Schneider Electric BDL26100 Molded Case Circuit Brkr 600Y/347V 100A

(No reviews yet) Write a Review
SKU:
BDL26100
UPC:
3606481152923
Condition:
New
Utilisation Category:
category A
Range:
PowerPact
Pvc Free:
Yes
Pollution Degree:
3 IEC 60947-1
Ambient Air Temperature For Operation:
-25-70 °C
Breaking Capacity Code:
D
Quantity Per Set:
set of 1
Rohs Exemption Information:
Yes
Line Rated Current:
100-100 A
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Poles Description:
2P
Eu Rohs Directive:
Compliant with Exemptions
Awg Gauge:
AWG 6...AWG 2/0 fine stranded aluminium/copper || AWG 14...AWG 3/0 rigid or stranded aluminium/copper
Control Type:
toggle
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Halogen Content Performance:
Halogen free product
Height:
137 mm
Ambient Air Temperature For Storage:
-50-85 °C
Circuit Breaker Application:
HACR rated
Depth:
80 mm
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Continuous Current Rating:
0.8
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Or Component Type:
circuit breaker
Product Name:
PowerPact B
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Sustainable Offer Status:
Green Premium product
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Mounting Mode:
clip-on 35 x 15 mm symmetrical DIN rail) || by screws plate)
Suitability For Isolation:
yes IEC 60947-2
9 Mm Pitches:
6
Device Application:
distribution
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600Y/347 V AC 50/60 Hz UL 489 || 10 kA 250 V DC UL 489
Net Weight:
0.769 kg
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Electrical Connection:
Everlink lug, line || Everlink lug, load
Width:
54 mm
Standards:
NMX J-266 || GB 14048.2 || CSA C22.2 No 5 || NEMA AB1 || EN/IEC 60947-2 || EN/IEC 60947-5-1 || UL 489
Color:
Gray RAL 7016)
Ip Degree Of Protection:
front cover IP40 IEC 60529
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Device Short Name:
BD 100
Quality Labels:
CE
Local Signalling:
presence of auxiliary contacts flag green)
Wire Stripping Length:
20 mm
Connection Pitch:
27 mm
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
Trip Unit Technology:
thermal-magnetic
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ik Degree Of Protection:
IK07 IEC 62262
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Mercury Free:
Yes
Network Frequency:
50/60 Hz
Circularity Profile:
N/A
Environmental Disclosure:
ENVPEP1610005EN
  • Schneider Electric BDL26100 Molded Case Circuit Brkr 600Y/347V 100A
  • Schneider Electric BDL26100 Molded Case Circuit Brkr 600Y/347V 100A
  • Schneider Electric BDL26100 Molded Case Circuit Brkr 600Y/347V 100A
$956.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit features EverLink lugs, a patented design to reduce loosening of cables over time, on both termination ends. This PowerPacT B, 100A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.