- 50/60 Hz
- Product Name:
- PowerPact B
- Sustainable Offer Status:
- Green Premium product
- Ambient Air Temperature For Storage:
- -50-85 °C
- Mechanical Durability:
- 15000 cycles IEC 947-1 Annex K ed 5.2
- Suitability For Isolation:
- yes IEC 60947-2
- Device Application:
- distribution
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Breaking Capacity:
- 25 kA 208Y/120 V AC 50/60 Hz UL 489 || 18 kA 240 V AC 50/60 Hz UL 489 || Icu 25 kA 480/277 V AC 50/60 Hz UL 489 || Icu 14 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600Y/347 V AC 50/60 Hz UL 489 || 14 kA 250 V DC UL 489 || 25 kA || Icu 18 kA
- Halogen Content Performance:
- Halogen free product
- Utilisation Category:
- category A
- Device Short Name:
- BD 015
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Number Of Slots:
- 1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
- Standards:
- EN/IEC 60947-2 || NEMA AB1 || EN/IEC 60947-5-1 || NMX J-266 || UL 489 || GB 14048.2 || CSA C22.2 No 5
- [Ue] Rated Operational Voltage:
- 525 V AC 50/60 Hz UL 489
- Control Type:
- toggle
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Wire Stripping Length:
- 20 mm
- Poles Description:
- 2P
- Height:
- 137 mm
- Quantity Per Set:
- set of 1
- Color:
- Gray RAL 7016)
- Eu Rohs Directive:
- Compliant with Exemptions
- Connection Pitch:
- 27 mm
- Range:
- PowerPact
- Environmental Disclosure:
- ENVPEP1610005EN
- Depth:
- 80 mm
- Tightening Torque:
- 5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
- Circuit Breaker Application:
- HACR rated
- Awg Gauge:
- AWG 14...AWG 8 aluminium/copper || AWG 6...AWG 3/0 aluminium/copper
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Pvc Free:
- Yes
- Quality Labels:
- CE
- Pollution Degree:
- 3 IEC 60947-1
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Ambient Air Temperature For Operation:
- -25-70 °C
- Breaking Capacity Code:
- D
- Local Signalling:
- presence of auxiliary contacts flag green)
- Width:
- 54 mm
- Trip Unit Technology:
- thermal-magneticTM-D,
- Protected Poles Description:
- 2t
- Circularity Profile:
- N/A
- Continuous Current Rating:
- 0.8
- Trip Unit Name:
- TM-D
- Operating Altitude:
- 6561.68 ft (2000 m) without derating || 5000 m with derating
- Product Or Component Type:
- circuit breaker
- Mercury Free:
- Yes
- Electrical Connection:
- terminal nut, ON and OFF end
- Electrical Durability:
- 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- Line Rated Current:
- 15-15 A
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View