Schneider Electric BDF26060 Molded Case Circuit Brkr 600Y/347V 60A

(No reviews yet) Write a Review
SKU:
BDF26060
UPC:
3606481148988
Condition:
New
Protected Poles Description:
2t
Local Signalling:
presence of auxiliary contacts flag green)
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Mercury Free:
Yes
Control Type:
toggle
Device Application:
distribution
Halogen Content Performance:
Halogen free product
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Trip Unit Technology:
thermal-magneticTM-D,
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 18 kA 240 V AC 50/60 Hz UL 489 || Icu 25 kA 480/277 V AC 50/60 Hz UL 489 || Icu 14 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600Y/347 V AC 50/60 Hz UL 489 || 14 kA 250 V DC UL 489 || 25 kA || Icu 18 kA
Ik Degree Of Protection:
IK07 IEC 62262
Breaking Capacity Code:
D
Rohs Exemption Information:
Yes
Suitability For Isolation:
yes IEC 60947-2
Net Weight:
0.669 kg
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Operating Altitude:
6561.68 ft (2000 m) without derating || 5000 m with derating
Device Short Name:
BD 060
Awg Gauge:
AWG 14...AWG 8 aluminium/copper || AWG 6...AWG 3/0 aluminium/copper
Ambient Air Temperature For Operation:
-25-70 °C
Trip Unit Name:
TM-D
9 Mm Pitches:
6
Height:
137 mm
Circuit Breaker Application:
HACR rated
Wire Stripping Length:
20 mm
Ambient Air Temperature For Storage:
-50-85 °C
Width:
54 mm
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Electrical Connection:
terminal nut, ON and OFF end
Network Frequency:
50/60 Hz
Connection Pitch:
27 mm
Mechanical Durability:
15000 cycles IEC 947-1 Annex K ed 5.2
Color:
Gray RAL 7016)
Line Rated Current:
60-60 A
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Pvc Free:
Yes
Product Or Component Type:
circuit breaker
Product Name:
PowerPact B
Depth:
80 mm
Ip Degree Of Protection:
front cover IP40 IEC 60529
Utilisation Category:
category A
Range:
PowerPact
Quantity Per Set:
set of 1
Standards:
UL 489 || NMX J-266 || EN/IEC 60947-5-1 || CSA C22.2 No 5 || GB 14048.2 || EN/IEC 60947-2 || NEMA AB1
Mounting Mode:
clip-on 35 mm symmetrical DIN rail) || by screws plate)
Pollution Degree:
3 IEC 60947-1
Continuous Current Rating:
0.8
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Environmental Disclosure:
ENVPEP1610005EN
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Eu Rohs Directive:
Compliant
Quality Labels:
CE
Sustainable Offer Status:
Green Premium product
Poles Description:
2P
  • Schneider Electric BDF26060 Molded Case Circuit Brkr 600Y/347V 60A
  • Schneider Electric BDF26060 Molded Case Circuit Brkr 600Y/347V 60A
  • Schneider Electric BDF26060 Molded Case Circuit Brkr 600Y/347V 60A
$1,174.50

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit has terminal nuts on both termination ends. This PowerPacT B, 60A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked. Optional terminations.
View AllClose