Schneider Electric BDL16125 Molded Case Circuit Breaker 347V 125A

(No reviews yet) Write a Review
SKU:
BDL16125
UPC:
3606481148599
Condition:
New
Breaking Capacity Code:
D
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Trip Unit Technology:
thermal-magneticTM-D,
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Depth:
80 mm
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Height:
137 mm
Standards:
EN/IEC 60947-5-1 || UL 489 || GB 14048.2 || NMX J-266 || CSA C22.2 No 5 || EN/IEC 60947-2 || NEMA AB1
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
9 Mm Pitches:
3
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 In
Control Type:
toggle
Ambient Air Temperature For Storage:
-50-85 °C
Device Short Name:
BD 125
Product Or Component Type:
circuit breaker
Width:
27 mm
Quality Labels:
CE
Product Name:
PowerPact B
Quantity Per Set:
set of 1
Ambient Air Temperature For Operation:
-25-70 °C
Utilisation Category:
category A
Mechanical Durability:
15000 cycles IEC 947-1 Annex F ed 5.2
Operating Altitude:
6561.68 ft (2000 m) without derating || 5000 m with derating
Ik Degree Of Protection:
IK07 IEC 62262
Suitability For Isolation:
yes IEC 60947-2
Connection Pitch:
27 mm
Sustainable Offer Status:
Green Premium product
Range:
PowerPact
Mercury Free:
Yes
Protected Poles Description:
1t
Trip Unit Name:
TM-D
Pollution Degree:
3 IEC 60947-1
Eu Rohs Directive:
Compliant
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Poles Description:
1P
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2
[Ue] Rated Operational Voltage:
240 V AC 50/60 Hz UL 489
Awg Gauge:
AWG 6...AWG 2/0 fine stranded aluminium/copper || AWG 14...AWG 3/0 rigid or stranded aluminium/copper
Line Rated Current:
125-125 A
Rohs Exemption Information:
Yes
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480Y/277 V AC 50/60 Hz UL 489 || 10 kA 125 V DC 50/60 Hz UL 489 || 14 kA 600/347 V AC 50/60 Hz UL 489
Device Application:
distribution
Net Weight:
0.51 kg
Continuous Current Rating:
0.8
Color:
Gray RAL 7016)
Electrical Connection:
Everlink lug, line || Everlink lug, load
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
Halogen Content Performance:
Halogen free product
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Environmental Disclosure:
ENVPEP1610005EN
Wire Stripping Length:
20 mm
Network Frequency:
50/60 Hz
Ip Degree Of Protection:
front cover IP40 IEC 60529
Mounting Mode:
clip-on 35 mm symmetrical DIN rail) || by screws plate)
Pvc Free:
Yes
Circuit Breaker Application:
HACR rated
  • Schneider Electric BDL16125 Molded Case Circuit Breaker 347V 125A
  • Schneider Electric BDL16125 Molded Case Circuit Breaker 347V 125A
  • Schneider Electric BDL16125 Molded Case Circuit Breaker 347V 125A
$940.50

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit features EverLink lugs, a patented design to reduce loosening of cables over time, on both termination ends. This PowerPacT B, 125A, 1 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked. EverLink lugs are also available with unique integrated control wire terminals.
View AllClose